These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
344 related articles for article (PubMed ID: 22842678)
1. Monte Carlo modelling of diode detectors for small field MV photon dosimetry: detector model simplification and the sensitivity of correction factors to source parameterization. Cranmer-Sargison G; Weston S; Evans JA; Sidhu NP; Thwaites DI Phys Med Biol; 2012 Aug; 57(16):5141-53. PubMed ID: 22842678 [TBL] [Abstract][Full Text] [Related]
2. Design and experimental testing of air slab caps which convert commercial electron diodes into dual purpose, correction-free diodes for small field dosimetry. Charles PH; Cranmer-Sargison G; Thwaites DI; Kairn T; Crowe SB; Pedrazzini G; Aland T; Kenny J; Langton CM; Trapp JV Med Phys; 2014 Oct; 41(10):101701. PubMed ID: 25281940 [TBL] [Abstract][Full Text] [Related]
3. Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors. Cranmer-Sargison G; Weston S; Evans JA; Sidhu NP; Thwaites DI Med Phys; 2011 Dec; 38(12):6592-602. PubMed ID: 22149841 [TBL] [Abstract][Full Text] [Related]
4. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method. Moignier C; Huet C; Makovicka L Med Phys; 2014 Jul; 41(7):071702. PubMed ID: 24989371 [TBL] [Abstract][Full Text] [Related]
5. Experimental small field 6 MV output ratio analysis for various diode detector and accelerator combinations. Cranmer-Sargison G; Weston S; Sidhu NP; Thwaites DI Radiother Oncol; 2011 Sep; 100(3):429-35. PubMed ID: 21945858 [TBL] [Abstract][Full Text] [Related]
6. Dosimetry of cone-defined stereotactic radiosurgery fields with a commercial synthetic diamond detector. Morales JE; Crowe SB; Hill R; Freeman N; Trapp JV Med Phys; 2014 Nov; 41(11):111702. PubMed ID: 25370616 [TBL] [Abstract][Full Text] [Related]
7. Small field detector correction factors kQclin,Qmsr (fclin,fmsr) for silicon-diode and diamond detectors with circular 6 MV fields derived using both empirical and numerical methods. O'Brien DJ; León-Vintró L; McClean B Med Phys; 2016 Jan; 43(1):411. PubMed ID: 26745934 [TBL] [Abstract][Full Text] [Related]
8. Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields. Czarnecki D; Zink K Phys Med Biol; 2013 Apr; 58(8):2431-44. PubMed ID: 23514734 [TBL] [Abstract][Full Text] [Related]
9. Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: a PENELOPE Monte Carlo study. Benmakhlouf H; Sempau J; Andreo P Med Phys; 2014 Apr; 41(4):041711. PubMed ID: 24694131 [TBL] [Abstract][Full Text] [Related]
10. Spectral distribution of particle fluence in small field detectors and its implication on small field dosimetry. Benmakhlouf H; Andreo P Med Phys; 2017 Feb; 44(2):713-724. PubMed ID: 28032369 [TBL] [Abstract][Full Text] [Related]
11. Monte Carlo-based diode design for correction-less small field dosimetry. Charles PH; Crowe SB; Kairn T; Knight RT; Hill B; Kenny J; Langton CM; Trapp JV Phys Med Biol; 2013 Jul; 58(13):4501-12. PubMed ID: 23760107 [TBL] [Abstract][Full Text] [Related]
12. 6-MV small field output factors: intra-/intermachine comparison and implementation of TRS-483 using various detectors and several linear accelerators. Ghazal M; Westermark M; Kaveckyte V; Carlsson-Tedgren Å; Benmakhlouf H Med Phys; 2019 Nov; 46(11):5350-5359. PubMed ID: 31532831 [TBL] [Abstract][Full Text] [Related]
13. Correction factor measurements for multiple detectors used in small field dosimetry on the Varian Edge radiosurgery system. Tanny S; Sperling N; Parsai EI Med Phys; 2015 Sep; 42(9):5370-6. PubMed ID: 26328986 [TBL] [Abstract][Full Text] [Related]
14. Monte Carlo calculated correction factors for the PTW microDiamond detector in the Gamma Knife-Model C. Barrett JC; Knill C Med Phys; 2016 Mar; 43(3):1035-44. PubMed ID: 26936691 [TBL] [Abstract][Full Text] [Related]
15. Non-reference condition correction factor kNR of typical radiation detectors applied for the dosimetry of high-energy photon fields in radiotherapy. Chofor N; Harder D; Poppe B Z Med Phys; 2012 Sep; 22(3):181-96. PubMed ID: 22658451 [TBL] [Abstract][Full Text] [Related]
16. Field correction factors for a PTW-31016 Pinpoint ionization chamber for both flattened and unflattened beams. Study of the main sources of uncertainties. Puxeu-Vaqué J; Duch MA; Nailon WH; Cruz Lizuain M; Ginjaume M Med Phys; 2017 May; 44(5):1930-1938. PubMed ID: 28261817 [TBL] [Abstract][Full Text] [Related]
17. Experimental determination of field factors ([Formula: see text]) for small radiotherapy beams using the daisy chain correction method. Lárraga-Gutiérrez JM Phys Med Biol; 2015 Aug; 60(15):5813-31. PubMed ID: 26161448 [TBL] [Abstract][Full Text] [Related]
18. Multi-site evaluation of the Razor stereotactic diode for CyberKnife small field relative dosimetry. Russo S; Masi L; Francescon P; Dicarolo P; De Martin E; Frassanito C; Redaelli I; Vigorito S; Stasi M; Mancosu P Phys Med; 2019 Sep; 65():40-45. PubMed ID: 31430585 [TBL] [Abstract][Full Text] [Related]
19. Determination of small field synthetic single-crystal diamond detector correction factors for CyberKnife, Leksell Gamma Knife Perfexion and linear accelerator. Veselsky T; Novotny J; Pastykova V; Koniarova I Phys Med; 2017 Dec; 44():66-71. PubMed ID: 29254593 [TBL] [Abstract][Full Text] [Related]
20. Output factor comparison of Monte Carlo and measurement for Varian TrueBeam 6 MV and 10 MV flattening filter-free stereotactic radiosurgery system. Cheng JY; Ning H; Arora BC; Zhuge Y; Miller RW J Appl Clin Med Phys; 2016 May; 17(3):100-110. PubMed ID: 27167266 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]