BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

659 related articles for article (PubMed ID: 22917636)

  • 1. A new low-volume isosmotic polyethylene glycol solution plus bisacodyl versus split-dose 4 L polyethylene glycol for bowel cleansing prior to colonoscopy: a randomised controlled trial.
    Cesaro P; Hassan C; Spada C; Petruzziello L; Vitale G; Costamagna G
    Dig Liver Dis; 2013 Jan; 45(1):23-7. PubMed ID: 22917636
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Randomised clinical trial: low-volume bowel preparation for colonoscopy - a comparison between two different PEG-based formulations.
    Repici A; Cestari R; Annese V; Biscaglia G; Vitetta E; Minelli L; Trallori G; Orselli S; Andriulli A; Hassan C
    Aliment Pharmacol Ther; 2012 Oct; 36(8):717-24. PubMed ID: 22924336
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 2-Litre polyethylene glycol-citrate-simethicone plus bisacodyl versus 4-litre polyethylene glycol as preparation for colonoscopy in chronic constipation.
    Parente F; Vailati C; Bargiggia S; Manes G; Fontana P; Masci E; Arena M; Spinzi G; Baccarin A; Mazzoleni G; Testoni PA
    Dig Liver Dis; 2015 Oct; 47(10):857-63. PubMed ID: 26232311
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A dual-action, low-volume bowel cleanser administered the day before colonoscopy: results from the SEE CLEAR II study.
    Katz PO; Rex DK; Epstein M; Grandhi NK; Vanner S; Hookey LC; Alderfer V; Joseph RE
    Am J Gastroenterol; 2013 Mar; 108(3):401-9. PubMed ID: 23318484
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A prospective audit of the efficacy, safety, and acceptability of low-volume polyethylene glycol (2 L) versus standard volume polyethylene glycol (4 L) versus magnesium citrate plus stimulant laxative as bowel preparation for colonoscopy.
    Kelly NM; Rodgers C; Patterson N; Jacob SG; Mainie I
    J Clin Gastroenterol; 2012 Aug; 46(7):595-601. PubMed ID: 22334219
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The use of low-volume polyethylene glycol containing ascorbic acid versus 2 L of polyethylene glycol plus bisacodyl as bowel preparation for colonoscopy.
    Tae CH; Jung SA; Na SK; Song HK; Moon CM; Kim SE; Shim KN; Jung HK; Moon IH
    Scand J Gastroenterol; 2015 Aug; 50(8):1039-44. PubMed ID: 25862428
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Preparation before colonoscopy: a randomized controlled trial comparing different regimes.
    Jansen SV; Goedhard JG; Winkens B; van Deursen CT
    Eur J Gastroenterol Hepatol; 2011 Oct; 23(10):897-902. PubMed ID: 21900786
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Split-dose administration of a dual-action, low-volume bowel cleanser for colonoscopy: the SEE CLEAR I study.
    Rex DK; Katz PO; Bertiger G; Vanner S; Hookey LC; Alderfer V; Joseph RE
    Gastrointest Endosc; 2013 Jul; 78(1):132-41. PubMed ID: 23566639
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Efficacy and Safety of Sodium Picosulfate/Magnesium Citrate for Bowel Preparation in a Physically Disabled Outpatient Population: A Randomized, Endoscopist-Blinded Comparison With Ascorbic Acid-Enriched Polyethylene Glycol Solution Plus Bisacodyl (The PICO-MOVI Study).
    Mathus-Vliegen EMH; van der Vliet K; Wignand-van der Storm IJ; Stadwijk JS
    Dis Colon Rectum; 2018 Feb; 61(2):239-249. PubMed ID: 29337780
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of a split-dose bowel preparation with 2 liters of polyethylene glycol plus ascorbic acid and 1 liter of polyethylene glycol plus ascorbic acid and bisacodyl before colonoscopy.
