BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

418 related articles for article (PubMed ID: 22932750)

  • 1. Comparison of cannulated screw with tension band wiring versus compressive cannulated locking bolt and nut device (CompresSURE) in patella fractures-a cadaveric biomechanical study.
    Domby B; Henderson E; Nayak A; Erdoğan M; Gutierrez S; Santoni BG; Sagi HC
    J Orthop Trauma; 2012 Dec; 26(12):678-83. PubMed ID: 22932750
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures.
    Thelen S; Schneppendahl J; Jopen E; Eichler C; Koebke J; Schönau E; Hakimi M; Windolf J; Wild M
    Injury; 2012 Aug; 43(8):1290-5. PubMed ID: 22608600
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation.
    Zderic I; Stoffel K; Sommer C; Höntzsch D; Gueorguiev B
    Injury; 2017 Aug; 48(8):1749-1757. PubMed ID: 28622833
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical comparison of a 3.5 mm anterior locking plate to cannulated screws with anterior tension band wiring in comminuted patellar fractures.
    Wagner FC; Neumann MV; Wolf S; Jonaszik A; Izadpanah K; Piatek S; Südkamp NP
    Injury; 2020 Jun; 51(6):1281-1287. PubMed ID: 32197829
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of tension band- and interfragmentary screw fixation with a new implant in transverse patella fractures.
    Dargel J; Gick S; Mader K; Koebke J; Pennig D
    Injury; 2010 Feb; 41(2):156-60. PubMed ID: 19665707
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transverse patella fracture fixation: A cadaveric biomechanical comparison of cannulated screws and anterior tension band versus low-profile, multiplanar mesh plating.
    Garner MR; Homcha B; Cowman T; Goss M; Reid JS; Lewis GS
    Injury; 2024 Jun; 55(6):111574. PubMed ID: 38669892
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Cannulated Screw Prominence in Tension Band Wiring of Patella Fractures Increases Fracture Gapping: A Cadaver Study.
    Avery MC; Jo S; Chang A; Ricci WM; McAndrew C; Miller AN; Tang S
    Clin Orthop Relat Res; 2019 May; 477(5):1249-1255. PubMed ID: 30998643
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical comparison of three tension band wiring techniques for transverse fracture of patella: Kirschner wires, cannulated screws, and ring pins.
    Lee KH; Lee Y; Lee YH; Cho BW; Kim MB; Baek GH
    J Orthop Surg (Hong Kong); 2019; 27(3):2309499019882140. PubMed ID: 31711358
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study.
    Warner S; Sommer C; Zderic I; Woodburn W; Castle R; Penman J; Saura-Sanchez E; Helfet DL; Gueorguiev B; Stoffel K
    Arch Orthop Trauma Surg; 2024 May; 144(5):2131-2140. PubMed ID: 38520547
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Locked Intraosseous Nail for Transverse Patellar Fractures: A Biomechanical Comparison with Tension Band Wiring Through Cannulated Screws.
    Nienhaus M; Zderic I; Wahl D; Gueorguiev B; Rommens PM
    J Bone Joint Surg Am; 2018 Jun; 100(12):e83. PubMed ID: 29916933
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the Therapeutic Effects of Tension Band with Cannulated Screw and Tension Band with Kirschner Wire on Patella Fracture.
    Liu C; Ren H; Wan C; Ma J
    Comput Math Methods Med; 2020; 2020():4065978. PubMed ID: 32908578
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures.
    Thelen S; Schneppendahl J; Baumgärtner R; Eichler C; Koebke J; Betsch M; Hakimi M; Windolf J; Wild M
    Knee Surg Sports Traumatol Arthrosc; 2013 Feb; 21(2):311-7. PubMed ID: 22491707
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A double button adjustable loop device is biomechanically equivalent to tension band wire in the fixation of transverse patellar fractures-A cadaveric study.
    Han F; Pearce CJ; Ng DQ; Ramruttun AK; Chong DY; Murphy D; Lim CT; Lee BC
    Injury; 2017 Feb; 48(2):270-276. PubMed ID: 27890337
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Role of screw proximity in the fixation of transverse patellar fractures with screws and a wire.
    Chang CW; Chen YN; Li CT; Chung YH; Chang CH; Peng YT
    J Orthop Surg (Hong Kong); 2018; 26(3):2309499018789705. PubMed ID: 30037293
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical evaluation of current patella fracture fixation techniques.
    Carpenter JE; Kasman RA; Patel N; Lee ML; Goldstein SA
    J Orthop Trauma; 1997 Jul; 11(5):351-6. PubMed ID: 9294799
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fixation of multifragmentary patella fractures using a bilateral fixed-angle plate.
    Thelen S; Betsch M; Schneppendahl J; Grassmann J; Hakimi M; Eichler C; Windolf J; Wild M
    Orthopedics; 2013 Nov; 36(11):e1437-43. PubMed ID: 24200450
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An alternative patellar fracture fixation: a biomechanical study.
    Banks KE; Ambrose CG; Wheeless JS; Tissue CM; Sen M
    J Orthop Trauma; 2013 Jun; 27(6):345-51. PubMed ID: 22773018
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of methods of internal fixation of transverse patella fractures: a biomechanical study.
    Burvant JG; Thomas KA; Alexander R; Harris MB
    J Orthop Trauma; 1994; 8(2):147-53. PubMed ID: 8207572
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A Biomechanical Study of an Alternative Internal Fixation Method for Transverse Patella Fractures.
    Han S; Li D; Zhang P; Yin X; Kou Y; Han N; Fu Z
    Orthopedics; 2018 Sep; 41(5):e643-e648. PubMed ID: 30011055
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires.
    Hoshino CM; Tran W; Tiberi JV; Black MH; Li BH; Gold SM; Navarro RA
    J Bone Joint Surg Am; 2013 Apr; 95(7):653-9. PubMed ID: 23553301
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.