These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 22872605)

  • 1. Diathermy-induced ventricular fibrillation with Riata high-voltage lead insulation failure.
    Gunaruwan P; Barlow M
    Europace; 2013 Apr; 15(4):473. PubMed ID: 22872605
    [No Abstract]   [Full Text] [Related]  

  • 2. Use of an automatic internal defibrillator to induce and maintain ventricular fibrillation during left ventricular assist device pump exchange.
    Levin MA; Anyanwu AC; Eggert CA; Mittnacht AJ
    J Thorac Cardiovasc Surg; 2014 Mar; 147(3):e17-8. PubMed ID: 24290714
    [No Abstract]   [Full Text] [Related]  

  • 3. Electrocautery-induced ventricular fibrillation during routine implantable cardioverter-defibrillator generator replacement.
    Cassagneau R; Hanninen M; Yee R
    Europace; 2014 Mar; 16(3):319. PubMed ID: 24068449
    [No Abstract]   [Full Text] [Related]  

  • 4. Prolonged sustained ventricular fibrillation in a patient with dextrocardia and a left ventricular assist device.
    Bolzan B; Morani G; Tomei R; Tomasi L; Borio G; Ribichini FL
    J Cardiovasc Med (Hagerstown); 2019 Oct; 20(10):721-724. PubMed ID: 31389822
    [No Abstract]   [Full Text] [Related]  

  • 5. Idiopathic ventricular fibrillation triggered by premature atrial complexes.
    Iizuka T; Kaneko Y; Nakajima T; Kurabayashi M
    J Cardiovasc Electrophysiol; 2015 Jan; 26(1):98-100. PubMed ID: 25216017
    [No Abstract]   [Full Text] [Related]  

  • 6. Possible late diagnosis of the Brugada syndrome in a patient presenting with a primary cardiac arrest.
    Moore PT; Kaye GC
    Europace; 2015 Dec; 17(12):1839. PubMed ID: 25911350
    [No Abstract]   [Full Text] [Related]  

  • 7. Conductor externalization in a Riata ST Optimâ„¢ lead.
    Deeprasertkul P; Yunus A; Thakur R
    Europace; 2013 Jul; 15(7):1012. PubMed ID: 23419661
    [No Abstract]   [Full Text] [Related]  

  • 8. Conductor externalization of the RIATA implantable cardioverter defibrillator lead: a challenging lead extraction requiring laser-powered sheath.
    Migliore F; Bertaglia E; Bontempi L; Verlato R; Leoni L; Iliceto S; Curnis A
    J Cardiovasc Med (Hagerstown); 2013 Oct; 14(10):755-6. PubMed ID: 23996009
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Post-shock oversensing by a subcutaneous defibrillator resulting in inappropriate withholding of post-shock bradycardia pacing.
    Maass AH; Van Gelder IC
    Europace; 2014 Jul; 16(7):1032. PubMed ID: 24792457
    [No Abstract]   [Full Text] [Related]  

  • 10. Twisting until it breaks: a rare cause of ICD lead failure.
    Budzikowski AS; Uyguanco E; Gunsburg MY; Kassotis J
    Cardiol J; 2008; 15(6):558-60. PubMed ID: 19039762
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Paradoxical thromboembolic stroke during extraction of a recalled St Jude Medical Riata defibrillator lead with conductor externalization.
    Larsen JM; Theuns DA; Thøgersen AM
    Europace; 2014 Feb; 16(2):240. PubMed ID: 23933851
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ventricular fibrillation undersensing due to air entrapment in a patient implanted with a subcutaneous cardioverter defibrillator.
    Adduci C; Spadoni L; Palano F; Francia P
    J Cardiovasc Electrophysiol; 2019 Aug; 30(8):1373-1374. PubMed ID: 31165543
    [No Abstract]   [Full Text] [Related]  

  • 13. Circadian variations in ST-segment elevation surrounding the spontaneous onset of ventricular fibrillation in Brugada syndrome.
    Kaneko Y; Nakajima T; Ota M; Kurabayashi M
    J Cardiovasc Electrophysiol; 2012 Jun; 23(6):664-5. PubMed ID: 22004590
    [No Abstract]   [Full Text] [Related]  

  • 14. Failure-free survival of the Durata defibrillator lead.
    Liu J; Patel D; Rattan R; Brumberg G; Saini A; Vaghasia N; Bazaz R; Adelstein E; Jain S; Saba S
    Europace; 2013 Jul; 15(7):1002-6. PubMed ID: 23376976
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A case of in vivo thrombogenicity of an externalized Riata ST lead.
    Ricciardi D; La Meir M; de Asmundis C; Brugada P
    Europace; 2013 Mar; 15(3):428. PubMed ID: 23430751
    [No Abstract]   [Full Text] [Related]  

  • 16. Developing a crush: acute implantable cardioverter-defibrillator lead insulation break in a patient with multiple leads.
    Tilling L; Mason M
    Europace; 2014 Aug; 16(8):1196. PubMed ID: 25074973
    [No Abstract]   [Full Text] [Related]  

  • 17. Seventh try's a charm: ventricular fibrillation terminated by the seventh shock.
    Li J; Zitron E; Katus HA; Becker R
    Circ Arrhythm Electrophysiol; 2011 Apr; 4(2):e4-6. PubMed ID: 21505170
    [No Abstract]   [Full Text] [Related]  

  • 18. Ventricular fibrillation triggered by a pacemaker-mediated tachycardia protection algorithm.
    Galand V; Behar N; Martins RP
    Europace; 2017 Aug; 19(8):1342. PubMed ID: 28444182
    [No Abstract]   [Full Text] [Related]  

  • 19. New approach to implantable cardioverter-defibrillators in small pediatric patients: dorsal positioning of superior vena cava shock lead in a 3-year-old.
    Pedersen SB; Smerup MH; Nielsen JC
    J Thorac Cardiovasc Surg; 2014 Jul; 148(1):358-60. PubMed ID: 24685380
    [No Abstract]   [Full Text] [Related]  

  • 20. Complete tear-off of a Riata dual coil lead tip.
    Erath JW; Monsefi N; Hohnloser SH
    Europace; 2017 Nov; 19(11):1902. PubMed ID: 27733461
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.