These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
24. Emerging technologies for rapid identification of bloodstream pathogens. Kothari A; Morgan M; Haake DA Clin Infect Dis; 2014 Jul; 59(2):272-8. PubMed ID: 24771332 [TBL] [Abstract][Full Text] [Related]
25. Comparison of PCR-Electrospray Ionization Mass Spectrometry with 16S rRNA PCR and Amplicon Sequencing for Detection of Bacteria in Excised Heart Valves. Peeters B; Herijgers P; Beuselinck K; Peetermans WE; Herregods MC; Desmet S; Lagrou K J Clin Microbiol; 2016 Nov; 54(11):2825-2831. PubMed ID: 27629895 [TBL] [Abstract][Full Text] [Related]
26. Combination of conventional blood cultures and the SeptiFast molecular test in patients with suspected sepsis for the identification of bloodstream pathogens. Burdino E; Ruggiero T; Allice T; Milia MG; Gregori G; Milano R; Cerutti F; De Rosa FG; Manno E; Caramello P; Di Perri G; Ghisetti V Diagn Microbiol Infect Dis; 2014 Jul; 79(3):287-92. PubMed ID: 24780891 [TBL] [Abstract][Full Text] [Related]
27. Performance of PCR-REBA assay for screening and identifying pathogens directly in whole blood of patients with suspected sepsis. Wang HY; Kim J; Kim S; Park SD; Kim HY; Choi HK; Uh Y; Lee H J Appl Microbiol; 2015 Nov; 119(5):1433-42. PubMed ID: 26299262 [TBL] [Abstract][Full Text] [Related]
28. PCR-electrospray ionization mass spectrometry for direct detection of pathogens and antimicrobial resistance from heart valves in patients with infective endocarditis. Brinkman CL; Vergidis P; Uhl JR; Pritt BS; Cockerill FR; Steckelberg JM; Baddour LM; Maleszewski JJ; Edwards WD; Sampath R; Patel R J Clin Microbiol; 2013 Jul; 51(7):2040-6. PubMed ID: 23596241 [TBL] [Abstract][Full Text] [Related]
29. Broad-spectrum biosensor capable of detecting and identifying diverse bacterial and Candida species in blood. Metzgar D; Frinder M; Lovari R; Toleno D; Massire C; Blyn LB; Ranken R; Carolan HE; Hall TA; Moore D; Hansen CJ; Sampath R; Ecker DJ J Clin Microbiol; 2013 Aug; 51(8):2670-8. PubMed ID: 23761152 [TBL] [Abstract][Full Text] [Related]
30. Improving the diagnosis of bloodstream infections: PCR coupled with mass spectrometry. Jordana-Lluch E; Giménez M; Quesada MD; Ausina V; Martró E Biomed Res Int; 2014; 2014():501214. PubMed ID: 24818144 [TBL] [Abstract][Full Text] [Related]
31. Rapid identification of bacterial pathogens in positive blood culture bottles by use of a broad-based PCR assay coupled with high-resolution melt analysis. Won H; Rothman R; Ramachandran P; Hsieh YH; Kecojevic A; Carroll KC; Aird D; Gaydos C; Yang S J Clin Microbiol; 2010 Sep; 48(9):3410-3. PubMed ID: 20631110 [TBL] [Abstract][Full Text] [Related]
32. Rapid identification of bacteria and yeasts from positive-blood-culture bottles by using a lysis-filtration method and matrix-assisted laser desorption ionization-time of flight mass spectrum analysis with the SARAMIS database. Fothergill A; Kasinathan V; Hyman J; Walsh J; Drake T; Wang YF J Clin Microbiol; 2013 Mar; 51(3):805-9. PubMed ID: 23254131 [TBL] [Abstract][Full Text] [Related]
33. Identification of microorganisms directly from blood culture bottles with polymicrobial growth: comparison of FilmArray and direct MALDI-TOF MS. Almuhayawi MS; Wong AYW; Kynning M; Lüthje P; Ullberg M; Özenci V APMIS; 2021 Apr; 129(4):178-185. PubMed ID: 33368673 [TBL] [Abstract][Full Text] [Related]
34. Detection and identification of Ehrlichia species in blood by use of PCR and electrospray ionization mass spectrometry. Eshoo MW; Crowder CD; Li H; Matthews HE; Meng S; Sefers SE; Sampath R; Stratton CW; Blyn LB; Ecker DJ; Tang YW J Clin Microbiol; 2010 Feb; 48(2):472-8. PubMed ID: 19955274 [TBL] [Abstract][Full Text] [Related]
35. Broad-Range Detection of Microorganisms Directly from Bronchoalveolar Lavage Specimens by PCR/Electrospray Ionization-Mass Spectrometry. Ullberg M; Lüthje P; Mölling P; Strålin K; Özenci V PLoS One; 2017; 12(1):e0170033. PubMed ID: 28085931 [TBL] [Abstract][Full Text] [Related]
36. Comparison of an Unlabeled Probe High-Resolution Melting Analysis Assay (HRMA) for Factor V Leiden 1691 G/A Mutation to a Fluorogenic 5' Nuclease PCR Hydrolysis Assay. Han H; Lewis S J Appl Lab Med; 2024 Jul; 9(4):816-819. PubMed ID: 38775465 [TBL] [Abstract][Full Text] [Related]
37. Substantial diagnostic impact of blood culture independent molecular methods in bloodstream infections: Superior performance of PCR/ESI-MS. Makristathis A; Harrison N; Ratzinger F; Kussmann M; Selitsch B; Forstner C; Hirschl AM; Burgmann H Sci Rep; 2018 Oct; 8(1):16024. PubMed ID: 30375435 [TBL] [Abstract][Full Text] [Related]
38. Development of a multiplex real-time PCR assay for the rapid diagnosis of neonatal late onset sepsis. van den Brand M; Peters RPH; Catsburg A; Rubenjan A; Broeke FJ; van den Dungen FAM; van Weissenbruch MM; van Furth AM; Kõressaar T; Remm M; Savelkoul PHM; Bos MP J Microbiol Methods; 2014 Nov; 106():8-15. PubMed ID: 25102109 [TBL] [Abstract][Full Text] [Related]
39. Rapid diagnosis of bloodstream infections in the critically ill: Evaluation of the broad-range PCR/ESI-MS technology. Tassinari M; Zannoli S; Farabegoli P; Pedna MF; Pierro A; Mastroianni A; Fontan R; Luongo L; Sarnataro G; Menegatti E; Caruso A; Sambri V PLoS One; 2018; 13(5):e0197436. PubMed ID: 29763469 [TBL] [Abstract][Full Text] [Related]
40. A rapid, highly sensitive and culture-free detection of pathogens from blood by positive enrichment. Vutukuru MR; Sharma DK; Ragavendar MS; Schmolke S; Huang Y; Gumbrecht W; Mitra N J Microbiol Methods; 2016 Dec; 131():105-109. PubMed ID: 27765617 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]