    Kang SH; Jeen YT; Lee JH; Yoo IK; Lee JM; Kim SH; Choi HS; Kim ES; Keum B; Lee HS; Chun HJ; Kim CD
    Gastrointest Endosc; 2017 Aug; 86(2):343-348. PubMed ID: 27889546
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical trial: an efficacy evaluation of reduced bisacodyl given as part of a polyethylene glycol electrolyte solution preparation prior to colonoscopy.
    DiPalma JA; McGowan J; Cleveland MV
    Aliment Pharmacol Ther; 2007 Oct; 26(8):1113-9. PubMed ID: 17894653
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Efficacy and acceptability of sodium picosulphate/magnesium citrate vs low-volume polyethylene glycol plus ascorbic acid for colon cleansing: a randomized controlled trial.
    Manes G; Amato A; Arena M; Pallotta S; Radaelli F; Masci E
    Colorectal Dis; 2013 Sep; 15(9):1145-53. PubMed ID: 23581277
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clinical trial: sodium phosphate tablets are preferred and better tolerated by patients compared to polyethylene glycol solution plus bisacodyl tablets for bowel preparation.
    Lichtenstein GR; Grandhi N; Schmalz M; Lottes SR; Forbes WP; Walker K; Zhang B
    Aliment Pharmacol Ther; 2007 Nov; 26(10):1361-70. PubMed ID: 17983368
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bowel preparations for colonoscopy: an RCT.
    Di Nardo G; Aloi M; Cucchiara S; Spada C; Hassan C; Civitelli F; Nuti F; Ziparo C; Pession A; Lima M; La Torre G; Oliva S
    Pediatrics; 2014 Aug; 134(2):249-56. PubMed ID: 25002661
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bisacodyl plus split 2-L polyethylene glycol-citrate-simethicone improves quality of bowel preparation before screening colonoscopy.
    Valiante F; Bellumat A; De Bona M; De Boni M
    World J Gastroenterol; 2013 Sep; 19(33):5493-9. PubMed ID: 24023492
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A low-volume polyethylene glycol plus ascorbate solution for bowel cleansing prior to colonoscopy: the NORMO randomised clinical trial.
    Ponchon T; Boustière C; Heresbach D; Hagege H; Tarrerias AL; Halphen M
    Dig Liver Dis; 2013 Oct; 45(10):820-6. PubMed ID: 23769755
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prospective, randomized comparison of same-day dose of 2 different bowel cleanser for afternoon colonoscopy: picosulfate, magnesium oxide, and citric acid versus polyethylene glycol.
    Gweon TG; Kim SW; Noh YS; Hwang S; Kim NY; Lee Y; Lee SW; Lee SW; Lee JY; Lim CH; Hun Kim H; Kim JS; Kyung Cho Y; Myung Park J; Seok Lee I; Myung-Gyu Choi
    Medicine (Baltimore); 2015 Apr; 94(13):e628. PubMed ID: 25837751
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Orange juice intake reduces patient discomfort and is effective for bowel cleansing with polyethylene glycol during bowel preparation.
    Choi HS; Shim CS; Kim GW; Kim JS; Lee SY; Sung IK; Park HS; Kim JH
    Dis Colon Rectum; 2014 Oct; 57(10):1220-7. PubMed ID: 25203380
    [TBL] [Abstract][Full Text] [Related]  

  • 19. 2 L versus 4 L of PEG3350 + electrolytes for outpatient colonic preparation: a randomized, controlled trial.
    Brahmania M; Ou G; Bressler B; Ko HK; Lam E; Telford J; Enns R
    Gastrointest Endosc; 2014 Mar; 79(3):408-416.e4. PubMed ID: 24206747
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of asymmetric (low morning-dose) and standard split-dose regimen of PEG plus bisacodyl for bowel preparation: A randomized controlled trial.
    Andreozzi P; De Nucci G; Bezzio C; Arena I; Devani M; Mandelli E; Morganti D; Omazzi B; Reati R; Redaelli D; Saibeni S; Manes G
    Dig Liver Dis; 2019 Jun; 51(6):837-842. PubMed ID: 30658942
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 33.