These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

276 related articles for article (PubMed ID: 22926492)

  • 41. Adverse reaction to metal debris following hip resurfacing: the influence of component type, orientation and volumetric wear.
    Langton DJ; Joyce TJ; Jameson SS; Lord J; Van Orsouw M; Holland JP; Nargol AV; De Smet KA
    J Bone Joint Surg Br; 2011 Feb; 93(2):164-71. PubMed ID: 21282753
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Hip resurfacing versus total hip arthroplasty: a systematic review comparing standardized outcomes.
    Marshall DA; Pykerman K; Werle J; Lorenzetti D; Wasylak T; Noseworthy T; Dick DA; O'Connor G; Sundaram A; Heintzbergen S; Frank C
    Clin Orthop Relat Res; 2014 Jul; 472(7):2217-30. PubMed ID: 24700446
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Cobalt and chromium levels in blood and urine following hip resurfacing arthroplasty with the Conserve Plus implant.
    Kim PR; Beaulé PE; Dunbar M; Lee JK; Birkett N; Turner MC; Yenugadhati N; Armstrong V; Krewski D
    J Bone Joint Surg Am; 2011 May; 93 Suppl 2():107-17. PubMed ID: 21543699
    [TBL] [Abstract][Full Text] [Related]  

  • 44. The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial.
    Garbuz DS; Tanzer M; Greidanus NV; Masri BA; Duncan CP
    Clin Orthop Relat Res; 2010 Feb; 468(2):318-25. PubMed ID: 19697090
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The Relationship Between Cobalt/Chromium Ratios and the High Prevalence of Head-Stem Junction Corrosion in Metal-on-Metal Total Hip Arthroplasty.
    Hothi HS; Berber R; Whittaker RK; Blunn GW; Skinner JA; Hart AJ
    J Arthroplasty; 2016 May; 31(5):1123-7. PubMed ID: 26796774
    [TBL] [Abstract][Full Text] [Related]  

  • 46. The 2012 Otto Aufranc Award: The interpretation of metal ion levels in unilateral and bilateral hip resurfacing.
    Van Der Straeten C; Grammatopoulos G; Gill HS; Calistri A; Campbell P; De Smet KA
    Clin Orthop Relat Res; 2013 Feb; 471(2):377-85. PubMed ID: 22930211
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Hip Resurfacing Compared with 28-mm Metal-on-Metal Total Hip Replacement: A Randomized Study with 15 Years of Follow-up.
    Vendittoli PA; Shahin M; Rivière C; Roy AG; Barry J; Lavigne M
    J Bone Joint Surg Am; 2020 Nov; 102(Suppl 2):80-90. PubMed ID: 32554999
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Metal ion levels not sufficient as a screening measure for adverse reactions in metal-on-metal hip arthroplasties.
    Macnair RD; Wynn-Jones H; Wimhurst JA; Toms A; Cahir J
    J Arthroplasty; 2013 Jan; 28(1):78-83. PubMed ID: 22771092
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Two-year serum metal ion levels in minimally invasive total conservative hip resurfacing: preliminary results of a prospective study.
    Tai SM; Millard N; Munir S; Jenabzadeh AR; Walter LR; Walter WL
    ANZ J Surg; 2015 Mar; 85(3):164-8. PubMed ID: 25288230
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-on-metal hip resurfacing.
    Hart AJ; Buddhdev P; Winship P; Faria N; Powell JJ; Skinner JA
    Hip Int; 2008; 18(3):212-9. PubMed ID: 18924077
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Recall of the ASR XL Head and Hip Resurfacing Systems.
    Maurer-Ertl W; Friesenbichler J; Holzer LA; Leitner L; Ogris K; Maier M; Leithner A
    Orthopedics; 2017 Mar; 40(2):e340-e347. PubMed ID: 27992643
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Metal ion interpretation in resurfacing versus conventional hip arthroplasty and in whole blood versus serum. How should we interpret metal ion data.
    Smolders JM; Bisseling P; Hol A; Van Der Straeten C; Schreurs BW; van Susante JL
    Hip Int; 2011; 21(5):587-95. PubMed ID: 21948034
    [TBL] [Abstract][Full Text] [Related]  

  • 53. The articular surface replacement implant recall: a United Kingdom district hospital experience.
    Whitwell GS; Shine A; Young SK
    Hip Int; 2012; 22(4):362-70. PubMed ID: 22865254
    [TBL] [Abstract][Full Text] [Related]  

  • 54. A Randomized Seven-Year Study on Performance of the Stemmed Metal M2a-Magnum and Ceramic C2a-Taper, and the Resurfacing ReCap Hip Implants.
    Borgwardt A; Borgwardt L; Zerahn B; Daugaard H; Borgwardt L; Ribel-Madsen S
    J Arthroplasty; 2018 May; 33(5):1412-1420. PubMed ID: 29276121
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Metal ion levels in total hip arthroplasty versus hip resurfacing.
    Johnson AJ; Le Duff MJ; Yoon JP; Al-Hamad M; Amstutz HC
    J Arthroplasty; 2013 Aug; 28(7):1235-7. PubMed ID: 23618754
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Metal ion levels and functional results after either resurfacing hip arthroplasty or conventional metal-on-metal hip arthroplasty.
    Smolders JM; Hol A; Rijnberg WJ; van Susante JL
    Acta Orthop; 2011 Oct; 82(5):559-66. PubMed ID: 22103280
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Large fixed-size metal-on-metal total hip arthroplasty: higher serum metal ion levels in patients with pain.
    Smeekes C; Ongkiehong B; van der Wal B; Wolterbeek R; Henseler JF; Nelissen R
    Int Orthop; 2015 Apr; 39(4):631-8. PubMed ID: 25472752
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Does ion release differ between hip resurfacing and metal-on-metal THA?
    Moroni A; Savarino L; Cadossi M; Baldini N; Giannini S
    Clin Orthop Relat Res; 2008 Mar; 466(3):700-7. PubMed ID: 18196364
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Comparing 1-year and 10-year whole blood metal ion results following Birmingham hip resurfacing for osteoarthritis.
    Watt Kearns SJ; Bourget-Murray J; Johnston K; Werle J
    Can J Surg; 2022; 65(4):E504-E511. PubMed ID: 35926884
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Poor Survivorship and Frequent Complications at a Median of 10 Years After Metal-on-Metal Hip Resurfacing Revision.
    Matharu GS; Pandit HG; Murray DW
    Clin Orthop Relat Res; 2017 Feb; 475(2):304-314. PubMed ID: 27188835
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.