344 related articles for article (PubMed ID: 22842678)

  • 1. Monte Carlo modelling of diode detectors for small field MV photon dosimetry: detector model simplification and the sensitivity of correction factors to source parameterization.
    Cranmer-Sargison G; Weston S; Evans JA; Sidhu NP; Thwaites DI
    Phys Med Biol; 2012 Aug; 57(16):5141-53. PubMed ID: 22842678
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Design and experimental testing of air slab caps which convert commercial electron diodes into dual purpose, correction-free diodes for small field dosimetry.
    Charles PH; Cranmer-Sargison G; Thwaites DI; Kairn T; Crowe SB; Pedrazzini G; Aland T; Kenny J; Langton CM; Trapp JV
    Med Phys; 2014 Oct; 41(10):101701. PubMed ID: 25281940
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors.
    Cranmer-Sargison G; Weston S; Evans JA; Sidhu NP; Thwaites DI
    Med Phys; 2011 Dec; 38(12):6592-602. PubMed ID: 22149841
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method.
    Moignier C; Huet C; Makovicka L
    Med Phys; 2014 Jul; 41(7):071702. PubMed ID: 24989371
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Experimental small field 6 MV output ratio analysis for various diode detector and accelerator combinations.
    Cranmer-Sargison G; Weston S; Sidhu NP; Thwaites DI
    Radiother Oncol; 2011 Sep; 100(3):429-35. PubMed ID: 21945858
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dosimetry of cone-defined stereotactic radiosurgery fields with a commercial synthetic diamond detector.
    Morales JE; Crowe SB; Hill R; Freeman N; Trapp JV
    Med Phys; 2014 Nov; 41(11):111702. PubMed ID: 25370616
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Small field detector correction factors kQclin,Qmsr (fclin,fmsr) for silicon-diode and diamond detectors with circular 6 MV fields derived using both empirical and numerical methods.
    O'Brien DJ; León-Vintró L; McClean B
    Med Phys; 2016 Jan; 43(1):411. PubMed ID: 26745934
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monte Carlo calculated correction factors for diodes and ion chambers in small photon fields.
    Czarnecki D; Zink K
    Phys Med Biol; 2013 Apr; 58(8):2431-44. PubMed ID: 23514734
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Output correction factors for nine small field detectors in 6 MV radiation therapy photon beams: a PENELOPE Monte Carlo study.
    Benmakhlouf H; Sempau J; Andreo P
    Med Phys; 2014 Apr; 41(4):041711. PubMed ID: 24694131
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Spectral distribution of particle fluence in small field detectors and its implication on small field dosimetry.
    Benmakhlouf H; Andreo P
    Med Phys; 2017 Feb; 44(2):713-724. PubMed ID: 28032369
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monte Carlo-based diode design for correction-less small field dosimetry.
    Charles PH; Crowe SB; Kairn T; Knight RT; Hill B; Kenny J; Langton CM; Trapp JV
    Phys Med Biol; 2013 Jul; 58(13):4501-12. PubMed ID: 23760107
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 6-MV small field output factors: intra-/intermachine comparison and implementation of TRS-483 using various detectors and several linear accelerators.
    Ghazal M; Westermark M; Kaveckyte V; Carlsson-Tedgren Å; Benmakhlouf H
    Med Phys; 2019 Nov; 46(11):5350-5359. PubMed ID: 31532831
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correction factor measurements for multiple detectors used in small field dosimetry on the Varian Edge radiosurgery system.
    Tanny S; Sperling N; Parsai EI
    Med Phys; 2015 Sep; 42(9):5370-6. PubMed ID: 26328986
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monte Carlo calculated correction factors for the PTW microDiamond detector in the Gamma Knife-Model C.
    Barrett JC; Knill C
    Med Phys; 2016 Mar; 43(3):1035-44. PubMed ID: 26936691
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Non-reference condition correction factor kNR of typical radiation detectors applied for the dosimetry of high-energy photon fields in radiotherapy.
    Chofor N; Harder D; Poppe B
    Z Med Phys; 2012 Sep; 22(3):181-96. PubMed ID: 22658451
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Field correction factors for a PTW-31016 Pinpoint ionization chamber for both flattened and unflattened beams. Study of the main sources of uncertainties.
    Puxeu-Vaqué J; Duch MA; Nailon WH; Cruz Lizuain M; Ginjaume M
    Med Phys; 2017 May; 44(5):1930-1938. PubMed ID: 28261817
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental determination of field factors ([Formula: see text]) for small radiotherapy beams using the daisy chain correction method.
    Lárraga-Gutiérrez JM
    Phys Med Biol; 2015 Aug; 60(15):5813-31. PubMed ID: 26161448
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multi-site evaluation of the Razor stereotactic diode for CyberKnife small field relative dosimetry.
    Russo S; Masi L; Francescon P; Dicarolo P; De Martin E; Frassanito C; Redaelli I; Vigorito S; Stasi M; Mancosu P
    Phys Med; 2019 Sep; 65():40-45. PubMed ID: 31430585
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of small field synthetic single-crystal diamond detector correction factors for CyberKnife, Leksell Gamma Knife Perfexion and linear accelerator.
    Veselsky T; Novotny J; Pastykova V; Koniarova I
    Phys Med; 2017 Dec; 44():66-71. PubMed ID: 29254593
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Output factor comparison of Monte Carlo and measurement for Varian TrueBeam 6 MV and 10 MV flattening filter-free stereotactic radiosurgery system.
    Cheng JY; Ning H; Arora BC; Zhuge Y; Miller RW
    J Appl Clin Med Phys; 2016 May; 17(3):100-110. PubMed ID: 27167266
    [TBL] [Abstract][Full Text] [Related]  