232 related articles for article (PubMed ID: 22843132)
41. PLIF with a titanium cage and excised facet joint bone for degenerative spondylolisthesis--in augmentation with a pedicle screw.
Okuyama K; Kido T; Unoki E; Chiba M
J Spinal Disord Tech; 2007 Feb; 20(1):53-9. PubMed ID: 17285053
[TBL] [Abstract][Full Text] [Related]
42. A CT-Based Simulation Study to Compare the Risk of Facet Joint Violation by the Cervical Pedicle Screw Between Degenerative and Nondegenerative Cervical Spines.
Lee DH; Noh H; Hwang CJ; Lee CS; Abumi K; Cho JH
Spine (Phila Pa 1976); 2017 Feb; 42(3):E136-E141. PubMed ID: 28121962
[TBL] [Abstract][Full Text] [Related]
43. Risk Factor Analysis of Facet Fusion Following Cervical Lateral Mass Screw Fixation with a Minimum 1-Year Follow-up: Assessment of Maximal Insertional Screw Torque and Incidence of Loosening.
Kanematsu R; Hanakita J; Takahashi T; Minami M; Inoue T; Honda F
Neurol Med Chir (Tokyo); 2021 Jan; 61(1):40-46. PubMed ID: 33208584
[TBL] [Abstract][Full Text] [Related]
44. Percutaneous pedicle screw placements: accuracy and rates of cranial facet joint violation using conventional fluoroscopy compared with intraoperative three-dimensional computed tomography computer navigation.
Ohba T; Ebata S; Fujita K; Sato H; Haro H
Eur Spine J; 2016 Jun; 25(6):1775-80. PubMed ID: 26957097
[TBL] [Abstract][Full Text] [Related]
45. The combined use of unilateral pedicle screw and contralateral facet joint screw fixation in transforaminal lumbar interbody fusion.
Cao Y; Chen Z; Jiang C; Wan S; Jiang X; Feng Z
Eur Spine J; 2015 Nov; 24(11):2607-13. PubMed ID: 26174232
[TBL] [Abstract][Full Text] [Related]
46. Transforaminal lumbar interbody fusion: the effect of various instrumentation techniques on the flexibility of the lumbar spine.
Harris BM; Hilibrand AS; Savas PE; Pellegrino A; Vaccaro AR; Siegler S; Albert TJ
Spine (Phila Pa 1976); 2004 Feb; 29(4):E65-70. PubMed ID: 15094547
[TBL] [Abstract][Full Text] [Related]
47. Incidence and Risk Factors of Superior Facet Joint Violation in Percutaneous and Open Instrumentation Using Cortical Bone Trajectory Technique: A Comparison of Different Techniques.
Le X; Shi Z; Xu Y; Wang Q; Zhao J; Tian W
Clin Spine Surg; 2020 Apr; 33(3):E127-E134. PubMed ID: 31851014
[TBL] [Abstract][Full Text] [Related]
48. Radiographic fusion rate after implantation of facet bone dowels.
Pirris SM; Nottmeier EW; Rahmathulla G; Deen HG; Reimer R; Wharen RE
Spine J; 2014 Sep; 14(9):2102-11. PubMed ID: 24448193
[TBL] [Abstract][Full Text] [Related]
49. Superior Facet Joint Violations in Single Level Minimally Invasive and Open Transforaminal Lumbar Interbody Fusion: A Comparative Study.
Patel JY; Kundnani VG; Merchant ZI; Jain S; Kire N
Asian Spine J; 2020 Feb; 14(1):25-32. PubMed ID: 31575108
[TBL] [Abstract][Full Text] [Related]
50. Comparison of cranial facet joint violation rate between percutaneous and open pedicle screw placement: a systematic review and meta-analysis.
Wang L; Wang Y; Yu B; Li Z; Li Y
Medicine (Baltimore); 2015 Feb; 94(5):e504. PubMed ID: 25654397
[TBL] [Abstract][Full Text] [Related]
51. Adjacent segment degeneration after lumbar interbody fusion with percutaneous pedicle screw fixation for adult low-grade isthmic spondylolisthesis: minimum 3 years of follow-up.
