These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 22865424)

  • 1. Magnetic resonance assessment of left ventricular volumes and mass using a single-breath-hold 3D k-t BLAST cine b-SSFP in comparison with multiple-breath-hold 2D cine b-SSFP.
    Maffei E; Messalli G; Martini C; Rossi A; van Pelt N; van Geuns RJ; Weustink AC; Mollet NR; Nieman K; Aldrovandi A; Imbriaco M; Bogaert J; Cademartiri F
    Insights Imaging; 2011 Feb; 2(1):39-45. PubMed ID: 22865424
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Assessment of left ventricular volumes and mass with fast 3D cine steady-state free precession k-t space broad-use linear acquisition speed-up technique (k-t BLAST).
    Greil GF; Germann S; Kozerke S; Baltes C; Tsao J; Urschitz MS; Seeger A; Tangcharoen T; Bialkowsky A; Miller S; Sieverding L
    J Magn Reson Imaging; 2008 Mar; 27(3):510-5. PubMed ID: 18183581
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional magnetic resonance imaging using single breath-hold k-t BLAST for assessment of global left ventricular functional parameters.
    Jaroni J; Meier R; Beer A; Herrmann K; Settles M; Rummeny EJ; Huber A
    Acad Radiol; 2013 Aug; 20(8):987-94. PubMed ID: 23830604
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Left ventricular function assessment using a fast 3D gradient echo pulse sequence: comparison to standard multi-breath hold 2D steady state free precession imaging and accounting for papillary muscles and trabeculations.
    Sievers B; Schrader S; Rehwald W; Hunold P; Barkhausen J; Erbel R
    Acta Cardiol; 2011 Jun; 66(3):349-57. PubMed ID: 21744705
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of two single-breath-held 3-D acquisitions with multi-breath-held 2-D cine steady-state free precession MRI acquisition in children with single ventricles.
    Atweh LA; Dodd NA; Krishnamurthy R; Pednekar A; Chu ZD; Krishnamurthy R
    Pediatr Radiol; 2016 May; 46(5):637-45. PubMed ID: 26902296
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Feasibility of Three-Dimensional Balanced Steady-State Free Precession Cine Magnetic Resonance Imaging Combined with an Image Denoising Technique to Evaluate Cardiac Function in Children with Repaired Tetralogy of Fallot.
    Peng Y; Su X; Hu L; Wang Q; Ouyang R; Sun A; Guo C; Yao X; Zhang Y; Wang L; Zhong Y
    Korean J Radiol; 2021 Sep; 22(9):1525-1536. PubMed ID: 34448382
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fast 3D cine steady-state free precession imaging with sensitivity encoding for assessment of left ventricular function in a single breath-hold.
    Mascarenhas NB; Muthupillai R; Cheong B; Pereyra M; Flamm SD
    AJR Am J Roentgenol; 2006 Nov; 187(5):1235-9. PubMed ID: 17056910
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Single breath-hold assessment of cardiac function using an accelerated 3D single breath-hold acquisition technique--comparison of an intravascular and extravascular contrast agent.
    Makowski MR; Wiethoff AJ; Jansen CH; Uribe S; Parish V; Schuster A; Botnar RM; Bell A; Kiesewetter C; Razavi R; Schaeffter T; Greil GF
    J Cardiovasc Magn Reson; 2012 Jul; 14(1):53. PubMed ID: 22849703
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Free breathing 2D multi-slice real-time gradient-echo cardiovascular magnetic resonance imaging: impact on left ventricular function measurements compared with standard multi-breath hold 2D steady-state free precession imaging.
    Sievers B; Schrader S; Hunold P; Barkhausen J; Erbel R
    Acta Cardiol; 2011 Aug; 66(4):489-97. PubMed ID: 21894806
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reliability of pediatric ventricular function analysis by short-axis "single-cycle-stack-advance" single-shot compressed-sensing cines in minimal breath-hold time.
    Hatipoglu S; Gatehouse P; Krupickova S; Banya W; Daubeney P; Almogheer B; Izgi C; Weale P; Hayes C; Firmin D; Pennell DJ
    Eur Radiol; 2022 Apr; 32(4):2581-2593. PubMed ID: 34713331
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Single breath-hold assessment of ventricular volumes using 32-channel coil technology and an extracellular contrast agent.
    Parish V; Hussain T; Beerbaum P; Greil G; Nagel E; Razavi R; Schaeffter T; Uribe S
    J Magn Reson Imaging; 2010 Apr; 31(4):838-44. PubMed ID: 20373427
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of global cardiac functional parameters using single-breath-hold three-dimensional cine steady-state free precession MR imaging with two types of speed-up techniques: comparison with two-dimensional cine imaging.
    Amano Y; Suzuki Y; van Cauteren M
    Comput Med Imaging Graph; 2008 Jan; 32(1):61-6. PubMed ID: 17980553
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Compressed sensing cine imaging with high spatial or high temporal resolution for analysis of left ventricular function.
    Goebel J; Nensa F; Schemuth HP; Maderwald S; Gratz M; Quick HH; Schlosser T; Nassenstein K
    J Magn Reson Imaging; 2016 Aug; 44(2):366-74. PubMed ID: 26789014
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Single breath hold 3D cardiac cine MRI using kat-ARC: preliminary results at 1.5T.
    Jeong D; Schiebler ML; Lai P; Wang K; Vigen KK; François CJ
    Int J Cardiovasc Imaging; 2015 Apr; 31(4):851-7. PubMed ID: 25680356
    [TBL] [Abstract][Full Text] [Related]  

