These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 22886972)

  • 1. A biomechanical comparison of conventional versus an anatomic plate and compression bolts for fixation of intra-articular calcaneal fractures.
    Wang H; Yang Z; Wu Z; Chen W; Zhang Q; Li M; Li Z; Zhang Y
    J Huazhong Univ Sci Technolog Med Sci; 2012 Aug; 32(4):571-575. PubMed ID: 22886972
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Functional outcome of displaced intra-articular calcaneal fractures: a comparison between open reduction/internal fixation and a minimally invasive approach featured an anatomical plate and compression bolts.
    Wu Z; Su Y; Chen W; Zhang Q; Liu Y; Li M; Wang H; Zhang Y
    J Trauma Acute Care Surg; 2012 Sep; 73(3):743-51. PubMed ID: 23007019
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comminuted intraarticular calcaneal fractures: Multiplanar VA locked plating and interlocked nailing incorporate longitudinal strut and provide superior stability - a biomechanical cadaveric study.
    Stefanov A; Ivanov S; Zderic I; Baltov A; Rashkov M; Gehweiler D; Richards G; Gueorguiev B; Enchev D
    Injury; 2022 Oct; 53(10):3543-3552. PubMed ID: 35810043
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical comparison of locking plate and crossing metallic and absorbable screws fixations for intra-articular calcaneal fractures.
    Ni M; Wong DW; Mei J; Niu W; Zhang M
    Sci China Life Sci; 2016 Sep; 59(9):958-64. PubMed ID: 27349998
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of conventional and anatomical calcaneal plates for the treatment of intraarticular calcaneal fractures - a finite element study.
    Yu B; Chen WC; Lee PY; Lin KP; Lin KJ; Tsai CL; Wei HW
    Comput Methods Biomech Biomed Engin; 2016 Oct; 19(13):1363-70. PubMed ID: 26813403
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Biomechanical comparison of three kinds of fixation instruments for calcaneal osteotomy].
    Bai J; Xu Y; He X; Li C; Liu S; Li L
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2018 Feb; 32(2):192-194. PubMed ID: 29806411
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparative biomechanical study for complex tibial plateau fractures: nailing and compression bolts versus modern and traditional plating.
    Lasanianos NG; Garnavos C; Magnisalis E; Kourkoulis S; Babis GC
    Injury; 2013 Oct; 44(10):1333-9. PubMed ID: 23601116
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of conventional versus locking plates in intraarticular calcaneus fractures: a biomechanical study in human cadavers.
    Stoffel K; Booth G; Rohrl SM; Kuster M
    Clin Biomech (Bristol, Avon); 2007 Jan; 22(1):100-5. PubMed ID: 17007974
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Primary stability of an intramedullary calcaneal nail and an angular stable calcaneal plate in a biomechanical testing model of intraarticular calcaneal fracture.
    Goldzak M; Simon P; Mittlmeier T; Chaussemier M; Chiergatti R
    Injury; 2014 Jan; 45 Suppl 1():S49-53. PubMed ID: 24219899
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Internal fixation of experimental intraarticular calcaneal fractures: a biomechanical analysis of two fixation methods.
    Carr JB; Tigges RG; Wayne JS; Earll M
    J Orthop Trauma; 1997 Aug; 11(6):425-8; discussion 428-9. PubMed ID: 9314150
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Minimally invasive treatment of calcaneal fracture by percutaneous leverage, anatomical plate, and compression bolts--the clinical evaluation of cohort of 156 patients.
    Wang Q; Chen W; Su Y; Pan J; Zhang Q; Peng A; Wu X; Wang P; Zhang Y
    J Trauma; 2010 Dec; 69(6):1515-22. PubMed ID: 21150529
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Addition of a suture anchor for coracoclavicular fixation to a superior locking plate improves stability of type IIB distal clavicle fractures.
    Madsen W; Yaseen Z; LaFrance R; Chen T; Awad H; Maloney M; Voloshin I
    Arthroscopy; 2013 Jun; 29(6):998-1004. PubMed ID: 23726106
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Computational Biomechanical Analysis of Postoperative Calcaneal Fractures with Different Placement of the Sustentaculum Screw.
    Qiang MF; Singh RK; Chen YX; Zhang K; Jia XY; Chen S; Wang SG; Wang X; Shi ZM
    Orthop Surg; 2020 Apr; 12(2):661-667. PubMed ID: 32053281
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Long-term results of calcaneal fracture treatment by open reduction and internal fixation using a calcaneal locking compression plate from an extended lateral approach].
    Zeman P; Zeman J; Matejka J; Koudela K
    Acta Chir Orthop Traumatol Cech; 2008 Dec; 75(6):457-64. PubMed ID: 19150004
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical stability of intramedullary technique for fixation of joint depressed calcaneus fracture.
    Nelson JD; McIff TE; Moodie PG; Iverson JL; Horton GA
    Foot Ankle Int; 2010 Mar; 31(3):229-35. PubMed ID: 20230701
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of plates with and without locking screws in a calcaneal fracture model.
    Richter M; Gosling T; Zech S; Allami M; Geerling J; Droste P; Krettek C
    Foot Ankle Int; 2005 Apr; 26(4):309-19. PubMed ID: 15829215
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical evaluation of a locking and nonlocking reconstruction plate in an osteoporotic calcaneal fracture model.
    Blake MH; Owen JR; Sanford TS; Wayne JS; Adelaar RS
    Foot Ankle Int; 2011 Apr; 32(4):432-6. PubMed ID: 21733448
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Operative treatment of intraarticular calcaneal fractures: Anatomical and functional outcome of three different operative techniques.
    Gusic N; Fedel I; Darabos N; Lovric Z; Bukvic N; Bakota B; Lemac D
    Injury; 2015 Nov; 46 Suppl 6():S130-3. PubMed ID: 26606987
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Outcomes of Treatment of Calcaneal Fractures Using Locking Compression Plate with or without Augmentation].
    Zeman J; Matějka T; Zeman P; Belatka J; Matějka J
    Acta Chir Orthop Traumatol Cech; 2019; 86(6):413-418. PubMed ID: 31941568
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical comparison of conventional and optimised locking plates for the fixation of intraarticular calcaneal fractures: a finite element analysis.
    Ouyang H; Deng Y; Xie P; Yang Y; Jiang B; Zeng C; Huang W
    Comput Methods Biomech Biomed Engin; 2017 Sep; 20(12):1339-1349. PubMed ID: 28768423
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.