These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
202 related articles for article (PubMed ID: 22858327)
41. Evaluation of optimal length and insertion torque for miniscrews. Suzuki M; Deguchi T; Watanabe H; Seiryu M; Iikubo M; Sasano T; Fujiyama K; Takano-Yamamoto T Am J Orthod Dentofacial Orthop; 2013 Aug; 144(2):251-9. PubMed ID: 23910206 [TBL] [Abstract][Full Text] [Related]
42. Pullout performance of self-tapping medical screws. Wu Z; Nassar SA; Yang X J Biomech Eng; 2011 Nov; 133(11):111002. PubMed ID: 22168734 [TBL] [Abstract][Full Text] [Related]
43. Tapered orthodontic miniscrews induce bone-screw cohesion following immediate loading. Yano S; Motoyoshi M; Uemura M; Ono A; Shimizu N Eur J Orthod; 2006 Dec; 28(6):541-6. PubMed ID: 17142258 [TBL] [Abstract][Full Text] [Related]
44. Finite element analysis of miniscrew implants used for orthodontic anchorage. Liu TC; Chang CH; Wong TY; Liu JK Am J Orthod Dentofacial Orthop; 2012 Apr; 141(4):468-76. PubMed ID: 22464529 [TBL] [Abstract][Full Text] [Related]
45. [Microscopic comparison of the miniscrew's surface used in orthodontics: before and after use]. Sebbar M; Bourzgui F; Lazrak L; Aazzab B; El Quars F Rev Stomatol Chir Maxillofac; 2012 Nov; 113(5):365-9. PubMed ID: 22695247 [TBL] [Abstract][Full Text] [Related]
46. Horizontal pull-out strength of orthodontic infrazygomatic mini-implant: an in vitro study. Chen CM; Wu JH; Lu PC; Wang HC; Lee HE; Wang CH; Du JK Implant Dent; 2011 Apr; 20(2):139-45. PubMed ID: 21448023 [TBL] [Abstract][Full Text] [Related]
47. Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses. Hsu CC; Chao CK; Wang JL; Hou SM; Tsai YT; Lin J J Orthop Res; 2005 Jul; 23(4):788-94. PubMed ID: 16022991 [TBL] [Abstract][Full Text] [Related]
48. Evaluation of the Effect of Platelet-Released Growth Factor and Immediate Orthodontic Loading on the Removal Torque of Miniscrews. Bayani S; Masoomi F; Aghaabbasi S; Farsinejad A Int J Oral Maxillofac Implants; 2016; 31(2):471-7. PubMed ID: 27004294 [TBL] [Abstract][Full Text] [Related]
49. Effects of insertion angle and implant thread type on the fracture properties of orthodontic mini-implants during insertion. Cho IS; Kim TW; Ahn SJ; Yang IH; Baek SH Angle Orthod; 2013 Jul; 83(4):698-704. PubMed ID: 23216058 [TBL] [Abstract][Full Text] [Related]
50. Surface changes of anodic oxidized orthodontic titanium miniscrew. Choi SH; Cha JY; Joo UH; Hwang CJ Angle Orthod; 2012 May; 82(3):522-8. PubMed ID: 22011095 [TBL] [Abstract][Full Text] [Related]
51. A comparison of tapered and cylindrical miniscrew stability. Yoo SH; Park YC; Hwang CJ; Kim JY; Choi EH; Cha JY Eur J Orthod; 2014 Oct; 36(5):557-62. PubMed ID: 24355870 [TBL] [Abstract][Full Text] [Related]
52. Increasing bending strength and pullout strength in conical pedicle screws: biomechanical tests and finite element analyses. Chao CK; Hsu CC; Wang JL; Lin J J Spinal Disord Tech; 2008 Apr; 21(2):130-8. PubMed ID: 18391719 [TBL] [Abstract][Full Text] [Related]
53. Success rates of single-thread and double-thread orthodontic miniscrews in the maxillary arch. Merati M; Ghaffari H; Javid F; Ahrari F BMC Oral Health; 2024 Feb; 24(1):191. PubMed ID: 38317101 [TBL] [Abstract][Full Text] [Related]
54. In-vitro impact of insertion angle on primary stability of miniscrews. Araghbidikashani M; Golshah A; Nikkerdar N; Rezaei M Am J Orthod Dentofacial Orthop; 2016 Sep; 150(3):436-43. PubMed ID: 27585771 [TBL] [Abstract][Full Text] [Related]
55. Factors influencing the stability of miniscrews. A retrospective study on 300 miniscrews. Manni A; Cozzani M; Tamborrino F; De Rinaldis S; Menini A Eur J Orthod; 2011 Aug; 33(4):388-95. PubMed ID: 20926556 [TBL] [Abstract][Full Text] [Related]
56. An in vitro investigation of peak insertion torque values of six commercially available mini-implants. Whang CZ; Bister D; Sherriff M Eur J Orthod; 2011 Dec; 33(6):660-6. PubMed ID: 21186241 [TBL] [Abstract][Full Text] [Related]
57. Biomechanical evaluation of an orthodontic miniimplant used with revolving (translation and rotation) temporary anchorage device by finite element analysis and experimental testing. Lin YS; Yu JH; Chang YZ; Lin CL Implant Dent; 2013 Feb; 22(1):77-82. PubMed ID: 23303268 [TBL] [Abstract][Full Text] [Related]
58. Effects of microgrooves on the success rate and soft tissue adaptation of orthodontic miniscrews. Kim TW; Baek SH; Kim JW; Chang YI Angle Orthod; 2008 Nov; 78(6):1057-64. PubMed ID: 18947283 [TBL] [Abstract][Full Text] [Related]
59. The effect of pilot hole size on the insertion torque and pullout strength of self-tapping cortical bone screws in osteoporotic bone. Battula S; Schoenfeld AJ; Sahai V; Vrabec GA; Tank J; Njus GO J Trauma; 2008 Apr; 64(4):990-5. PubMed ID: 18404066 [TBL] [Abstract][Full Text] [Related]
60. Effect of mini-implant length and diameter on primary stability under loading with two force levels. Chatzigianni A; Keilig L; Reimann S; Eliades T; Bourauel C Eur J Orthod; 2011 Aug; 33(4):381-7. PubMed ID: 21062964 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]