253 related articles for article (PubMed ID: 22947504)
1. Direct glutathione quantification in human blood by LC-MS/MS: comparison with HPLC with electrochemical detection.
Squellerio I; Caruso D; Porro B; Veglia F; Tremoli E; Cavalca V
J Pharm Biomed Anal; 2012 Dec; 71():111-8. PubMed ID: 22947504
[TBL] [Abstract][Full Text] [Related]
2. A new LC-MS/MS method for the clinical determination of reduced and oxidized glutathione from whole blood.
Moore T; Le A; Niemi AK; Kwan T; Cusmano-Ozog K; Enns GM; Cowan TM
J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Jun; 929():51-5. PubMed ID: 23660247
[TBL] [Abstract][Full Text] [Related]
3. Validation of a liquid chromatography tandem mass spectrometry method to measure oxidized and reduced forms of glutathione in whole blood and verification in a mouse model as an indicator of oxidative stress.
Lee SG; Yim J; Lim Y; Kim JH
J Chromatogr B Analyt Technol Biomed Life Sci; 2016 Apr; 1019():45-50. PubMed ID: 26575459
[TBL] [Abstract][Full Text] [Related]
4. Validation of high-performance liquid chromatography-boron-doped diamond detection for assessing hepatic glutathione redox status.
Park HJ; Mah E; Bruno RS
Anal Biochem; 2010 Dec; 407(2):151-9. PubMed ID: 20705049
[TBL] [Abstract][Full Text] [Related]
5. Molecular speciated isotope dilution mass spectrometric methods for accurate, reproducible and direct quantification of reduced, oxidized and total glutathione in biological samples.
Fahrenholz T; Wolle MM; Kingston HM; Faber S; Kern JC; Pamuku M; Miller L; Chatragadda H; Kogelnik A
Anal Chem; 2015 Jan; 87(2):1232-40. PubMed ID: 25519489
[TBL] [Abstract][Full Text] [Related]
6. Validation of a simplified procedure for convenient and rapid quantification of reduced and oxidized glutathione in human plasma by liquid chromatography tandem mass spectrometry analysis.
Enomoto AC; Schneider E; McKinnon T; Goldfine H; Levy MA
Biomed Chromatogr; 2020 Sep; 34(9):e4854. PubMed ID: 32302415
[TBL] [Abstract][Full Text] [Related]
7. High-throughput liquid chromatography differential mobility spectrometry mass spectrometry for bioanalysis: determination of reduced and oxidized form of glutathione in human blood.
Bravo-Veyrat S; Hopfgartner G
Anal Bioanal Chem; 2018 Nov; 410(27):7153-7161. PubMed ID: 30151684
[TBL] [Abstract][Full Text] [Related]
8. Validated high-performance liquid chromatography-electrochemical method for determination of glutathione and glutathione disulfide in small tissue samples.
Lakritz J; Plopper CG; Buckpitt AR
Anal Biochem; 1997 Apr; 247(1):63-8. PubMed ID: 9126372
[TBL] [Abstract][Full Text] [Related]
9. Simultaneous determination of reduced glutathione, glutathione disulphide and glutathione sulphonamide in cells and physiological fluids by isotope dilution liquid chromatography-tandem mass spectrometry.
Harwood DT; Kettle AJ; Brennan S; Winterbourn CC
J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Oct; 877(28):3393-9. PubMed ID: 19414284
[TBL] [Abstract][Full Text] [Related]
10. A stable-isotope HPLC-MS/MS method to simplify storage of human whole blood samples for glutathione assay.
Norris RL; Paul M; George R; Moore A; Pinkerton R; Haywood A; Charles B
J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Jun; 898():136-40. PubMed ID: 22608807
[TBL] [Abstract][Full Text] [Related]
11. Analysis and quantification of vitamin D metabolites in serum by ultra-performance liquid chromatography coupled to tandem mass spectrometry and high-resolution mass spectrometry--a method comparison and validation.
Bruce SJ; Rochat B; Béguin A; Pesse B; Guessous I; Boulat O; Henry H
Rapid Commun Mass Spectrom; 2013 Jan; 27(1):200-6. PubMed ID: 23239334
[TBL] [Abstract][Full Text] [Related]
12. Determination of cellular redox status by stable isotope dilution liquid chromatography/mass spectrometry analysis of glutathione and glutathione disulfide.
Zhu P; Oe T; Blair IA
Rapid Commun Mass Spectrom; 2008; 22(4):432-40. PubMed ID: 18215009
[TBL] [Abstract][Full Text] [Related]
13. LC-MS determination of oxidized and reduced glutathione in human dermis: a microdialysis study.
Robin S; Leveque N; Courderot-Masuyer C; Humbert P
J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Nov; 879(30):3599-606. PubMed ID: 22019294
[TBL] [Abstract][Full Text] [Related]
14. Determination of reduced and oxidized glutathione in biological samples using liquid chromatography with fluorimetric detection.
Kand'ár R; Záková P; Lotková H; Kucera O; Cervinková Z
J Pharm Biomed Anal; 2007 Mar; 43(4):1382-7. PubMed ID: 17182211
[TBL] [Abstract][Full Text] [Related]
15. A standardized protocol for comparable analysis of GSH/GSSG by UHPLC-ESI-MSMS for human plasma.
Claeson AS; Gouveia-Figueira S; Stenlund H; Johansson AI
J Chromatogr B Analyt Technol Biomed Life Sci; 2019 Jan; 1104():67-72. PubMed ID: 30445289
[TBL] [Abstract][Full Text] [Related]
16. A sensitive method for the analysis of glutathione in porcine hepatocytes.
Florholmen-Kjær Å; Lyså RA; Fuskevåg OM; Goll R; Revhaug A; Mortensen KE
Scand J Gastroenterol; 2014 Nov; 49(11):1359-66. PubMed ID: 25279941
[TBL] [Abstract][Full Text] [Related]
17. Simultaneous determination of sulphur metabolites in Arabidopsis thaliana via LC-ESI-MS/MS and ³⁴S-metabolic labelling.
Hsieh CL; Yeh KW; De Kok LJ; Pan RN; Kuo YH; Tseng MH
Phytochem Anal; 2012; 23(4):324-31. PubMed ID: 21987403
[TBL] [Abstract][Full Text] [Related]
18. Development of a reliable method based on ultra-performance liquid chromatography coupled to tandem mass spectrometry to measure thiol-associated oxidative stress in whole blood samples.
Escobar J; Sánchez-Illana Á; Kuligowski J; Torres-Cuevas I; Solberg R; Garberg HT; Huun MU; Saugstad OD; Vento M; Cháfer-Pericás C
J Pharm Biomed Anal; 2016 May; 123():104-12. PubMed ID: 26895495
[TBL] [Abstract][Full Text] [Related]
19. Liquid chromatography-tandem mass spectrometry assay of reduced and oxidized glutathione and main precursors in mice liver.
Bouligand J; Deroussent A; Paci A; Morizet J; Vassal G
J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Feb; 832(1):67-74. PubMed ID: 16434243
[TBL] [Abstract][Full Text] [Related]
20. Determination of glutathione and glutathione disulfide in hepatocytes by liquid chromatography with an electrode modified with functionalized carbon nanotubes.
Zhang W; Wan F; Zhu W; Xu H; Ye X; Cheng R; Jin LT
J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Apr; 818(2):227-32. PubMed ID: 15734163
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]