  • 15. MRI Assessment of Right Ventricular Volumes and Function in Patients With Repaired Tetralogy of Fallot Using kat-ARC Accelerated Sequences.
    Vial J; Bouzerar R; Pichois R; Lhostis F; Raad O; Mathiron A; Renard C
    AJR Am J Roentgenol; 2020 Oct; 215(4):807-817. PubMed ID: 32755352
    [No Abstract]   [Full Text] [Related]  

  • 16. Aortic annular dimensions by non-contrast MRI using k-t accelerated 3D cine b-SSFP in pre-procedural assessment for transcatheter aortic valve implantation: a technical feasibility study.
    Aouad P; Jarvis KB; Botelho MF; Serhal A; Blaisdell J; Collins L; Giri S; Kim D; Markl M; Ricciardi MJ; Davidson CJ; Collins J; Carr J
    Int J Cardiovasc Imaging; 2021 Feb; 37(2):651-661. PubMed ID: 32968888
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reliability of respiratory-triggered two-dimensional cine k-adaptive-t-autocalibrating reconstruction for Cartesian sampling for the assessment of biventricular volume and function in patients with repaired tetralogy of Fallot.
    Orii M; Sugawara T; Takagi H; Nakano S; Ueda H; Takizawa Y; Fujiwara J; Takahashi S; Oyama K; Lai P; Janich MA; Nozaki A; Yoshioka K
    Br J Radiol; 2021 Apr; 94(1120):20201249. PubMed ID: 33733811
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine.
    Nassenstein K; Eberle H; Maderwald S; Jensen CJ; Heilmaier C; Schlosser T; Bruder O
    Eur Radiol; 2010 Oct; 20(10):2341-7. PubMed ID: 20532781
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Feasibility of Single-Breath-Hold Compressed Sensing Real-Time Cine Imaging for Assessment of Ventricular Function and Left Ventricular Strain in Cardiac Magnetic Resonance].
    Deng Q; Tang L; Wu X; Wu T; He S; Li L; Cheng W; Diao YK; Diao KY; Yue WJ; Chen YC; Sun JY
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2022 May; 53(3):497-503. PubMed ID: 35642161
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of left ventricular function assessment using phonocardiogram- and electrocardiogram-triggered 2D SSFP CINE MR imaging at 1.5 T and 3.0 T.
    Becker M; Frauenrath T; Hezel F; Krombach GA; Kremer U; Koppers B; Butenweg C; Goemmel A; Utting JF; Schulz-Menger J; Niendorf T
    Eur Radiol; 2010 Jun; 20(6):1344-55. PubMed ID: 20013275
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.