Bae JS; Lee SH; Kim JS; Jung B; Choi G
Neurosurgery; 2010 Dec; 67(6):1600-7; discussion 1607-8. PubMed ID: 21107190
[TBL] [Abstract][Full Text] [Related]
52. [Facet Fixation Combined with Lumbar Interbody Fusion: Comparative Analysis of Clinical Experience and A New Method of Surgical Treatment of Patients with Lumbar Degenerative Diseases].
Byvaltsev VA; Kalinin AA; Okoneshnikova AK; Kerimbaev TT; Belykh EG
Vestn Ross Akad Med Nauk; 2016; 71(5):375-84. PubMed ID: 29297667
[TBL] [Abstract][Full Text] [Related]
53. [Comparison of accuracy between robot-assisted and fluoroscopy-guided percutaneous pedicle screw placement for treatment of lumbar spondylolisthesis].
Yang J; Hao D; Liu T; Liu P; He B; Xu X; Tuo Y; Zhang X; Li H
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2018 Nov; 32(11):1371-1376. PubMed ID: 30417609
[TBL] [Abstract][Full Text] [Related]
54. Rates and risk factors of intrapedicular accuracy and cranial facet joint violation among robot-assisted, fluoroscopy-guided percutaneous, and freehand techniques in pedicle screw fixation of thoracolumbar fractures: a comparative cohort study.
Zhang RJ; Zhou LP; Zhang HQ; Ge P; Jia CY; Shen CL
BMC Surg; 2022 Feb; 22(1):52. PubMed ID: 35148749
[TBL] [Abstract][Full Text] [Related]
55. Image-guided spine surgery: a cadaver study comparing conventional open laminoforaminotomy and two image-guided techniques for pedicle screw placement in posterolateral fusion and nonfusion models.
Austin MS; Vaccaro AR; Brislin B; Nachwalter R; Hilibrand AS; Albert TJ
Spine (Phila Pa 1976); 2002 Nov; 27(22):2503-8. PubMed ID: 12435982
[TBL] [Abstract][Full Text] [Related]
56. Safety evaluation of freehand lateral mass screw fixation in the subaxial cervical spine: evaluation of 1256 screws.
Kim HS; Suk KS; Moon SH; Lee HM; Kang KC; Lee SH; Kim JS
Spine (Phila Pa 1976); 2015 Jan; 40(1):2-5. PubMed ID: 25526587
[TBL] [Abstract][Full Text] [Related]
57. Incidence of lumbar spine pedicle breach after percutaneous screw fixation: a radiographic evaluation of 601 screws in 151 patients.
Smith ZA; Sugimoto K; Lawton CD; Fessler RG
J Spinal Disord Tech; 2014 Oct; 27(7):358-63. PubMed ID: 22688617
[TBL] [Abstract][Full Text] [Related]
58. The Rates and Risk Factors of Intra-Pedicular Accuracy and Proximal Facet Joint Violation for Single-Level Degenerative Lumbar Diseases: Cortical Bone Trajectory Versus Traditional Trajectory Pedicle Screw.
Zhang RJ; Zhou LP; Zhang L; Zhang HQ; Ge P; Jia CY; Zhang Y; Zhang JX; Shen CL
Spine (Phila Pa 1976); 2021 Dec; 46(23):E1274-E1282. PubMed ID: 33907083
[TBL] [Abstract][Full Text] [Related]
59. Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study.
Yang JS; He B; Tian F; Liu TJ; Liu P; Zhang JN; Liu SC; Tuo Y; Chu L; Hao DJ
Med Sci Monit; 2019 Apr; 25():2479-2487. PubMed ID: 30946733
[TBL] [Abstract][Full Text] [Related]
60. Superior-segment Bilateral Facet Violation in Lumbar Transpedicular Fixation, Part III: A Biomechanical Study of Severe Violation.
Xu Y; Le X; Zhang Q; Kuai S; Leng H; Duan F; Shi Z; Liu B; He D; Lang Z; Wu J; Wang L; Tian W
Spine (Phila Pa 1976); 2020 May; 45(9):E508-E514. PubMed ID: 31770344
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]