These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
227 related articles for article (PubMed ID: 2294366)
21. Clinical study of blood trauma during perfusion with membrane and bubble oxygenators. van den Dungen JJ; Karliczek GF; Brenken U; Homan van der Heide JN; Wildevuur CR J Thorac Cardiovasc Surg; 1982 Jan; 83(1):108-16. PubMed ID: 7054605 [TBL] [Abstract][Full Text] [Related]
22. Different oxygenators for cardiopulmonary bypass lead to varying degrees of human complement activation in vitro. Videm V; Fosse E; Mollnes TE; Ellingsen O; Pedersen T; Karlsen H J Thorac Cardiovasc Surg; 1989 May; 97(5):764-70. PubMed ID: 2709867 [TBL] [Abstract][Full Text] [Related]
23. Effect of oxygenator type and bypass flow pattern on the P(a-ET)CO2 gradient. Opper SE; Fibuch EE; Nelson RE; Lonergan JH J Cardiothorac Vasc Anesth; 1992 Feb; 6(1):46-50. PubMed ID: 1543853 [TBL] [Abstract][Full Text] [Related]
24. Fate of indium 111-labeled platelets during cardiopulmonary bypass performed with membrane and bubble oxygenators. Peterson KA; Dewanjee MK; Kaye MP J Thorac Cardiovasc Surg; 1982 Jul; 84(1):39-43. PubMed ID: 7087539 [TBL] [Abstract][Full Text] [Related]
25. Quantification of extracorporeal white cell and platelet deposition in cardiopulmonary bypass: comparison of membrane and bubble oxygenators. Martin W; McQuiston AM; Tweddel AC; Wheatley DJ Nucl Med Commun; 1996 May; 17(5):378-84. PubMed ID: 8736513 [TBL] [Abstract][Full Text] [Related]
26. Membrane and bubble oxygenator: a clinical comparison in patients undergoing aortocoronary bypass procedures. Alon L; Turina M; Gattiker R Herz; 1979 Feb; 4(1):56-62. PubMed ID: 108187 [TBL] [Abstract][Full Text] [Related]
27. A comparison of the effects of membrane and bubble oxygenators on platelet counts and platelet size in elective cardiac operations. Trumbull HR; Howe J; Mottl K; Nicoloff DM Ann Thorac Surg; 1980 Jul; 30(1):52-7. PubMed ID: 7396579 [TBL] [Abstract][Full Text] [Related]
28. Respiratory function after cardiopulmonary bypass: a comparison of bubble and membrane oxygenators. Reeve WG; Ingram SM; Smith DC J Cardiothorac Vasc Anesth; 1994 Oct; 8(5):502-8. PubMed ID: 7803737 [TBL] [Abstract][Full Text] [Related]
29. Cardiopulmonary bypass. Microembolization and platelet aggregation. Solis RT; Kennedy PS; Beall AC; Noon GP; DeBakey ME Circulation; 1975 Jul; 52(1):103-8. PubMed ID: 1132112 [TBL] [Abstract][Full Text] [Related]
30. Cerebral protection during open heart surgery. A comparison between a disk oxygenator and two bubble oxygenators. Aberg T; Kihlgren M Thoraxchir Vask Chir; 1977 Jun; 25(3):146-51. PubMed ID: 898163 [TBL] [Abstract][Full Text] [Related]
31. Haematological characteristics of a new membrane oxygenator: the Cobe CML. Harder MP; Leusink JA; de Nooy EH; Gerding A; Wildevuur CR J Cardiovasc Surg (Torino); 1987; 28(6):627-32. PubMed ID: 2959665 [TBL] [Abstract][Full Text] [Related]
32. Oxygenation strategy and neurologic damage after deep hypothermic circulatory arrest. I. Gaseous microemboli. Nollert G; Nagashima M; Bucerius J; Shin'oka T; Jonas RA J Thorac Cardiovasc Surg; 1999 Jun; 117(6):1166-71. PubMed ID: 10343268 [TBL] [Abstract][Full Text] [Related]
34. A clinical evaluation of the gas transfer characteristics and gaseous microemboli production of two bubble oxygenators. Pearson DT; Holden MP; Poslad SJ; Murray A; Waterhouse PS Life Support Syst; 1984; 2(4):252-66. PubMed ID: 6441873 [TBL] [Abstract][Full Text] [Related]
35. [A new approach for studying the retinal and choroidal circulation]. Yoneya S Nippon Ganka Gakkai Zasshi; 2004 Dec; 108(12):836-61; discussion 862. PubMed ID: 15656089 [TBL] [Abstract][Full Text] [Related]
36. [Left ventricular decompression and neuropsychiatric disorders in coronary surgery]. Bezon E; Couzot T; Mahlab A; Barra JA; Lacroix J Ann Chir; 1993; 47(8):696-701. PubMed ID: 8311399 [TBL] [Abstract][Full Text] [Related]
37. Evaluation of neonatal membrane oxygenators with respect to gaseous microemboli capture and transmembrane pressure gradients. Qiu F; Guan Y; Su X; Kunselman A; Undar A Artif Organs; 2010 Nov; 34(11):923-9. PubMed ID: 21092035 [TBL] [Abstract][Full Text] [Related]
38. Limitations using the vacuum-assist venous drainage technique during cardiopulmonary bypass procedures. Jegger D; Tevaearai HT; Mueller XM; Horisberger J; von Segesser LK J Extra Corpor Technol; 2003 Sep; 35(3):207-11. PubMed ID: 14653422 [TBL] [Abstract][Full Text] [Related]
39. Improved biocompatibility of extracorporeal circulation by the use of auto-oxygenation instead of artificial oxygenator in perfusion circuit. Bochenek A; Religa Z; Kustosz R; Wnuk-Wojnar AM; Wnuk R; Wojnar J; Woś S; Wites M; Zembala M; Spyt T Nephrol Dial Transplant; 1991; 6 Suppl 3():75-80. PubMed ID: 1775272 [TBL] [Abstract][Full Text] [Related]
40. Similarity of clinical and laboratory results obtained with microporous teflon membrane oxygenator and bubble-film hybrid oxygenator. Williams DR; Tyers GF; Williams EH; Kurusz M; Shaffer CW; Pierce WS; Waldhausen JA Ann Thorac Surg; 1978 Jan; 25(1):30-5. PubMed ID: 619809 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]