These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

86 related articles for article (PubMed ID: 2289790)

  • 1. Optimal design of a thermistor probe for surface measurement of cerebral blood flow.
    Wei DT; Saidel GM; Jones SC
    IEEE Trans Biomed Eng; 1990 Dec; 37(12):1159-72. PubMed ID: 2289790
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Self-heated thermistor measurements of perfusion.
    Anderson GT; Valvano JW; Santos RR
    IEEE Trans Biomed Eng; 1992 Sep; 39(9):877-85. PubMed ID: 1473816
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Effects of probe configuration on the measurement of bio-tissue thermal physical parameters using step-temperature technique].
    Yang K; Liu W; Luo Q
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Oct; 24(5):1001-7. PubMed ID: 18027684
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A sensitivity analysis of the step-temperature technique for measurement of local tissue blood perfusion.
    Yang K; Liu W
    J Med Eng Technol; 2008; 32(1):73-82. PubMed ID: 18183522
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A novel model of the pulse decay method for measurement of local tissue blood perfusion.
    Yang K; Liu W
    Med Eng Phys; 2004 Apr; 26(3):215-23. PubMed ID: 14984843
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Thermal diffusion probe and instrument system for tissue blood flow measurements: validation in phantoms and in vivo organs.
    Delhomme G; Newman WH; Roussel B; Jouvet M; Bowman HF; Dittmar A
    IEEE Trans Biomed Eng; 1994 Jul; 41(7):656-62. PubMed ID: 7927386
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simultaneous measurements of local tissue temperature and blood perfusion rate in the canine prostate during radio frequency thermal therapy.
    Zhu L; Pang L; Xu LX
    Biomech Model Mechanobiol; 2005 Aug; 4(1):1-9. PubMed ID: 15940507
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Finite volume analysis of temperature effects induced by active MRI implants: 2. Defects on active MRI implants causing hot spots.
    Busch MH; Vollmann W; Grönemeyer DH
    Biomed Eng Online; 2006 May; 5():35. PubMed ID: 16729878
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurement of thermal conductivity, thermal diffusivity, and perfusion.
    Yuan DY; Valvano JW; Anderson GT
    Biomed Sci Instrum; 1993; 29():435-42. PubMed ID: 8329624
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of continuous thermal measurement of cerebral blood flow by arterial pressure change.
    Wei D; Shea M; Saidel GM; Jones SC
    J Cereb Blood Flow Metab; 1993 Jul; 13(4):693-701. PubMed ID: 8314922
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The new Licox combined brain tissue oxygen and brain temperature monitor: assessment of in vitro accuracy and clinical experience in severe traumatic brain injury.
    Stewart C; Haitsma I; Zador Z; Hemphill JC; Morabito D; Manley G; Rosenthal G
    Neurosurgery; 2008 Dec; 63(6):1159-64; discussion 1164-5. PubMed ID: 19057329
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Artefacts in intracavitary temperature measurements during regional hyperthermia.
    Kok HP; Van den Berg CA; Van Haaren PM; Crezee J
    Phys Med Biol; 2007 Sep; 52(17):5157-71. PubMed ID: 17762078
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of the time response of the temperature sensor on thermodilution measurements.
    da Rocha AF; dos Santos I; Nascimento FA; Melo MD; Haemmerich D; Valvano JW
    Physiol Meas; 2005 Dec; 26(6):885-901. PubMed ID: 16311439
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro and in vivo studies on thermistor-based intracoronary temperature measurements: effect of pressure and flow.
    Cuisset T; Beauloye C; Melikian N; Hamilos M; Sarma J; Sarno G; Naslund M; Smith L; Van de Vosse F; Pijls NH; De Bruyne B
    Catheter Cardiovasc Interv; 2009 Feb; 73(2):224-30. PubMed ID: 19156891
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High resolution multi-temperature sensors for biomedical application.
    Urban G; Jachimowicz A; Kohl F; Kuttner H; Olcaytug F; Goiser P; Lindner K; Pockberger H; Prohaska O; Schönauer M
    Med Prog Technol; 1990; 16(3):173-81. PubMed ID: 2146481
    [TBL] [Abstract][Full Text] [Related]  

  • 16. New constant-temperature operating mode for graphite calorimeter at LNE-LNHB.
    Daures J; Ostrowsky A
    Phys Med Biol; 2005 Sep; 50(17):4035-52. PubMed ID: 16177528
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cortical thermal clearance as a predictor of imminent neurological deterioration.
    Choksey MS
    Cerebrovasc Brain Metab Rev; 1996; 8(3):230-71. PubMed ID: 8870976
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Expiratory ventilation and carbon dioxide production measured with a thermistor flow-through system].
    Nagashima T
    Nihon Kyobu Shikkan Gakkai Zasshi; 1996 Mar; 34(3):281-9. PubMed ID: 8778467
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Design and fabrication development of a micro flow heated channel with measurements of the inside micro-scale flow and heat transfer process.
    Liu CW; Gau C; Dai BT
    Biosens Bioelectron; 2004 Jul; 20(1):91-101. PubMed ID: 15142581
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Highly accurate thermal flow microsensor for continuous and quantitative measurement of cerebral blood flow.
    Li C; Wu PM; Wu Z; Limnuson K; Mehan N; Mozayan C; Golanov EV; Ahn CH; Hartings JA; Narayan RK
    Biomed Microdevices; 2015 Oct; 17(5):87. PubMed ID: 26256480
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.