BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

232 related articles for article (PubMed ID: 22843132)

  • 1. Comparison of superior-level facet joint violations during open and percutaneous pedicle screw placement.
    Babu R; Park JG; Mehta AI; Shan T; Grossi PM; Brown CR; Richardson WJ; Isaacs RE; Bagley CA; Kuchibhatla M; Gottfried ON
    Neurosurgery; 2012 Nov; 71(5):962-70. PubMed ID: 22843132
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Technical factors related to the incidence of adjacent superior segment facet joint violation after transpedicular instrumentation in the lumbar spine.
    Chen Z; Zhao J; Xu H; Liu A; Yuan J; Wang C
    Eur Spine J; 2008 Nov; 17(11):1476-80. PubMed ID: 18795343
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of cranial facet joint violation rates between open and percutaneous pedicle screw placement using intraoperative 3-D CT (O-arm) computer navigation.
    Yson SC; Sembrano JN; Sanders PC; Santos ER; Ledonio CG; Polly DW
    Spine (Phila Pa 1976); 2013 Feb; 38(4):E251-8. PubMed ID: 23197012
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Computed tomography evaluation of superior-segment facet-joint violation after pedicle instrumentation of the lumbar spine with a midline surgical approach.
    Moshirfar A; Jenis LG; Spector LR; Burke PJ; Losina E; Katz JN; Rand FF; Tromanhauser SG; Banco RJ
    Spine (Phila Pa 1976); 2006 Oct; 31(22):2624-9. PubMed ID: 17047555
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of Superior-Level Facet Joint Violations Between Robot-Assisted Percutaneous Pedicle Screw Placement and Conventional Open Fluoroscopic-Guided Pedicle Screw Placement.
    Zhang Q; Xu YF; Tian W; Le XF; Liu B; Liu YJ; He D; Sun YQ; Yuan Q; Lang Z; Han XG
    Orthop Surg; 2019 Oct; 11(5):850-856. PubMed ID: 31663290
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Anatomical and technical factors associated with superior facet joint violation in lumbar fusion.
    Teles AR; Paci M; Gutman G; Abduljabbar FH; Ouellet JA; Weber MH; Golan JD
    J Neurosurg Spine; 2018 Feb; 28(2):173-180. PubMed ID: 29219780
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analysis of risk factors for adjacent superior vertebral pedicle-induced facet joint violation during the minimally invasive surgery transforaminal lumbar interbody fusion: a retrospective study.
    Zeng ZL; Jia L; Xu W; Yu Y; Hu X; Jia YW; Wang JJ; Cheng LM
    Eur J Med Res; 2015 Sep; 20():80. PubMed ID: 26399320
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Incidence of and risk factors for superior facet violation in minimally invasive versus open pedicle screw placement during transforaminal lumbar interbody fusion: a comparative analysis.
    Lau D; Terman SW; Patel R; La Marca F; Park P
    J Neurosurg Spine; 2013 Apr; 18(4):356-61. PubMed ID: 23394166
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Lumbar spine superior-level facet joint violations: percutaneous versus open pedicle screw insertion using intraoperative 3-dimensional computer-assisted navigation.
    Tian W; Xu Y; Liu B; Liu Y; He D; Yuan Q; Lang Z; Lyu Y; Han X; Jin P
    Chin Med J (Engl); 2014; 127(22):3852-6. PubMed ID: 25421179
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Superior articulating facet violation: percutaneous versus open techniques.
    Jones-Quaidoo SM; Djurasovic M; Owens RK; Carreon LY
    J Neurosurg Spine; 2013 Jun; 18(6):593-7. PubMed ID: 23600584
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Risk Factors Related to Superior Facet Joint Violation During Lumbar Percutaneous Pedicle Screw Placement in Minimally Invasive Transforaminal Lumbar Interbody Fusion (MIS-TLIF).
    Zhao Y; Yuan S; Tian Y; Liu X
    World Neurosurg; 2020 Jul; 139():e716-e723. PubMed ID: 32360675
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Retrospective computed tomography scan analysis of percutaneously inserted pedicle screws for posterior transpedicular stabilization of the thoracic and lumbar spine: accuracy and complication rates.
    Raley DA; Mobbs RJ
    Spine (Phila Pa 1976); 2012 May; 37(12):1092-100. PubMed ID: 22037528
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cranial facet joint injuries in percutaneous lumbar pedicle screw placement: a matched-pair analysis comparing intraoperative 3D navigation and conventional fluoroscopy.
    Hohenhaus M; Watzlawick R; Masalha W; Volz F; Scholz C; Hubbe U; Klingler JH
    Eur Spine J; 2021 Jan; 30(1):88-96. PubMed ID: 32462309
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Facet Joint Violation During Percutaneous Pedicle Screw Placement: A Comparison of Two Techniques.
    Tannous O; Jazini E; Weir TB; Banagan KE; Koh EY; Greg Anderson D; Gelb DE; Ludwig SC
    Spine (Phila Pa 1976); 2017 Aug; 42(15):1189-1194. PubMed ID: 27922578
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Incidence and risk factors associated with superior-segmented facet joint violation during minimal invasive lumbar interbody fusion.
    Singhatanadgige W; Jaruprat P; Kerr SJ; Yingsakmongkol W; Kotheeranurak V; Limthongkul W
    Spine J; 2022 Sep; 22(9):1504-1512. PubMed ID: 35447323
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Radiologic evaluation of adjacent superior segment facet joint violation following transpedicular instrumentation of the lumbar spine.
    Shah RR; Mohammed S; Saifuddin A; Taylor BA
    Spine (Phila Pa 1976); 2003 Feb; 28(3):272-5. PubMed ID: 12567030
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Facet joint violation after open and percutaneous posterior instrumentation: a comparative study.
    Mitterer M; Ortmaier R; Wiesner T; Hitzl W; Mayer M
    Eur Spine J; 2023 Mar; 32(3):867-873. PubMed ID: 36633691
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Rates of Upper Facet Joint Violation in Minimally Invasive Percutaneous and Open Instrumentation: A Comparative Cohort Study of Different Insertion Techniques.
    Archavlis E; Amr N; Kantelhardt SR; Giese A
    J Neurol Surg A Cent Eur Neurosurg; 2018 Jan; 79(1):1-8. PubMed ID: 28672411
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cranial facet joint violations by percutaneously placed pedicle screws adjacent to a minimally invasive lumbar spinal fusion.
    Park Y; Ha JW; Lee YT; Sung NY
    Spine J; 2011 Apr; 11(4):295-302. PubMed ID: 21474080
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The biomechanical effect of pedicle screws' insertion angle and position on the superior adjacent segment in 1 segment lumbar fusion.
    Kim HJ; Chun HJ; Kang KT; Moon SH; Kim HS; Park JO; Moon ES; Kim BR; Sohn JS; Ko YN; Lee HM
    Spine (Phila Pa 1976); 2012 Sep; 37(19):1637-44. PubMed ID: 22089393
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.