These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
127 related articles for article (PubMed ID: 22886569)
1. Can intermuscular cleavage planes provide proper transverse screw angle? Comparison of two paraspinal approaches. Cheng X; Ni B; Liu Q; Chen J; Guan H Eur Spine J; 2013 Jan; 22(1):123-7. PubMed ID: 22886569 [TBL] [Abstract][Full Text] [Related]
2. Multilevel magnetic resonance imaging analysis of multifidus-longissimus cleavage planes in the lumbar spine and potential clinical applications to Wiltse's paraspinal approach. Palmer DK; Allen JL; Williams PA; Voss AE; Jadhav V; Wu DS; Cheng WK Spine (Phila Pa 1976); 2011 Jul; 36(16):1263-7. PubMed ID: 21242875 [TBL] [Abstract][Full Text] [Related]
3. Comparison of Wiltse's paraspinal approach and open book laminectomy for thoracolumbar burst fractures with greenstick lamina fractures: a randomized controlled trial. Chen ZD; Wu J; Yao XT; Cai TY; Zeng WR; Lin B J Orthop Surg Res; 2018 Mar; 13(1):43. PubMed ID: 29499742 [TBL] [Abstract][Full Text] [Related]
4. Anatomic parameters: direct intralaminar screw repair of spondylolysis. Menga EN; Jain A; Kebaish KM; Zimmerman SL; Sponseller PD Spine (Phila Pa 1976); 2014 Feb; 39(3):E153-8. PubMed ID: 24253779 [TBL] [Abstract][Full Text] [Related]
5. Morphometric study of the lumbar pedicle in the Indian population as related to pedicular screw fixation. Mitra SR; Datir SP; Jadhav SO Spine (Phila Pa 1976); 2002 Mar; 27(5):453-9. PubMed ID: 11880829 [TBL] [Abstract][Full Text] [Related]
6. Does a deep seated L5 vertebra position with respect to the iliac crests affect the accuracy of percutaneous pedicle screw placement at lumbosacral junction? Guo J; Guo L; Gao J; Ling Q; Yin Z; He E BMC Musculoskelet Disord; 2017 May; 18(1):180. PubMed ID: 28476112 [TBL] [Abstract][Full Text] [Related]
7. An anatomical study of the mid-lateral pars relative to the pedicle footprint in the lower lumbar spine. Su BW; Kim PD; Cha TD; Lee J; April EW; Weidenbaum M; Vaccaro AR Spine (Phila Pa 1976); 2009 Jun; 34(13):1355-62. PubMed ID: 19478655 [TBL] [Abstract][Full Text] [Related]
8. [Study of pedicle screw placement assisted by intraoperative three-dimensional navigation in lumbar vertebrae with axial rotation]. Tian W; Lang Z; Liu YJ; Liu B; Li Q; Hu L; Li ZY; Yuan Q; He D; Cheng XG; Sun YZ Zhonghua Wai Ke Za Zhi; 2010 Jun; 48(11):838-41. PubMed ID: 21163053 [TBL] [Abstract][Full Text] [Related]
9. Advantages of the paraspinal muscle splitting approach in comparison with conventional midline approach for s1 pedicle screw placement. Ota M; Neo M; Fujibayashi S; Takemoto M; Nakamura T Spine (Phila Pa 1976); 2010 May; 35(11):E452-7. PubMed ID: 20473116 [TBL] [Abstract][Full Text] [Related]
10. Accuracy of pedicle screw placement in posterior lumbosacral instrumentation by computer tomography evaluation: A multi-centric retrospective clinical study. Yu T; Mi S; He Y; Zhang Z; Dai W; Tian J; Hong Z; Fan S; Zhao F Int J Surg; 2017 Jul; 43():46-51. PubMed ID: 28546099 [TBL] [Abstract][Full Text] [Related]
11. Morphometric Analysis of the Lumbar Vertebrae Concerning the Optimal Screw Selection for Transpedicular Stabilization. Dzierżanowski J; Skotarczyk M; Baczkowska-Waliszewska Z; Krakowiak M; Radkowski M; Łuczkiewicz P; Czapiewski P; Szmuda T; Słoniewski P; Szurowska E; Winklewski PJ; Demkow U; Szarmach A Adv Exp Med Biol; 2019; 1133():83-96. PubMed ID: 30680647 [TBL] [Abstract][Full Text] [Related]
12. In vivo dynamic motion characteristics of the lower lumbar spine: L4-5 lumbar degenerative disc diseases undergoing unilateral or bilateral pedicle screw fixation combined with TLIF. Nie T; Chen DJ; Tang B; Song Q; Liu X; Zhang B; Dai M; Li G; Wan Z J Orthop Surg Res; 2019 Jun; 14(1):171. PubMed ID: 31174560 [TBL] [Abstract][Full Text] [Related]
14. Transforaminal lumbar interbody fusion: the effect of various instrumentation techniques on the flexibility of the lumbar spine. Harris BM; Hilibrand AS; Savas PE; Pellegrino A; Vaccaro AR; Siegler S; Albert TJ Spine (Phila Pa 1976); 2004 Feb; 29(4):E65-70. PubMed ID: 15094547 [TBL] [Abstract][Full Text] [Related]
15. Three-dimensional image-guided placement of S2 alar screws to adjunct or salvage lumbosacral fixation. Nottmeier EW; Pirris SM; Balseiro S; Fenton D Spine J; 2010 Jul; 10(7):595-601. PubMed ID: 20434406 [TBL] [Abstract][Full Text] [Related]
16. Verification of the position of pedicle screws in lumbar spinal fusion. Haaker RG; Eickhoff U; Schopphoff E; Steffen R; Jergas M; Krämer J Eur Spine J; 1997; 6(2):125-8. PubMed ID: 9209881 [TBL] [Abstract][Full Text] [Related]
17. Morphometric measurement of the lumbosacral spine for minimally invasive cortical bone trajectory implant using computed tomography. Zhang H; Ajiboye RM; Shamie AN; Wu Q; Chen Q; Chen W Eur Spine J; 2016 Mar; 25(3):870-6. PubMed ID: 26342703 [TBL] [Abstract][Full Text] [Related]
18. Morphometric analysis using multiplanar reconstructed CT of the lumbar pedicle in patients with degenerative lumbar scoliosis characterized by a Cobb angle of 30° or greater. Makino T; Kaito T; Fujiwara H; Yonenobu K J Neurosurg Spine; 2012 Sep; 17(3):256-62. PubMed ID: 22794782 [TBL] [Abstract][Full Text] [Related]
19. Pedicle screw placement with a free hand technique in thoracolumbar spine: is it safe? Karapinar L; Erel N; Ozturk H; Altay T; Kaya A J Spinal Disord Tech; 2008 Feb; 21(1):63-7. PubMed ID: 18418139 [TBL] [Abstract][Full Text] [Related]
20. Anatomical considerations for cervical pedicle screw insertion: the use of multiplanar computerized tomography measurements in 122 consecutive clinical cases. Onibokun A; Khoo LT; Bistazzoni S; Chen NF; Sassi M Spine J; 2009 Sep; 9(9):729-34. PubMed ID: 19699462 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]