108 related articles for article (PubMed ID: 22892700)
1. Azygos vein lead implantation: a therapeutic option for elevated defibrillation threshold.
Camanho LE; Silva AC; Teixeira MA; Oliveira Junior LA; Saad EB; Maia Mda C
Arq Bras Cardiol; 2012 Jun; 98(6):e98-e101. PubMed ID: 22892700
[TBL] [Abstract][Full Text] [Related]
2. Azygos vein lead implantation: a novel adjunctive technique for implantable cardioverter defibrillator placement.
Cesario D; Bhargava M; Valderrábano M; Fonarow GC; Wilkoff B; Shivkumar K
J Cardiovasc Electrophysiol; 2004 Jul; 15(7):780-3. PubMed ID: 15250862
[TBL] [Abstract][Full Text] [Related]
3. The azygos defibrillator lead for elevated defibrillation thresholds: implant technique, lead stability, and patient series.
Cooper JA; Latacha MP; Soto GE; Garmany RG; Gleva MJ; Chen J; Faddis MN; Smith TW
Pacing Clin Electrophysiol; 2008 Nov; 31(11):1405-10. PubMed ID: 18950297
[TBL] [Abstract][Full Text] [Related]
4. Successful reduction of a high defibrillation threshold by a combined implantation of a subcutaneous array and azygos vein lead.
Yamada T; Robertson PG; McElderry HT; Doppalapudi H; Plumb VJ; Kay GN
Pacing Clin Electrophysiol; 2012 Jun; 35(6):e173-6. PubMed ID: 22360586
[TBL] [Abstract][Full Text] [Related]
5. Early and frequent defibrillator discharge in patients with cardiac sarcoidosis compared with patients with idiopathic dilated cardiomyopathy.
Takaya Y; Kusano K; Nishii N; Nakamura K; Ito H
Int J Cardiol; 2017 Aug; 240():302-306. PubMed ID: 28438355
[TBL] [Abstract][Full Text] [Related]
6. [Change of defibrillation vector with addition of an azygos vein coil lowers defibrillation threshold].
Jastrzębski M; Czarnecka D
Kardiol Pol; 2012; 70(11):1202-4. PubMed ID: 23180538
[TBL] [Abstract][Full Text] [Related]
7. A biventricular ICD system with biventricular defibrillation.
Spurrell P; Gandhi M; Rinaldi CA
Pacing Clin Electrophysiol; 2006 Mar; 29(3):334-6. PubMed ID: 16606405
[TBL] [Abstract][Full Text] [Related]
8. Implantable Cardioverter Defibrillator Implantation with or Without Defibrillation Testing.
Duffett S; El Hajjaji I; Manlucu J; Yee R
Card Electrophysiol Clin; 2018 Mar; 10(1):119-125. PubMed ID: 29428133
[TBL] [Abstract][Full Text] [Related]
9. A plea for delivery of high-voltage shocks during implantable cardioverter-defibrillator replacement or system upgrade.
Sticherling C; Schaer B; Kühne M; Osswald S
Can J Cardiol; 2012; 28(5):611.e5-6. PubMed ID: 22498180
[TBL] [Abstract][Full Text] [Related]
10. Implantation of additional defibrillation lead into the coronary sinus: an effective method of decreasing defibrillation threshold.
Wilczek R; Swiątkowski M; Czepiel A; Sterliński M; Makowska E; Kułakowski P
Kardiol Pol; 2011; 69(12):1308-9. PubMed ID: 22219117
[TBL] [Abstract][Full Text] [Related]
11. [Idiopathic dilated cardiomyopathy--an appraisal in 2005].
Antz M; Bänsch D
Herz; 2005 Mar; 30(2):87-90. PubMed ID: 15875096
[TBL] [Abstract][Full Text] [Related]
12. Implantation of a unipolar cardioverter/defibrillator system under local anaesthesia.
Stix G; Anvari A; Grabenwöger M; Merhaut C; Türel Z; Laufer G; Schmidinger H
Eur Heart J; 1996 May; 17(5):764-8. PubMed ID: 8737108
[TBL] [Abstract][Full Text] [Related]
13. Assessment of Efficacy and Necessity of Routine Defibrillation Threshold Testing in Patients Undergoing Implantable Cardioverter-Defibrillator (ICD) Implantation.
Ashino S; Nakai T; Sonoda K; Sasaki N; Kurokawa S; Ikeya Y; Okumura Y; Ohkubo K; Kunimoto S; Watanabe I; Hirayama A
Int Heart J; 2015; 56(6):618-21. PubMed ID: 26549282
[TBL] [Abstract][Full Text] [Related]
14. Ventricular tachycardia initiated by high energy cardioversion in a patient with an implantable cardioverter defibrillator.
Chinushi M; Aizawa Y; Higuchi K
Heart; 1997 Apr; 77(4):373-4. PubMed ID: 9155621
[TBL] [Abstract][Full Text] [Related]
15. Defibrillator implantation via the iliac vein.
Pinski SL; Bredikis AJ
Pacing Clin Electrophysiol; 2000 Aug; 23(8):1315-7. PubMed ID: 10962761
[TBL] [Abstract][Full Text] [Related]
16. Hemiazygous coil placement for high-defibrillation thresholds in a patient with a right-sided implantable cardioverter defibrillator.
Nilsson KR; Jackson KP
Pacing Clin Electrophysiol; 2012 Jan; 35(1):e10-2. PubMed ID: 20723090
[TBL] [Abstract][Full Text] [Related]
17. Effects of shock polarity reversal on defibrillation threshold in an implantable cardioverter-defibrillator.
Zienciuk A; Lubiński A; Królak T; Lewicka-Nowak E; Kempa M; Pazdyga A; Raczak G
Kardiol Pol; 2007 May; 65(5):495-500; discussion 501-2. PubMed ID: 17577846
[TBL] [Abstract][Full Text] [Related]
18. Clinical predictors of defibrillation threshold in patients with implantable cardioverter-defibrillators.
Lubiński A; Lewicka-Nowak E; Zienciuk A; Królak T; Kempa M; Pazdyga A; Swiatecka G
Kardiol Pol; 2005 Apr; 62(4):317-28; discussion 329-31. PubMed ID: 15928737
[TBL] [Abstract][Full Text] [Related]
19. Pre-discharge defibrillation testing: Is it still justified?
Kempa M; Królak T; Drelich Ł; Budrejko S; Daniłowicz-Szymanowicz L; Lewicka E; Kozłowski D; Raczak G
Cardiol J; 2016; 23(5):532-538. PubMed ID: 27387062
[TBL] [Abstract][Full Text] [Related]
20. Anesthesia care for subcutaneous implantable cardioverter/defibrillator placement: a single-center experience.
Essandoh MK; Portillo JG; Weiss R; Otey AJ; Zuleta-Alarcon AN; Humeidan ML; Torres JL; Flores AS; Castellon-Larios K; Abdel-Rasoul M; Andritsos MJ; Perez WJ; Stein EJ; Turner KR; Dimitrova GT; Awad H; Bhandary SP; Tripathi RS; Joseph NC; Hummel JD; Augostini RS; Kalbfleisch SJ; Tyler JD; Houmsse M; Daoud EG
J Clin Anesth; 2016 Jun; 31():53-9. PubMed ID: 27185678
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]