483 related articles for article (PubMed ID: 22922113)
1. An amperometric glutathione biosensor based on chitosan-iron coated gold nanoparticles modified Pt electrode.
Chauhan N; Narang J; Meena ; Pundir CS
Int J Biol Macromol; 2012 Dec; 51(5):879-86. PubMed ID: 22922113
[TBL] [Abstract][Full Text] [Related]
2. Silver nanoparticles/multiwalled carbon nanotube/polyaniline film for amperometric glutathione biosensor.
Narang J; Chauhan N; Jain P; Pundir CS
Int J Biol Macromol; 2012 Apr; 50(3):672-8. PubMed ID: 22300999
[TBL] [Abstract][Full Text] [Related]
3. Immobilization of creatininase, creatinase and sarcosine oxidase on iron oxide nanoparticles/chitosan-g-polyaniline modified Pt electrode for detection of creatinine.
Yadav S; Devi R; Bhar P; Singhla S; Pundir CS
Enzyme Microb Technol; 2012 Apr; 50(4-5):247-54. PubMed ID: 22418265
[TBL] [Abstract][Full Text] [Related]
4. Amperometric determination of acetylcholine-A neurotransmitter, by chitosan/gold-coated ferric oxide nanoparticles modified gold electrode.
Chauhan N; Pundir CS
Biosens Bioelectron; 2014 Nov; 61():1-8. PubMed ID: 24836212
[TBL] [Abstract][Full Text] [Related]
5. An amperometric glutamate biosensor based on immobilization of glutamate oxidase onto carboxylated multiwalled carbon nanotubes/gold nanoparticles/chitosan composite film modified Au electrode.
Batra B; Pundir CS
Biosens Bioelectron; 2013 Sep; 47():496-501. PubMed ID: 23628843
[TBL] [Abstract][Full Text] [Related]
6. Development of amperometric lysine biosensors based on Au nanoparticles/multiwalled carbon nanotubes/polymers modified Au electrodes.
Chauhan N; Singh A; Narang J; Dahiya S; Pundir CS
Analyst; 2012 Nov; 137(21):5113-22. PubMed ID: 22986735
[TBL] [Abstract][Full Text] [Related]
7. A novel glucose biosensor based on immobilization of glucose oxidase in chitosan on a glassy carbon electrode modified with gold-platinum alloy nanoparticles/multiwall carbon nanotubes.
Kang X; Mai Z; Zou X; Cai P; Mo J
Anal Biochem; 2007 Oct; 369(1):71-9. PubMed ID: 17678866
[TBL] [Abstract][Full Text] [Related]
8. An electrochemical sulfite biosensor based on gold coated magnetic nanoparticles modified gold electrode.
Rawal R; Chawla S; Pundir CS
Biosens Bioelectron; 2012 Jan; 31(1):144-50. PubMed ID: 22035973
[TBL] [Abstract][Full Text] [Related]
9. Immobilization of lysine oxidase on a gold-platinum nanoparticles modified Au electrode for detection of lysine.
Chauhan N; Narang J; Sunny ; Pundir CS
Enzyme Microb Technol; 2013 Apr; 52(4-5):265-71. PubMed ID: 23540929
[TBL] [Abstract][Full Text] [Related]
10. An amperometric biosensor based on laccase immobilized onto MnO2NPs/cMWCNT/PANI modified Au electrode.
Rawal R; Chawla S; Malik P; Pundir CS
Int J Biol Macromol; 2012; 51(1-2):175-81. PubMed ID: 22142791
[TBL] [Abstract][Full Text] [Related]
11. A high-sensitive amperometric hydrogen peroxide biosensor based on the immobilization of hemoglobin on gold colloid/L-cysteine/gold colloid/nanoparticles Pt-chitosan composite film-modified platinum disk electrode.
Yang G; Yuan R; Chai YQ
Colloids Surf B Biointerfaces; 2008 Jan; 61(1):93-100. PubMed ID: 17855061
[TBL] [Abstract][Full Text] [Related]
12. Construction of an amperometric bilirubin biosensor based on covalent immobilization of bilirubin oxidase onto zirconia coated silica nanoparticles/chitosan hybrid film.
Batra B; Lata S; Sunny ; Rana JS; Pundir CS
Biosens Bioelectron; 2013 Jun; 44():64-9. PubMed ID: 23395724
[TBL] [Abstract][Full Text] [Related]
13. Amperometric determination of total phenolic content in wine by laccase immobilized onto silver nanoparticles/zinc oxide nanoparticles modified gold electrode.
Chawla S; Rawal R; Kumar D; Pundir CS
Anal Biochem; 2012 Nov; 430(1):16-23. PubMed ID: 22863983
[TBL] [Abstract][Full Text] [Related]
14. An amperometric biosensor based on acetylcholinesterase immobilized onto iron oxide nanoparticles/multi-walled carbon nanotubes modified gold electrode for measurement of organophosphorus insecticides.
Chauhan N; Pundir CS
Anal Chim Acta; 2011 Sep; 701(1):66-74. PubMed ID: 21763810
[TBL] [Abstract][Full Text] [Related]
15. Development of an amperometric sulfite biosensor based on a gold nanoparticles/chitosan/multiwalled carbon nanotubes/polyaniline-modified gold electrode.
Rawal R; Chawla S; Dahiya T; Pundir CS
Anal Bioanal Chem; 2011 Nov; 401(8):2599-608. PubMed ID: 21877188
[TBL] [Abstract][Full Text] [Related]
16. Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode.
Wu BY; Hou SH; Yin F; Li J; Zhao ZX; Huang JD; Chen Q
Biosens Bioelectron; 2007 Jan; 22(6):838-44. PubMed ID: 16675215
[TBL] [Abstract][Full Text] [Related]
17. An amperometric hypoxanthine biosensor based on Au@FeNPs for determination of hypoxanthine in meat samples.
Devi R; Yadav S; Nehra R; Pundir CS
Int J Biol Macromol; 2013 Nov; 62():629-35. PubMed ID: 24140402
[TBL] [Abstract][Full Text] [Related]
18. An amperometric biosensor based on laccase immobilized onto Fe₃O₄NPs/cMWCNT/PANI/Au electrode for determination of phenolic content in tea leaves extract.
Rawal R; Chawla S; Devender ; Pundir CS
Enzyme Microb Technol; 2012 Sep; 51(4):179-85. PubMed ID: 22883551
[TBL] [Abstract][Full Text] [Related]
19. Construction of amperometric uric acid biosensor based on uricase immobilized on PBNPs/cMWCNT/PANI/Au composite.
Rawal R; Chawla S; Chauhan N; Dahiya T; Pundir CS
Int J Biol Macromol; 2012 Jan; 50(1):112-8. PubMed ID: 22020190
[TBL] [Abstract][Full Text] [Related]
20. Immobilizing Pt nanoparticles and chitosan hybrid film on polyaniline naofibers membrane for an amperometric hydrogen peroxide biosensor.
Chen S; Fu P; Yin B; Yuan R; Chai Y; Xiang Y
Bioprocess Biosyst Eng; 2011 Aug; 34(6):711-9. PubMed ID: 21318624
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]