BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 22863360)

  • 1. Improved neurologically intact survival with the use of an automated, load-distributing band chest compression device for cardiac arrest presenting to the emergency department.
    Hock Ong ME; Fook-Chong S; Annathurai A; Ang SH; Tiah L; Yong KL; Koh ZX; Yap S; Sultana P
    Crit Care; 2012 Aug; 16(4):R144. PubMed ID: 22863360
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of an automated, load-distributing band chest compression device for out-of-hospital cardiac arrest resuscitation.
    Ong ME; Ornato JP; Edwards DP; Dhindsa HS; Best AM; Ines CS; Hickey S; Clark B; Williams DC; Powell RG; Overton JL; Peberdy MA
    JAMA; 2006 Jun; 295(22):2629-37. PubMed ID: 16772626
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest: a randomized trial.
    Hallstrom A; Rea TD; Sayre MR; Christenson J; Anton AR; Mosesso VN; Van Ottingham L; Olsufka M; Pennington S; White LJ; Yahn S; Husar J; Morris MF; Cobb LA
    JAMA; 2006 Jun; 295(22):2620-8. PubMed ID: 16772625
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Load-distributing-band cardiopulmonary resuscitation for out-of-hospital cardiac arrest increases regional cerebral oxygenation: a single-center prospective pilot study.
    Ogawa Y; Shiozaki T; Hirose T; Ohnishi M; Nakamori Y; Ogura H; Shimazu T
    Scand J Trauma Resusc Emerg Med; 2015 Nov; 23():99. PubMed ID: 26568325
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Cardiopulmonary resuscitation interruptions with use of a load-distributing band device during emergency department cardiac arrest.
    Ong ME; Annathurai A; Shahidah A; Leong BS; Ong VY; Tiah L; Ang SH; Yong KL; Sultana P
    Ann Emerg Med; 2010 Sep; 56(3):233-41. PubMed ID: 20138401
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of mechanical chest compression device with a load-distributing band on post-resuscitation injuries identified by post-mortem computed tomography.
    Koga Y; Fujita M; Yagi T; Nakahara T; Miyauchi T; Kaneda K; Kawamura Y; Oda Y; Tsuruta R
    Resuscitation; 2015 Nov; 96():226-31. PubMed ID: 26335044
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanical versus manual chest compressions for cardiac arrest.
    Wang PL; Brooks SC
    Cochrane Database Syst Rev; 2018 Aug; 8(8):CD007260. PubMed ID: 30125048
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A randomized clinical trial of active compression-decompression CPR vs standard CPR in out-of-hospital cardiac arrest in two cities.
    Schwab TM; Callaham ML; Madsen CD; Utecht TA
    JAMA; 1995 Apr; 273(16):1261-8. PubMed ID: 7715038
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The impact of a new CPR assist device on rate of return of spontaneous circulation in out-of-hospital cardiac arrest.
    Casner M; Andersen D; Isaacs SM
    Prehosp Emerg Care; 2005; 9(1):61-7. PubMed ID: 16036830
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Managing cardiac arrest with refractory ventricular fibrillation in the emergency department: Conventional cardiopulmonary resuscitation versus extracorporeal cardiopulmonary resuscitation.
    Siao FY; Chiu CC; Chiu CW; Chen YC; Chen YL; Hsieh YK; Lee CH; Wu CT; Chou CC; Yen HH
    Resuscitation; 2015 Jul; 92():70-6. PubMed ID: 25936930
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Continuous chest compression versus interrupted chest compression for cardiopulmonary resuscitation of non-asphyxial out-of-hospital cardiac arrest.
    Zhan L; Yang LJ; Huang Y; He Q; Liu GJ
    Cochrane Database Syst Rev; 2017 Mar; 3(3):CD010134. PubMed ID: 28349529
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pre-shock chest compression pause effects on termination of ventricular fibrillation/tachycardia and return of organized rhythm within mechanical and manual cardiopulmonary resuscitation.
    Olsen JA; Brunborg C; Steinberg M; Persse D; Sterz F; Lozano M; Westfall M; Travis DT; Lerner EB; Brouwer MA; Wik L
    Resuscitation; 2015 Aug; 93():158-63. PubMed ID: 25933511
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mechanical chest compressions and simultaneous defibrillation vs conventional cardiopulmonary resuscitation in out-of-hospital cardiac arrest: the LINC randomized trial.
    Rubertsson S; Lindgren E; Smekal D; Östlund O; Silfverstolpe J; Lichtveld RA; Boomars R; Ahlstedt B; Skoog G; Kastberg R; Halliwell D; Box M; Herlitz J; Karlsten R
    JAMA; 2014 Jan; 311(1):53-61. PubMed ID: 24240611
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of active compression-decompression CPR in victims of out-of-hospital cardiac arrest.
    Lurie KG; Shultz JJ; Callaham ML; Schwab TM; Gisch T; Rector T; Frascone RJ; Long L
    JAMA; 1994 May; 271(18):1405-11. PubMed ID: 8176802
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Improving the quality of cardiopulmonary resuscitation by training dedicated cardiac arrest teams incorporating a mechanical load-distributing device at the emergency department.
    Ong ME; Quah JL; Annathurai A; Noor NM; Koh ZX; Tan KB; Pothiawala S; Poh AH; Loy CK; Fook-Chong S
    Resuscitation; 2013 Apr; 84(4):508-14. PubMed ID: 22906966
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Advanced life support performance with manual and mechanical chest compressions in a randomized, multicentre manikin study.
    Tomte O; Sunde K; Lorem T; Auestad B; Souders C; Jensen J; Wik L
    Resuscitation; 2009 Oct; 80(10):1152-7. PubMed ID: 19665833
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Outcomes of chest compression only CPR versus conventional CPR conducted by lay people in patients with out of hospital cardiopulmonary arrest witnessed by bystanders: nationwide population based observational study.
    Ogawa T; Akahane M; Koike S; Tanabe S; Mizoguchi T; Imamura T
    BMJ; 2011 Jan; 342():c7106. PubMed ID: 21273279
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical versus manual chest compressions for cardiac arrest.
    Brooks SC; Hassan N; Bigham BL; Morrison LJ
    Cochrane Database Syst Rev; 2014 Feb; (2):CD007260. PubMed ID: 24574099
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prehospital randomised assessment of a mechanical compression device in out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised trial and economic evaluation.
    Gates S; Lall R; Quinn T; Deakin CD; Cooke MW; Horton J; Lamb SE; Slowther AM; Woollard M; Carson A; Smyth M; Wilson K; Parcell G; Rosser A; Whitfield R; Williams A; Jones R; Pocock H; Brock N; Black JJ; Wright J; Han K; Shaw G; Blair L; Marti J; Hulme C; McCabe C; Nikolova S; Ferreira Z; Perkins GD
    Health Technol Assess; 2017 Mar; 21(11):1-176. PubMed ID: 28393757
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of manual and mechanical chest compression techniques using cerebral oximetry in witnessed cardiac arrests at the emergency department: A prospective, randomized clinical study.
    Baloglu Kaya F; Acar N; Ozakin E; Canakci ME; Kuas C; Bilgin M
    Am J Emerg Med; 2021 Mar; 41():163-169. PubMed ID: 33071075
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.