These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Performing elemental microanalysis with high accuracy and high precision by scanning electron microscopy/silicon drift detector energy-dispersive X-ray spectrometry (SEM/SDD-EDS). Newbury DE; Ritchie NW J Mater Sci; 2015; 50(2):493-518. PubMed ID: 26346887 [TBL] [Abstract][Full Text] [Related]
3. Quantitative Electron-Excited X-Ray Microanalysis of Borides, Carbides, Nitrides, Oxides, and Fluorides with Scanning Electron Microscopy/Silicon Drift Detector Energy-Dispersive Spectrometry (SEM/SDD-EDS) and NIST DTSA-II. Newbury DE; Ritchie NW Microsc Microanal; 2015 Oct; 21(5):1327-40. PubMed ID: 26365439 [TBL] [Abstract][Full Text] [Related]
4. Measurement of Trace Constituents by Electron-Excited X-Ray Microanalysis with Energy-Dispersive Spectrometry. Newbury DE; Ritchie NW Microsc Microanal; 2016 Jun; 22(3):520-35. PubMed ID: 27329308 [TBL] [Abstract][Full Text] [Related]
5. WDS versus silicon drift detector EDS: a case report for the comparison of quantitative chemical analyses of natural silicate minerals. Cubukçu HE; Ersoy O; Aydar E; Cakir U Micron; 2008; 39(2):88-94. PubMed ID: 17188880 [TBL] [Abstract][Full Text] [Related]
6. Overcoming Peak Overlaps in Titanium- and Vanadium-Bearing Materials with Multiple Linear Least Squares Fitting. Mengason M; Ritchie N Microsc Microanal; 2017 Jun; 23(3):491-500. PubMed ID: 28281410 [TBL] [Abstract][Full Text] [Related]
7. Mistakes encountered during automatic peak identification of minor and trace constituents in electron-excited energy dispersive X-ray microanalysis. Newbury DE Scanning; 2009; 31(3):91-101. PubMed ID: 19533682 [TBL] [Abstract][Full Text] [Related]
8. Electron-Excited X-ray Microanalysis by Energy Dispersive Spectrometry at 50: Analytical Accuracy, Precision, Trace Sensitivity, and Quantitative Compositional Mapping. Newbury DE; Ritchie NWM Microsc Microanal; 2019 Oct; 25(5):1075-1105. PubMed ID: 31439058 [TBL] [Abstract][Full Text] [Related]
9. EDS measurements of X-ray intensity at WDS precision and accuracy using a silicon drift detector. Ritchie NW; Newbury DE; Davis JM Microsc Microanal; 2012 Aug; 18(4):892-904. PubMed ID: 22846890 [TBL] [Abstract][Full Text] [Related]
10. New reference and test materials for the characterization of energy dispersive X-ray spectrometers at scanning electron microscopes. Rackwitz V; Krumrey M; Laubis C; Scholze F; Hodoroaba VD Anal Bioanal Chem; 2015 Apr; 407(11):3045-53. PubMed ID: 25326887 [TBL] [Abstract][Full Text] [Related]
11. Electron-excited energy dispersive X-ray spectrometry at high speed and at high resolution: silicon drift detectors and microcalorimeters. Newbury DE Microsc Microanal; 2006 Dec; 12(6):527-37. PubMed ID: 19830945 [TBL] [Abstract][Full Text] [Related]
12. The determination of the efficiency of energy dispersive X-ray spectrometers by a new reference material. Alvisi M; Blome M; Griepentrog M; Hodoroaba VD; Karduck P; Mostert M; Nacucchi M; Procop M; Rohde M; Scholze F; Statham P; Terborg R; Thiot JF Microsc Microanal; 2006 Oct; 12(5):406-15. PubMed ID: 16984667 [TBL] [Abstract][Full Text] [Related]
13. Celebrating 40 years of energy dispersive X-ray spectrometry in electron probe microanalysis: a historic and nostalgic look back into the beginnings. Keil K; Fitzgerald R; Heinrich KF Microsc Microanal; 2009 Dec; 15(6):476-83. PubMed ID: 19804655 [TBL] [Abstract][Full Text] [Related]
14. An Iterative Qualitative-Quantitative Sequential Analysis Strategy for Electron-Excited X-ray Microanalysis with Energy Dispersive Spectrometry: Finding the Unexpected Needles in the Peak Overlap Haystack. Newbury DE; Ritchie NWM Microsc Microanal; 2018 Aug; 24(4):350-373. PubMed ID: 30175703 [TBL] [Abstract][Full Text] [Related]
15. The new X-ray mapping: X-ray spectrum imaging above 100 kHz output count rate with the silicon drift detector. Newbury DE Microsc Microanal; 2006 Feb; 12(1):26-35. PubMed ID: 17481339 [TBL] [Abstract][Full Text] [Related]
16. Electron-Excited X-Ray Microanalysis at Low Beam Energy: Almost Always an Adventure! Newbury DE; Ritchie NW Microsc Microanal; 2016 Aug; 22(4):735-53. PubMed ID: 27515566 [TBL] [Abstract][Full Text] [Related]
17. Mistakes encountered during automatic peak identification in low beam energy X-ray microanalysis. Newbury DE Scanning; 2007; 29(4):137-51. PubMed ID: 17676629 [TBL] [Abstract][Full Text] [Related]
19. Barriers to Quantitative Electron Probe X-Ray Microanalysis for Low Voltage Scanning Electron Microscopy. Newbury DE J Res Natl Inst Stand Technol; 2002; 107(6):605-19. PubMed ID: 27446755 [TBL] [Abstract][Full Text] [Related]
20. The f-Ratio Quantification Method for X-ray Microanalysis Applied to Mg-Al-Zn Alloys. Teng C; Demers H; Chu X; Gauvin R Microsc Microanal; 2019 Feb; 25(1):58-69. PubMed ID: 30714545 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]