189 related articles for article (PubMed ID: 22904606)
1. The Latest Lessons Learned from Retrieval Analyses of Ultra-High Molecular Weight Polyethylene, Metal-on-Metal, and Alternative Bearing Total Disc Replacements.
Kurtz SM; Toth JM; Siskey R; Ciccarelli L; Macdonald D; Isaza J; Lanman T; Punt I; Steinbeck M; Goffin J; van Ooij A
Semin Spine Surg; 2012 Mar; 24(1):57-70. PubMed ID: 22904606
[TBL] [Abstract][Full Text] [Related]
2. Are PEEK-on-Ceramic Bearings an Option for Total Disc Arthroplasty? An In Vitro Tribology Study.
Siskey R; Ciccarelli L; Lui MK; Kurtz SM
Clin Orthop Relat Res; 2016 Nov; 474(11):2428-2440. PubMed ID: 27677290
[TBL] [Abstract][Full Text] [Related]
3. UHMWPE wear debris and tissue reactions are reduced for contemporary designs of lumbar total disc replacements.
Veruva SY; Lanman TH; Isaza JE; MacDonald DW; Kurtz SM; Steinbeck MJ
Clin Orthop Relat Res; 2015 Mar; 473(3):987-98. PubMed ID: 25367112
[TBL] [Abstract][Full Text] [Related]
4. Development of a clinically relevant impingement test method for a mobile bearing lumbar total disc replacement.
Siskey R; Peck J; Mehta H; Kosydar A; Kurtz S; Hill G
Spine J; 2016 Sep; 16(9):1133-42. PubMed ID: 27179625
[TBL] [Abstract][Full Text] [Related]
5. Retrieval analysis of motion preserving spinal devices and periprosthetic tissues.
Kurtz SM; Steinbeck M; Ianuzzi A; van Ooij A; Punt IM; Isaza J; Ross ER
SAS J; 2009; 3(4):161-77. PubMed ID: 25802641
[TBL] [Abstract][Full Text] [Related]
6. Which design and biomaterial factors affect clinical wear performance of total disc replacements? A systematic review.
Veruva SY; Steinbeck MJ; Toth J; Alexander DD; Kurtz SM
Clin Orthop Relat Res; 2014 Dec; 472(12):3759-69. PubMed ID: 25002211
[TBL] [Abstract][Full Text] [Related]
7. Biomaterial optimization in total disc arthroplasty.
Hallab N; Link HD; McAfee PC
Spine (Phila Pa 1976); 2003 Oct; 28(20):S139-52. PubMed ID: 14560185
[TBL] [Abstract][Full Text] [Related]
8. In vivo functional performance of failed Prodisc-L devices: retrieval analysis of lumbar total disc replacements.
Lebl DR; Cammisa FP; Girardi FP; Wright T; Abjornson C
Spine (Phila Pa 1976); 2012 Sep; 37(19):E1209-17. PubMed ID: 22531474
[TBL] [Abstract][Full Text] [Related]
9. Comparison of in vivo and simulator-retrieved metal-on-metal cervical disc replacements.
Kurtz SM; Ciccarelli L; Harper ML; Siskey R; Shorez J; Chan FW
Int J Spine Surg; 2012; 6():145-56. PubMed ID: 25694884
[TBL] [Abstract][Full Text] [Related]
10. Response of Charité total disc replacement under physiologic loads: prosthesis component motion patterns.
O'Leary P; Nicolakis M; Lorenz MA; Voronov LI; Zindrick MR; Ghanayem A; Havey RM; Carandang G; Sartori M; Gaitanis IN; Fronczak S; Patwardhan AG
Spine J; 2005; 5(6):590-9. PubMed ID: 16291097
[TBL] [Abstract][Full Text] [Related]
11. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements.
Clarke IC; Good V; Williams P; Schroeder D; Anissian L; Stark A; Oonishi H; Schuldies J; Gustafson G
Proc Inst Mech Eng H; 2000; 214(4):331-47. PubMed ID: 10997055
[TBL] [Abstract][Full Text] [Related]
12. Polyethylene wear and rim fracture in total disc arthroplasty.
Kurtz SM; van Ooij A; Ross R; de Waal Malefijt J; Peloza J; Ciccarelli L; Villarraga ML
Spine J; 2007; 7(1):12-21. PubMed ID: 17197327
[TBL] [Abstract][Full Text] [Related]
13. Fluoroscopic assessment of lumbar total disc replacement kinematics during walking.
Barrett RS; Lichtwark GA; Armstrong C; Barber L; Scott-Young M; Hall RM
Spine (Phila Pa 1976); 2015 Apr; 40(7):436-42. PubMed ID: 25599285
[TBL] [Abstract][Full Text] [Related]
14. The natural history of polyethylene oxidation in total disc replacement.
Kurtz SM; MacDonald D; Ianuzzi A; van Ooij A; Isaza J; Ross ER; Regan J
Spine (Phila Pa 1976); 2009 Oct; 34(22):2369-77. PubMed ID: 19789469
[TBL] [Abstract][Full Text] [Related]
15. Comparison of 2 lumbar total disc replacements: results of a prospective, randomized, controlled, multicenter Food and Drug Administration trial with 24-month follow-up.
Guyer RD; Pettine K; Roh JS; Dimmig TA; Coric D; McAfee PC; Ohnmeiss DD
Spine (Phila Pa 1976); 2014 May; 39(12):925-31. PubMed ID: 24718066
[TBL] [Abstract][Full Text] [Related]
16. Material and surface factors influencing backside fretting wear in total knee replacement tibial components.
Billi F; Sangiorgio SN; Aust S; Ebramzadeh E
J Biomech; 2010 May; 43(7):1310-5. PubMed ID: 20172525
[TBL] [Abstract][Full Text] [Related]
17. Asymmetric motion distribution between components of a mobile-core lumbar disc prosthesis: an explanation of unequal wear distribution in explanted CHARITÉ polyethylene cores.
Patwardhan AG; Havey RM; Wharton ND; Tsitsopoulos PP; Newman P; Carandang G; Voronov LI
J Bone Joint Surg Am; 2012 May; 94(9):846-54. PubMed ID: 22552675
[TBL] [Abstract][Full Text] [Related]
18. Polyethylene wear debris and long-term clinical failure of the Charité disc prosthesis: a study of 4 patients.
van Ooij A; Kurtz SM; Stessels F; Noten H; van Rhijn L
Spine (Phila Pa 1976); 2007 Jan; 32(2):223-9. PubMed ID: 17224818
[TBL] [Abstract][Full Text] [Related]
19. Strain behavior of malaligned cervical spine implanted with metal-on-polyethylene, metal-on-metal, and elastomeric artificial disc prostheses - A finite element analysis.
Chen WM; Jin J; Park T; Ryu KS; Lee SJ
Clin Biomech (Bristol, Avon); 2018 Nov; 59():19-26. PubMed ID: 30119037
[TBL] [Abstract][Full Text] [Related]
20. Bearing surfaces for total disc arthroplasty: metal-on-metal versus metal-on-polyethylene and other biomaterials.
Golish SR; Anderson PA
Spine J; 2012 Aug; 12(8):693-701. PubMed ID: 21700505
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]