187 related articles for article (PubMed ID: 22831706)
1. The prediction of CSF gusher in cochlear implants with inner ear abnormality.
Hongjian L; Guangke W; Song M; Xiaoli D; Daoxing Z
Acta Otolaryngol; 2012 Dec; 132(12):1271-4. PubMed ID: 22831706
[TBL] [Abstract][Full Text] [Related]
2. [Possible reasons for cerebrospinal fluid gusher in cochlear implantation with inner ear abnormality].
Sun SP; Lu W; Men XM; Zuo B; Lei YB
Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2017 Apr; 52(4):283-286. PubMed ID: 28441806
[No Abstract] [Full Text] [Related]
3. Cerebrospinal fluid gusher in cochlear implant and its associated factors.
Hashemi SB; Bozorgi H; Kazemi T; Babaei A
Acta Otolaryngol; 2020 Aug; 140(8):621-625. PubMed ID: 32329639
[No Abstract] [Full Text] [Related]
4. Cerebrospinal fluid gusher in cochlear implantation.
Eftekharian A; Amizadeh M
Cochlear Implants Int; 2014 May; 15(3):179-84. PubMed ID: 24660749
[TBL] [Abstract][Full Text] [Related]
5. [The value of HRCT in predicting cerebrospinal fluid gusher during cochlear implantation].
Liu Z; Lin X; Huang H; Dong G; Wu P
Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2024 May; 38(5):421-425. PubMed ID: 38686481
[No Abstract] [Full Text] [Related]
6. [Prediction and management about perilymph gusher in cochlear implantation].
Zhang D; Hu B; Xiao Y; Zheng H
Lin Chuang Er Bi Yan Hou Ke Za Zhi; 2006 Apr; 20(7):295-6, 299. PubMed ID: 16780140
[TBL] [Abstract][Full Text] [Related]
7. Cerebrospinal Fluid Gusher in Cochlear Implantation and Its Association with Inner-Ear Malformations.
Dalgic A; Atsal G; Ceylan ME; Aydın E; Adıbelli ZH; Edizer DT; Olgun L
J Int Adv Otol; 2022 Nov; 18(6):478-481. PubMed ID: 36349668
[TBL] [Abstract][Full Text] [Related]
8. Prediction of Intraoperative CSF Gusher and Postoperative Facial Nerve Stimulation in Patients With Cochleovestibular Malformations Undergoing Cochlear Implantation Surgery.
Kamogashira T; Iwasaki S; Kashio A; Kakigi A; Karino S; Matsumoto Y; Yamasoba T
Otol Neurotol; 2017 Jul; 38(6):e114-e119. PubMed ID: 28475547
[TBL] [Abstract][Full Text] [Related]
9. A Novel Surgical Technique for the Management of Cerebrospinal Fluid Gusher Encountered During Cochlear Implantation.
Tolisano AM; Wick CC; Kutz JW
Otol Neurotol; 2020 Oct; 41(9):e1177. PubMed ID: 32925868
[TBL] [Abstract][Full Text] [Related]
10. CSF gusher in cochlear implantation: The risk of missing CT evidence of a cochlear base defect in the presence of otherwise normal cochlear anatomy.
Cabbarzade C; Sennaroglu L; Süslü N
Cochlear Implants Int; 2015 Jul; 16(4):233-6. PubMed ID: 24986441
[TBL] [Abstract][Full Text] [Related]
11. Novel Computed Tomography Findings Suggestive of Perilymph Gusher.
Varadarajan VV; DeJesus RO; Antonelli PJ
Otol Neurotol; 2018 Sep; 39(8):1066-1069. PubMed ID: 30113567
[TBL] [Abstract][Full Text] [Related]
12. [High-resolution CT findings of inner ear malformations with cerebrospinal fluid leakage].
Chen S; Gong S; Xian J; Zhao S; Yu Z
Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi; 2010 Jul; 24(13):577-9. PubMed ID: 20842942
[TBL] [Abstract][Full Text] [Related]
13. A new cochlear implant electrode with a "cork"-type stopper for inner ear malformations.
Sennaroğlu L; Atay G; Bajin MD
Auris Nasus Larynx; 2014 Aug; 41(4):331-6. PubMed ID: 24560093
[TBL] [Abstract][Full Text] [Related]
14. Influence of an intraoperative perilymph gusher on cochlear implant performance in children with labyrinthine malformations.
Adunka OF; Teagle HF; Zdanski CJ; Buchman CA
Otol Neurotol; 2012 Dec; 33(9):1489-96. PubMed ID: 22996156
[TBL] [Abstract][Full Text] [Related]
15. Management of cerebrospinal fluid leakage from cochleostomy during cochlear implant surgery.
Wootten CT; Backous DD; Haynes DS
Laryngoscope; 2006 Nov; 116(11):2055-9. PubMed ID: 17075411
[TBL] [Abstract][Full Text] [Related]
16. Early complications following cochlear implantation in children and their management.
Li S; Qin Z; Zhang F; Li L; Qi S; Liu L
Int J Pediatr Otorhinolaryngol; 2014 Jul; 78(7):1040-4. PubMed ID: 24809767
[TBL] [Abstract][Full Text] [Related]
17. Cochlear implantation in children with anomalous cochleovestibular anatomy.
Melo AS; Martins J; Silva J; Quadros J; Paiva A
Auris Nasus Larynx; 2017 Oct; 44(5):509-516. PubMed ID: 28442169
[TBL] [Abstract][Full Text] [Related]
18. Cochlear implant and inner ear malformation. Proposal for an hyperosmolar therapy at surgery.
Loundon N; Leboulanger N; Maillet J; Riggouzzo A; Richard P; Marlin S; Garabedian EN
Int J Pediatr Otorhinolaryngol; 2008 Apr; 72(4):541-7. PubMed ID: 18282614
[TBL] [Abstract][Full Text] [Related]
19. Intraoperative CT-guided cochlear implantation in congenital ear deformity.
Yuan YY; Song YS; Chai CM; Shen WD; Han WJ; Liu J; Wang GJ; Dong TX; Han DY; Dai P
Acta Otolaryngol; 2012 Sep; 132(9):951-8. PubMed ID: 22668345
[TBL] [Abstract][Full Text] [Related]
20. Cochlear implantation in 21 patients with common cavity malformation.
Xia J; Wang W; Zhang D
Acta Otolaryngol; 2015 May; 135(5):459-65. PubMed ID: 25677857
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]