These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
25. Investigation of power and frequency for 3D conformal MRI-controlled transurethral ultrasound therapy with a dual frequency multi-element transducer. N'djin WA; Burtnyk M; Bronskill M; Chopra R Int J Hyperthermia; 2012; 28(1):87-104. PubMed ID: 22235788 [TBL] [Abstract][Full Text] [Related]
26. A thermal beam-shape phantom for ultrasound physiotherapy transducers. Martin K; Fernandez R Ultrasound Med Biol; 1997; 23(8):1267-74. PubMed ID: 9372575 [TBL] [Abstract][Full Text] [Related]
27. [Metrological problems in testing medical ultrasound equipment]. Eniakov AM Med Tekh; 2001; (3):20-1. PubMed ID: 11515262 [TBL] [Abstract][Full Text] [Related]
28. Circumferential lesion formation around the pulmonary veins in the left atrium with focused ultrasound using a 2D-array endoesophageal device: a numerical study. Pichardo S; Hynynen K Phys Med Biol; 2007 Aug; 52(16):4923-42. PubMed ID: 17671344 [TBL] [Abstract][Full Text] [Related]
29. Combination of thermal and cavitation effects to generate deep lesions with an endocavitary applicator using a plane transducer: ex vivo studies. Melodelima D; Chapelon JY; Theillère Y; Cathignol D Ultrasound Med Biol; 2004 Jan; 30(1):103-11. PubMed ID: 14962614 [TBL] [Abstract][Full Text] [Related]
30. Backward Data Transfer From Deeply Implanted Device Employing Ultrasonic Load Amplitude-Phase Shift Keying. Ozeri S; Amrani O IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Jan; 69(1):199-207. PubMed ID: 34623265 [TBL] [Abstract][Full Text] [Related]
31. Analytical and numerical calculations of optimum design frequency for focused ultrasound therapy and acoustic radiation force. Ergün AS Ultrasonics; 2011 Oct; 51(7):786-94. PubMed ID: 21459399 [TBL] [Abstract][Full Text] [Related]
32. Noninvasive measurement of local thermal diffusivity using backscattered ultrasound and focused ultrasound heating. Anand A; Kaczkowski PJ Ultrasound Med Biol; 2008 Sep; 34(9):1449-64. PubMed ID: 18450361 [TBL] [Abstract][Full Text] [Related]
33. Distant energy transfer for artificial human implants. Theodoridis MP; Mollov SV IEEE Trans Biomed Eng; 2005 Nov; 52(11):1931-8. PubMed ID: 16285397 [TBL] [Abstract][Full Text] [Related]
34. The effect of back reflections on the acoustic power delivered by physiotherapy ultrasound machines. McBride KA; Pye SD Ultrasound Med Biol; 2009 Oct; 35(10):1672-8. PubMed ID: 19679389 [TBL] [Abstract][Full Text] [Related]
35. A buoyancy method for the measurement of total ultrasound power generated by HIFU transducers. Shaw A Ultrasound Med Biol; 2008 Aug; 34(8):1327-42. PubMed ID: 18471952 [TBL] [Abstract][Full Text] [Related]
36. Simulations and measurements of transcranial low-frequency ultrasound therapy: skull-base heating and effective area of treatment. Pulkkinen A; Huang Y; Song J; Hynynen K Phys Med Biol; 2011 Aug; 56(15):4661-83. PubMed ID: 21734333 [TBL] [Abstract][Full Text] [Related]
37. Progress in developing a thermal method for measuring the output power of medical ultrasound transducers that exploits the pyroelectric effect. Zeqiri B; Zauhar G; Hodnett M; Barrie J Ultrasonics; 2011 May; 51(4):420-4. PubMed ID: 21163509 [TBL] [Abstract][Full Text] [Related]
38. Lens-focused transducer modeling using an extended KLM model. Maréchal P; Levassort F; Tran-Huu-Hue LP; Lethiecq M Ultrasonics; 2007 May; 46(2):155-67. PubMed ID: 17382986 [TBL] [Abstract][Full Text] [Related]
39. Modelling of heat and mass transfer processes in neonatology. Ginalski MK; Nowak AJ; Wrobel LC Biomed Mater; 2008 Sep; 3(3):034113. PubMed ID: 18708705 [TBL] [Abstract][Full Text] [Related]
40. Minimizing the thermal losses from perfusion during focused ultrasound exposures with flowing microbubbles. Zhang S; Ding T; Wan M; Jiang H; Yang X; Zhong H; Wang S J Acoust Soc Am; 2011 Apr; 129(4):2336-44. PubMed ID: 21476689 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]