These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 22831998)

  • 1. Sensitive determination of trace mercury by UV-visible diffuse reflectance spectroscopy after complexation and membrane filtration-enrichment.
    Yin C; Iqbal J; Hu H; Liu B; Zhang L; Zhu B; Du Y
    J Hazard Mater; 2012 Sep; 233-234():207-12. PubMed ID: 22831998
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dithizone nanofiber-coated membrane for filtration-enrichment and colorimetric detection of trace Hg(II) ion.
    Takahashi Y; Danwittayakul S; Suzuki TM
    Analyst; 2009 Jul; 134(7):1380-5. PubMed ID: 19562205
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Determination of Trace Lead in Water by UV-Visible Diffuse Reflectance Spectroscopy Combined with Surfactant and Membrane Filtration-Enrichment].
    Zhang XF; Zhu BL; Li W; Wang L; Zhang L; Wu T; Du YP
    Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Jul; 35(7):1944-8. PubMed ID: 26717757
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sensitive determination of mercury by a miniaturized spectrophotometer after in situ single-drop microextraction.
    Yang F; Liu R; Tan Z; Wen X; Zheng C; Lv Y
    J Hazard Mater; 2010 Nov; 183(1-3):549-53. PubMed ID: 20696521
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Immersed single-drop microextraction-electrothermal vaporization atomic absorption spectroscopy for the trace determination of mercury in water samples.
    Bagheri H; Naderi M
    J Hazard Mater; 2009 Jun; 165(1-3):353-8. PubMed ID: 19036515
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dithizone-functionalized solid phase extraction-displacement elution-high performance liquid chromatography-inductively coupled plasma mass spectrometry for mercury speciation in water samples.
    Yin YG; Chen M; Peng JF; Liu JF; Jiang GB
    Talanta; 2010 Jun; 81(4-5):1788-92. PubMed ID: 20441974
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Solid phase extraction of ultra traces mercury (II) using octadecyl silica membrane disks modified by 1,3-bis(2-ethoxyphenyl)triazene (EPT) ligand and determination by cold vapor atomic absorption spectrometry.
    Rofouei MK; Sabouri A; Ahmadalinezhad A; Ferdowsi H
    J Hazard Mater; 2011 Sep; 192(3):1358-63. PubMed ID: 21782328
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Part 1. Spectrophotometric determination of trace mercury (II) in dental-unit wastewater and fertilizer samples using the novel reagent 6-hydroxy-3-(2-oxoindolin-3-ylideneamino)-2-thioxo-2H-1,3-thiazin-4(3H)-one and the dual-wavelength beta-correction spectrophotometry.
    Hamza A; Bashammakh AS; Al-Sibaai AA; Al-Saidi HM; El-Shahawi MS
    J Hazard Mater; 2010 Jun; 178(1-3):287-92. PubMed ID: 20149525
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A simple spectrophotometric determination of trace level mercury using 1,5-diphenylthiocarbazone solubilized in micelle.
    Khan H; Ahmed MJ; Bhanger MI
    Anal Sci; 2005 May; 21(5):507-12. PubMed ID: 15913137
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Gold-coated silica as a preconcentration phase for the determination of total dissolved mercury in natural waters using atomic fluorescence spectrometry.
    Leopold K; Foulkes M; Worsfold PJ
    Anal Chem; 2009 May; 81(9):3421-8. PubMed ID: 19334705
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Methionine-pyrene hybrid based fluorescent probe for trace level detection and estimation of Hg(II) in aqueous environmental samples: experimental and computational studies.
    Banerjee A; Karak D; Sahana A; Guha S; Lohar S; Das D
    J Hazard Mater; 2011 Feb; 186(1):738-44. PubMed ID: 21146291
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Solid phase extraction and spectrophotometric determination of mercury by adsorption of its diphenylthiocarbazone complex on an alumina column.
    Rajesh N; Gurulakshmanan G
    Spectrochim Acta A Mol Biomol Spectrosc; 2008 Feb; 69(2):391-5. PubMed ID: 17572137
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cloud point extraction and spectrophotometric determination of mercury species at trace levels in environmental samples.
    Ulusoy Hİ; Gürkan R; Ulusoy S
    Talanta; 2012 Jan; 88():516-23. PubMed ID: 22265535
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A sensitive method for determining total vanadium in water samples using colorimetric-solid-phase extraction-fiber optic reflectance spectroscopy.
    Filik H; Yanaz Z
    J Hazard Mater; 2009 Dec; 172(2-3):1297-302. PubMed ID: 19717227
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Synthesis, characterization and application of poly(acrylamide-co-methylenbisacrylamide) nanocomposite as a colorimetric chemosensor for visual detection of trace levels of Hg and Pb ions.
    Sedghi R; Heidari B; Behbahani M
    J Hazard Mater; 2015 Mar; 285():109-16. PubMed ID: 25497023
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Speciation analysis of mercury in water samples by cold vapor atomic absorption spectrometry after preconcentration with dithizone immobilized on microcrystalline naphthalene.
    Haji Shabani AM; Dadfarnia S; Nasirizadeh N
    Anal Bioanal Chem; 2004 Mar; 378(5):1388-91. PubMed ID: 14735268
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Highly selective and sensitive optical sensor for determination of Pb2+ and Hg2+ ions based on the covalent immobilization of dithizone on agarose membrane.
    Zargoosh K; Babadi FF
    Spectrochim Acta A Mol Biomol Spectrosc; 2015 Feb; 137():105-10. PubMed ID: 25216460
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Neutron activation determination of mercury in waters after preconcentration by flotation of dithizone-mercury complexes.
    Feng X; Ryan DE
    Int J Environ Anal Chem; 1985; 19(4):273-80. PubMed ID: 4008161
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sensitive mercury speciation by reversed-phase column high-performance liquid chromatography with UV-visible detection after solid-phase extraction using 6-mercaptopurine and dithizone.
    Hashemi-Moghaddam H; Saber-Tehrani M
    J AOAC Int; 2008; 91(6):1453-8. PubMed ID: 19202808
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spectrophotometric determination of inorganic mercury (II) after preconcentration of its diphenylthiocarbazone complex on a cellulose column.
    Rajesh N; Hari MS
    Spectrochim Acta A Mol Biomol Spectrosc; 2008 Oct; 70(5):1104-8. PubMed ID: 18083613
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.