BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

243 related articles for article (PubMed ID: 22947628)

  • 21. Idiopathic ventricular arrhythmias detected by an implantable loop recorder in a child with exercise-induced syncope.
    Akdeniz C; Ozyilmaz I; Saygi M; Ergul Y; Tuzcu V
    Tex Heart Inst J; 2013; 40(3):347-9. PubMed ID: 23914037
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Diagnostic assessment of recurrent unexplained syncope with a new subcutaneously implantable loop recorder. Reveal-Investigators.
    Seidl K; Rameken M; Breunung S; Senges J; Jung W; Andresen D; van Toor A; Krahn AD; Klein GJ;
    Europace; 2000 Jul; 2(3):256-62. PubMed ID: 11227598
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Diagnostic benefit of the use of implanted loop recorder (Reveal Plus) for patients with syncope with unclear aetiology].
    Mitro P; Szakács M; Bodnár J; Valocik G; Kirsch P; Mudráková K
    Vnitr Lek; 2007 Nov; 53(11):1147-52. PubMed ID: 18277623
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Clinical utility of a novel wireless implantable loop recorder in the evaluation of patients with unexplained syncope.
    Paruchuri V; Adhaduk M; Garikipati NV; Steinberg JS; Mittal S
    Heart Rhythm; 2011 Jun; 8(6):858-63. PubMed ID: 21296683
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Insertable loop recorder in unmasking the cause of syncope.
    Simantirakis EN; Chrysostomakis SI; Manios EG; Vardas PE
    Pacing Clin Electrophysiol; 2000 Oct; 23(10 Pt 1):1573-5. PubMed ID: 11060883
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The use of an implantable loop recorder in the investigation of unexplained syncope in older people.
    Armstrong VL; Lawson J; Kamper AM; Newton J; Kenny RA
    Age Ageing; 2003 Mar; 32(2):185-8. PubMed ID: 12615562
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Use of an implantable loop recorder to investigate syncope in a cat.
    Willis R; McLeod K; Cusack J; Wotton P
    J Small Anim Pract; 2003 Apr; 44(4):181-3. PubMed ID: 12703871
    [TBL] [Abstract][Full Text] [Related]  

  • 28. External prolonged electrocardiogram monitoring in unexplained syncope and palpitations: results of the SYNARR-Flash study.
    Locati ET; Moya A; Oliveira M; Tanner H; Willems R; Lunati M; Brignole M
    Europace; 2016 Aug; 18(8):1265-72. PubMed ID: 26519025
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Clinical usefulness of implantable loop recorder in diagnosis of unexplained syncope--case report].
    Stec S; Makowska E; Kułakowski P
    Kardiol Pol; 2005 Apr; 62(4):376-80; discussion 380. PubMed ID: 15928742
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Insertable loop recorder use for detection of intermittent arrhythmias.
    Krahn AD; Klein GJ; Skanes AC; Yee R
    Pacing Clin Electrophysiol; 2004 May; 27(5):657-64. PubMed ID: 15125724
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Usefulness of an Implantable Loop Recorder in Diagnosing Unexplained Syncope and Predictors for Pacemaker Implantation.
    Lee SH; Kim TH; Oh YS; Oh S; Choi JI; Kim JB; Nah JC; Im SI; Kang KW; Han S; Kim JS
    J Korean Med Sci; 2020 Jan; 35(2):e11. PubMed ID: 31920017
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Initial clinical experience with implantable loop recorders.
    Mieszczanska H; Ibrahim B; Cohen TJ
    J Invasive Cardiol; 2001 Dec; 13(12):802-4. PubMed ID: 11731693
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The benefit of a remotely monitored implantable loop recorder as a first line investigation in unexplained syncope: the EaSyAS II trial.
    Sulke N; Sugihara C; Hong P; Patel N; Freemantle N
    Europace; 2016 Jun; 18(6):912-8. PubMed ID: 26462702
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Clinical implications of long-term ECG monitoring: from loop recorder to devices remote control.
    DI Cori A; DE Lucia R
    Minerva Cardioangiol; 2018 Feb; 66(1):40-48. PubMed ID: 28718277
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Use of the implantable loop recorder in children and adolescents.
    Gass M; Apitz C; Salehi-Gilani S; Ziemer G; Hofbeck M
    Cardiol Young; 2006 Dec; 16(6):572-8. PubMed ID: 17116271
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Experience with the use of an implantable loop recorder in a series of older people with falls and suspected arrhythmic syncopes].
    Martínez P; Pilar Sáez M; Rubio JA; Cánovas E; Esteban E; Botas J
    Rev Esp Geriatr Gerontol; 2014; 49(3):121-4. PubMed ID: 24548525
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Generalized tonic-clonic seizures detected by implantable loop recorder devices: diagnosing more than cardiac arrhythmias.
    Ho RT; Wicks T; Wyeth D; Nei M
    Heart Rhythm; 2006 Jul; 3(7):857-61. PubMed ID: 16818222
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Long-term cardiac monitoring in older adults with unexplained falls and syncope.
    Bhangu J; McMahon CG; Hall P; Bennett K; Rice C; Crean P; Sutton R; Kenny RA
    Heart; 2016 May; 102(9):681-6. PubMed ID: 26822427
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Usefulness of echocardiography for predicting ventricular tachycardia detected by implantable loop recorder in syncope patients.
    Falsing MM; Brainin P; Andersen DM; Larroudé CE; Lindhardt TB; Modin D; Ravnkilde K; Karsum EH; Gislason G; Biering-Sørensen T
    Int J Cardiovasc Imaging; 2021 Nov; 37(11):3157-3166. PubMed ID: 34050421
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Cardiac loop ECG recording: a new noninvasive diagnostic test in recurrent syncope.
    Cumbee SR; Pryor RE; Linzer M
    South Med J; 1990 Jan; 83(1):39-43. PubMed ID: 2300833
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.