253 related articles for article (PubMed ID: 22860303)
1. [Awake intubation using Pentax-airway scope combined with surface airway anesthesia in the cases of two obese patients with cervical spondylosis and the author himself].
Yoshimura S; Shimosato A; Imanami M; Hatanaka T; Yasunaga S
Masui; 2012 Jul; 61(7):738-41. PubMed ID: 22860303
[TBL] [Abstract][Full Text] [Related]
2. [Use of the Airway Scope for awake intubation in five cases].
Taguchi A; Arai T; Enomoto Y; Chiba A; Kamishima K; Kuno Y; Okuda Y
Masui; 2010 Feb; 59(2):268-72. PubMed ID: 20169976
[TBL] [Abstract][Full Text] [Related]
3. [Awake intubation using Pentax Airway Scope as an alternative to awake fiberoptic intubation in management of anticipated difficult tracheal intubation in major burn patients].
Fayolle-Pivot L; Magnin C; Tissot S; Bertin-Maghit M; Allaouchiche B
Ann Fr Anesth Reanim; 2013 May; 32(5):355-7. PubMed ID: 23453928
[TBL] [Abstract][Full Text] [Related]
4. [A case of awake intubation using the Pentax-AWS airwayscope in a patient with a difficult airway combined with severe hemorrhagic shock].
Komasawa N; Shii H; Ueki R; Tatara T; Tashiro C; Kaminoh Y
Masui; 2013 Feb; 62(2):197-9. PubMed ID: 23479924
[TBL] [Abstract][Full Text] [Related]
5. Fibreoptic intubation in awake patients.
Andruszkiewicz P; Dec M; Kański A; Becler R
Anestezjol Intens Ter; 2010; 42(4):194-6. PubMed ID: 21252835
[TBL] [Abstract][Full Text] [Related]
6. Tracheal intubation by non-anesthesia residents using the Pentax-AWS airway scope and Macintosh laryngoscope.
Hirabayashi Y; Seo N
J Clin Anesth; 2009 Jun; 21(4):268-71. PubMed ID: 19502032
[TBL] [Abstract][Full Text] [Related]
7. Clinical assessment of awake endotracheal intubation using the lightwand technique alone in patients with difficult airways.
Xue FS; He N; Liao X; Xu XZ; Xu YC; Yang QY; Luo MP; Zhang YM
Chin Med J (Engl); 2009 Feb; 122(4):408-15. PubMed ID: 19302746
[TBL] [Abstract][Full Text] [Related]
8. Awake intubation with Airtraq laryngoscope in a morbidly obese patient.
Uakritdathikarn T; Asampinawat T; Wanasuwannakul T; Yoosamran B
J Med Assoc Thai; 2008 Apr; 91(4):564-7. PubMed ID: 18556868
[TBL] [Abstract][Full Text] [Related]
9. [Usability of AirWay Scope for awake tracheal intubation in a burn patient with difficult airway].
Kato T; Kusunoki S; Kawamoto M; Yuge O
Masui; 2007 Oct; 56(10):1179-81. PubMed ID: 17966622
[TBL] [Abstract][Full Text] [Related]
10. A randomised clinical trial comparing the flexible fibrescope and the Pentax Airway Scope (AWS)(®) for awake oral tracheal intubation.
Mendonca C; Mesbah A; Velayudhan A; Danha R
Anaesthesia; 2016 Aug; 71(8):908-14. PubMed ID: 27228959
[TBL] [Abstract][Full Text] [Related]
11. [Case of awake intubation in semi-sitting position for a patient with myasthenia gravis combined with cervical disc hernia utilizing Pentax-AWS Airwayscope].
Komasawa N; Ueki R; Tomita Y; Kaminoh Y; Tashiro C
Masui; 2011 Jan; 60(1):84-7. PubMed ID: 21348255
[TBL] [Abstract][Full Text] [Related]
12. The Murphy eye as guidance for topical airway anesthesia during awake tracheal intubation with a channeled blade videolaryngoscope.
Bruhn J; van Geffen GJ
J Clin Anesth; 2017 Nov; 42():53-54. PubMed ID: 28822318
[No Abstract] [Full Text] [Related]
13. [Pentax AWS airway scope].
Asai T; Enomoto Y; Shingu K; Okuda Y
Masui; 2007 Jul; 56(7):862-5. PubMed ID: 17633856
[TBL] [Abstract][Full Text] [Related]
14. [Successful awake tracheal intubation in the sitting position using the Pentax-AWS Airwayscope in a patient with hypopharyngeal cancer and gastroesophageal regurgitation].
Miyazaki Y; Komasawa N; Omoto H; Miyazaki S; Kido H; Minami T
Masui; 2014 Jun; 63(6):668-70. PubMed ID: 24979861
[TBL] [Abstract][Full Text] [Related]
15. Awake intubation with the Bonfils fibrescope in patients with difficult airway.
Corbanese U; Possamai C
Eur J Anaesthesiol; 2009 Oct; 26(10):837-41. PubMed ID: 19474737
[TBL] [Abstract][Full Text] [Related]
16. [Tracheal intubation with Pentax AWS Airway Scope after failed fiberoptic intubation and failed insertion of the intubating laryngeal mask airway].
Asai T; Ito I; Kuremoto Y; Kawashima A
Masui; 2010 Apr; 59(4):470-2. PubMed ID: 20420136
[TBL] [Abstract][Full Text] [Related]
17. [Successful nasal intubation using airway scope with gum elastic bougie in a case of difficult airway].
Inoue H; Saito T; Kamishima K; Okano T; Kuno Y; Arai T; Okuda Y
Masui; 2008 Apr; 57(4):457-9. PubMed ID: 18416204
[TBL] [Abstract][Full Text] [Related]
18. Fibre-optic awake intubation for caesarean section in a parturient with predicted difficult airway.
Trevisan P
Minerva Anestesiol; 2002 Oct; 68(10):775-81. PubMed ID: 12496724
[TBL] [Abstract][Full Text] [Related]
19. Awake orotracheal intubation under airway topical anesthesia using the Bonfils in patients with a predicted difficult airway.
He N; Xue FS; Xu YC; Liao X; Xu XZ
Can J Anaesth; 2008 Dec; 55(12):881-2. PubMed ID: 19050098
[No Abstract] [Full Text] [Related]
20. [Awake fiberoptic intubation - gold standard for the anticipated difficult airway].
Schenk A; Markus CK; Kranke P
Anasthesiol Intensivmed Notfallmed Schmerzther; 2014 Feb; 49(2):92-9. PubMed ID: 24563398
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]