These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

48 related articles for article (PubMed ID: 22850081)

  • 1. A two-dimensional liquid-filled ionization chamber array prototype for small-field verification: characterization and first clinical tests.
    Brualla-González L; Gómez F; Vicedo A; González-Castaño DM; Gago-Arias A; Pazos A; Zapata M; Roselló JV; Pardo-Montero J
    Phys Med Biol; 2012 Aug; 57(16):5221-34. PubMed ID: 22850081
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development and clinical characterization of a novel 2041 liquid-filled ionization chambers array for high-resolution verification of radiotherapy treatments.
    Brualla-González L; Vázquez-Luque A; Zapata M; González-Castaño DM; Luna-Vega V; Guiu-Souto J; Prieto-Pena J; García T; Granero D; Vicedo A; Rosellò J; Pombar M; Gómez F; Pardo-Montero J
    Med Phys; 2018 Apr; 45(4):1771-1781. PubMed ID: 29446083
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development and operation of a pixel segmented liquid-filled linear array for radiotherapy quality assurance.
    Pardo J; Franco L; Gómez F; Iglesias A; Pazos A; Pena J; Lobato R; Mosquera J; Pombar M; Sendón J
    Phys Med Biol; 2005 Apr; 50(8):1703-16. PubMed ID: 15815091
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization of a two-dimensional liquid-filled ion chamber detector array used for verification of the treatments in radiotherapy.
    Markovic M; Stathakis S; Mavroidis P; Jurkovic IA; Papanikolaou N
    Med Phys; 2014 May; 41(5):051704. PubMed ID: 24784370
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Verification of intensity modulated profiles using a pixel segmented liquid-filled linear array.
    Pardo J; Roselló JV; Sánchez-Doblado F; Gómez F
    Phys Med Biol; 2006 Jun; 51(11):N211-9. PubMed ID: 16723758
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A liquid-filled ionization chamber for high precision relative dosimetry.
    González-Castaño DM; Gómez F; Brualla L; Roselló JV; Planes D; Sánchez M; Pombar M
    Phys Med; 2011 Apr; 27(2):89-96. PubMed ID: 20554236
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance parameters of a liquid filled ionization chamber array.
    Poppe B; Stelljes TS; Looe HK; Chofor N; Harder D; Willborn K
    Med Phys; 2013 Aug; 40(8):082106. PubMed ID: 23927343
    [TBL] [Abstract][Full Text] [Related]  

  • 8. D-IMRT verification with a 2D pixel ionization chamber: dosimetric and clinical results in head and neck cancer.
    Stasi M; Giordanengo S; Cirio R; Boriano A; Bourhaleb F; Cornelius I; Donetti M; Garelli E; Gomola I; Marchetto F; Porzio M; Sanz Freire CJ; Sardo A; Peroni C
    Phys Med Biol; 2005 Oct; 50(19):4681-94. PubMed ID: 16177497
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Characterization of a novel two dimensional diode array the "magic plate" as a radiation detector for radiation therapy treatment.
    Wong JH; Fuduli I; Carolan M; Petasecca M; Lerch ML; Perevertaylo VL; Metcalfe P; Rosenfeld AB
    Med Phys; 2012 May; 39(5):2544-58. PubMed ID: 22559625
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A 2D silicon detector array for quality assurance in small field dosimetry: DUO.
    Shukaili KA; Petasecca M; Newall M; Espinoza A; Perevertaylo VL; Corde S; Lerch M; Rosenfeld AB
    Med Phys; 2017 Feb; 44(2):628-636. PubMed ID: 28152195
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of chamber response function influence on IMRT verification using 2D commercial detector arrays.
    Gago-Arias A; Brualla-González L; González-Castaño DM; Gómez F; García MS; Vega VL; Sueiro JM; Pardo-Montero J
    Phys Med Biol; 2012 Apr; 57(7):2005-20. PubMed ID: 22429989
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spatial resolution of 2D ionization chamber arrays for IMRT dose verification: single-detector size and sampling step width.
    Poppe B; Djouguela A; Blechschmidt A; Willborn K; Rühmann A; Harder D
    Phys Med Biol; 2007 May; 52(10):2921-35. PubMed ID: 17473360
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transit dosimetry in IMRT with an a-Si EPID in direct detection configuration.
    Sabet M; Rowshanfarzad P; Vial P; Menk FW; Greer PB
    Phys Med Biol; 2012 Aug; 57(15):N295-306. PubMed ID: 22801089
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Microionization chamber for reference dosimetry in IMRT verification: clinical implications on OAR dosimetric errors.
    Sánchez-Doblado F; Capote R; Leal A; Roselló JV; Lagares JI; Arráns R; Hartmann GH
    Phys Med Biol; 2005 Mar; 50(5):959-70. PubMed ID: 15798268
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An investigation of the accuracy of Monte Carlo portal dosimetry for verification of IMRT with extended fields.
    Cufflin RS; Spezi E; Millin AE; Lewis DG
    Phys Med Biol; 2010 Aug; 55(16):4589-600. PubMed ID: 20668335
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of a liquid ionization chamber for stereotactic radiotherapy dosimetry.
    Wagner A; Crop F; Lacornerie T; Vandevelde F; Reynaert N
    Phys Med Biol; 2013 Apr; 58(8):2445-59. PubMed ID: 23514761
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Characterization of a 2D ion chamber array for the verification of radiotherapy treatments.
    Spezi E; Angelini AL; Romani F; Ferri A
    Phys Med Biol; 2005 Jul; 50(14):3361-73. PubMed ID: 16177515
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A methodology for verification of radiotherapy dose calculation.
    Agazaryan N; Ullrich W; Lee SP; Solberg TD
    J Neurosurg; 2004 Nov; 101 Suppl 3():356-61. PubMed ID: 15537190
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hybrid plan verification for intensity-modulated radiation therapy (IMRT) using the 2D ionization chamber array I'mRT MatriXX--a feasibility study.
    Dobler B; Streck N; Klein E; Loeschel R; Haertl P; Koelbl O
    Phys Med Biol; 2010 Jan; 55(2):N39-55. PubMed ID: 20023326
    [TBL] [Abstract][Full Text] [Related]  

  • 20. "Edge-on" MOSkin detector for stereotactic beam measurement and verification.
    Jong WL; Ung NM; Vannyat A; Jamalludin Z; Rosenfeld A; Wong JH
    Phys Med; 2017 Jan; 33():127-135. PubMed ID: 28089106
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.