BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 2295160)

  • 41. A long-term follow-up study of total hip replacement with bone graft. Correlations between roentgenographic measurement and hip mobility.
    Matsuno T; Masuda T; Hasegawa I; Kanno T; Ichioka Y; Matsuno S; Hirai K
    Arch Orthop Trauma Surg; 1989; 108(1):14-21. PubMed ID: 2643937
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Bipolar socket in protrusio acetabuli. 3-6-year study.
    Wilson MG; Scott RD
    J Arthroplasty; 1993 Aug; 8(4):405-11. PubMed ID: 8409993
    [TBL] [Abstract][Full Text] [Related]  

  • 43. [Homologous bone transplantation in acetabular bone defects in the loosening of the prosthesis].
    Tjernström B; Olerud S
    Lakartidningen; 1987 Oct; 84(44):3586-8. PubMed ID: 3320634
    [No Abstract]   [Full Text] [Related]  

  • 44. Lateral acetabular bone graft in total hip arthroplasty. A three- to eight-year follow-up study without internal fixation.
    Ritter MA; Trancik TM
    Clin Orthop Relat Res; 1985 Mar; (193):156-9. PubMed ID: 3882292
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Roentgenographic evaluation of a conical threaded acetabular cup.
    Keating EM; Czarkowski RA; Ritter MA; Faris PM
    Semin Arthroplasty; 1990 Jul; 1(1):45-9. PubMed ID: 10149556
    [TBL] [Abstract][Full Text] [Related]  

  • 46. The Bateman bipolar prosthesis in osteoarthritis and rheumatoid arthritis. A review of 400 cases.
    Vázquez-Vela G; Vázquez-Vela E; Garcia Dobarganes F
    Clin Orthop Relat Res; 1990 Feb; (251):82-6. PubMed ID: 2295200
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Long-term results of bipolar arthroplasty in osteoarthritis of the hip.
    Bateman JE; Berenji AR; Bayne O; Greyson ND
    Clin Orthop Relat Res; 1990 Feb; (251):54-66. PubMed ID: 2295197
    [TBL] [Abstract][Full Text] [Related]  

  • 48. The screwed acetabulum in acetabular reimplantations: long-term results.
    Gusso MI; Acanfora A; Civinini R; Cristiano R
    Chir Organi Mov; 1994; 79(4):397-403. PubMed ID: 7614881
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Cementless acetabular replacement using a pegged polyethylene prosthesis.
    Bertin KC; Freeman MA; Morscher E; Oeri A; Ring PA
    Arch Orthop Trauma Surg (1978); 1985; 104(4):251-61. PubMed ID: 3936457
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Comparison of radiographic parameters for analysis of normal and dysplastic hips in the adult.
    Goodman SB
    Contemp Orthop; 1990 May; 20(5):505-11. PubMed ID: 10148037
    [TBL] [Abstract][Full Text] [Related]  

  • 51. [Reconstruction of acetabular insufficiency in initial total hip endoprosthesis surgery using a massive autograft (fate of the implanted autograft more than one year after surgery)].
    Judet T; de Thomasson E; Paukovic J; Arnault O
    Acta Chir Orthop Traumatol Cech; 1994; 61(1):29-33. PubMed ID: 8178606
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Revision of failed hip surface replacement arthroplasties with a bipolar prosthesis. Three case reports with two- to three-year follow-up observations.
    McClelland SJ; Godfrey JD; Benton PC; Slemmons BK
    Clin Orthop Relat Res; 1986 Jul; (208):243-8. PubMed ID: 3720130
    [TBL] [Abstract][Full Text] [Related]  

  • 53. [Analysis of the scintigraphic image of bone grafts in reconstruction of total hip prostheses].
    de la Caffinière JY; Postel JM
    Rev Chir Orthop Reparatrice Appar Mot; 1985; 71(6):369-76. PubMed ID: 3909253
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Bone incorporation of frozen femoral head allograft in revision total hip replacement.
    Kondo K; Nagaya I
    Nihon Seikeigeka Gakkai Zasshi; 1993 May; 67(5):408-16. PubMed ID: 8336061
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Five-year results of bipolar arthroplasty with bone grafts and reamed acetabula for osteoarthritis in young adults.
    Yamamuro T; Ueo T; Okumura H; Iida H; Hamamoto T
    Clin Orthop Relat Res; 1990 Feb; (251):75-81. PubMed ID: 2295199
    [TBL] [Abstract][Full Text] [Related]  

  • 56. [Observation of prosthesis movement after implantation of the bipolar artificial femoral head].
    Sun YH
    Zhonghua Wai Ke Za Zhi; 1992 Oct; 30(10):581-4, 635. PubMed ID: 1306787
    [TBL] [Abstract][Full Text] [Related]  

  • 57. A 15-year follow-up study of 512 consecutive Charnley-Muller total hip replacements.
    Pavlov PW
    J Arthroplasty; 1987; 2(2):151-6. PubMed ID: 3612141
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Metallosis associated with a stable titanium-alloy femoral component in total hip replacement. A case report.
    Black J; Sherk H; Bonini J; Rostoker WR; Schajowicz F; Galante JO
    J Bone Joint Surg Am; 1990 Jan; 72(1):126-30. PubMed ID: 2295661
    [No Abstract]   [Full Text] [Related]  

  • 59. Bipolar femoral head arthroplasty in osteoarthritis. A prospective study with a minimum 5-year follow-up period.
    Pandit R
    J Arthroplasty; 1996 Aug; 11(5):560-4. PubMed ID: 8872576
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Revision of the problem acetabulum with a "big head" bipolar prosthesis.
    Cameron HU; Jung YB
    Acta Orthop Belg; 1987; 53(4):467-71. PubMed ID: 3434247
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.