BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

410 related articles for article (PubMed ID: 22925606)

  • 1. Increased BOLD sensitivity in the orbitofrontal cortex using slice-dependent echo times at 3 T.
    Domsch S; Linke J; Heiler PM; Kroll A; Flor H; Wessa M; Schad LR
    Magn Reson Imaging; 2013 Feb; 31(2):201-11. PubMed ID: 22925606
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dependence of amygdala activation on echo time: results from olfactory fMRI experiments.
    Stöcker T; Kellermann T; Schneider F; Habel U; Amunts K; Pieperhoff P; Zilles K; Shah NJ
    Neuroimage; 2006 Mar; 30(1):151-9. PubMed ID: 16305825
    [TBL] [Abstract][Full Text] [Related]  

  • 3. BOLD sensitivity and SNR characteristics of parallel imaging-accelerated single-shot multi-echo EPI for fMRI.
    Bhavsar S; Zvyagintsev M; Mathiak K
    Neuroimage; 2014 Jan; 84():65-75. PubMed ID: 23954488
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Compensation of susceptibility-induced BOLD sensitivity losses in echo-planar fMRI imaging.
    Deichmann R; Josephs O; Hutton C; Corfield DR; Turner R
    Neuroimage; 2002 Jan; 15(1):120-35. PubMed ID: 11771980
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimal EPI parameters for reduction of susceptibility-induced BOLD sensitivity losses: a whole-brain analysis at 3 T and 1.5 T.
    Weiskopf N; Hutton C; Josephs O; Deichmann R
    Neuroimage; 2006 Nov; 33(2):493-504. PubMed ID: 16959495
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optimized EPI for fMRI studies of the orbitofrontal cortex.
    Deichmann R; Gottfried JA; Hutton C; Turner R
    Neuroimage; 2003 Jun; 19(2 Pt 1):430-41. PubMed ID: 12814592
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Spinal cord functional MRI at 3 T: gradient echo echo-planar imaging versus turbo spin echo.
    Bouwman CJ; Wilmink JT; Mess WH; Backes WH
    Neuroimage; 2008 Nov; 43(2):288-96. PubMed ID: 18706507
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Positive or negative blips? The effect of phase encoding scheme on susceptibility-induced signal losses in EPI.
    De Panfilis C; Schwarzbauer C
    Neuroimage; 2005 Mar; 25(1):112-21. PubMed ID: 15734348
    [TBL] [Abstract][Full Text] [Related]  

  • 9. BOLD contrast sensitivity enhancement and artifact reduction with multiecho EPI: parallel-acquired inhomogeneity-desensitized fMRI.
    Poser BA; Versluis MJ; Hoogduin JM; Norris DG
    Magn Reson Med; 2006 Jun; 55(6):1227-35. PubMed ID: 16680688
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Single-shot compensation of image distortions and BOLD contrast optimization using multi-echo EPI for real-time fMRI.
    Weiskopf N; Klose U; Birbaumer N; Mathiak K
    Neuroimage; 2005 Feb; 24(4):1068-79. PubMed ID: 15670684
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimized 3 T EPI of the amygdalae.
    Robinson S; Windischberger C; Rauscher A; Moser E
    Neuroimage; 2004 May; 22(1):203-10. PubMed ID: 15110010
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spatial sensitivity and temporal response of spin echo and gradient echo bold contrast at 3 T using peak hemodynamic activation time.
    Hulvershorn J; Bloy L; Gualtieri EE; Leigh JS; Elliott MA
    Neuroimage; 2005 Jan; 24(1):216-23. PubMed ID: 15588613
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimized EPI for fMRI using a slice-dependent template-based gradient compensation method to recover local susceptibility-induced signal loss.
    Rick J; Speck O; Maier S; Tüscher O; Dössel O; Hennig J; Zaitsev M
    MAGMA; 2010 Jun; 23(3):165-76. PubMed ID: 20490606
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of slice order and thickness on fMRI activation data using multislice echo-planar imaging.
    Howseman AM; Grootoonk S; Porter DA; Ramdeen J; Holmes AP; Turner R
    Neuroimage; 1999 Apr; 9(4):363-76. PubMed ID: 10191165
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Whole brain, high resolution multiband spin-echo EPI fMRI at 7 T: a comparison with gradient-echo EPI using a color-word Stroop task.
    Boyacioğlu R; Schulz J; Müller NC; Koopmans PJ; Barth M; Norris DG
    Neuroimage; 2014 Aug; 97():142-50. PubMed ID: 24736172
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Minimization of Nyquist ghosting for echo-planar imaging at ultra-high fields based on a "negative readout gradient" strategy.
    van der Zwaag W; Marques JP; Lei H; Just N; Kober T; Gruetter R
    J Magn Reson Imaging; 2009 Nov; 30(5):1171-8. PubMed ID: 19856451
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of spatial BOLD sensitivity variations in fMRI using gradient-echo field maps.
    Mannfolk P; Wirestam R; Nilsson M; van Westen D; Ståhlberg F; Olsrud J
    Magn Reson Imaging; 2010 Sep; 28(7):947-56. PubMed ID: 20573463
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Parallel imaging with asymmetric acceleration to reduce Gibbs artifacts and to increase signal-to-noise ratio of the gradient echo echo-planar imaging sequence for functional MRI.
    Jung KJ; Zhao T
    Magn Reson Med; 2012 Feb; 67(2):419-27. PubMed ID: 21713976
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimized EPI for fMRI studies of the orbitofrontal cortex: compensation of susceptibility-induced gradients in the readout direction.
    Weiskopf N; Hutton C; Josephs O; Turner R; Deichmann R
    MAGMA; 2007 Feb; 20(1):39-49. PubMed ID: 17268781
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An investigation of the value of spin-echo-based fMRI using a Stroop color-word matching task and EPI at 3 T.
    Norris DG; Zysset S; Mildner T; Wiggins CJ
    Neuroimage; 2002 Mar; 15(3):719-26. PubMed ID: 11848715
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.