These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 22955724)

  • 1. Home point-of-care international normalised ratio monitoring sustained by a non-selective educational program in children.
    Bajolle F; Lasne D; Elie C; Cheurfi R; Grazioli A; Traore M; Souillard P; Boudjemline Y; Jourdain P; Bonnet D
    Thromb Haemost; 2012 Oct; 108(4):710-8. PubMed ID: 22955724
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The economic costs of routine INR monitoring in infants and children--examining point-of-care devices used within the home setting compared to traditional anticoagulation clinic monitoring.
    Gaw JR; Crowley S; Monagle P; Jones S; Newall F
    Thromb Res; 2013 Jul; 132(1):26-31. PubMed ID: 23746471
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparative study of anticoagulant control in patients on long-term warfarin using home and hospital monitoring of the international normalised ratio.
    Bradbury MJ; Taylor G; Short P; Williams MD
    Arch Dis Child; 2008 Apr; 93(4):303-6. PubMed ID: 17675359
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Approaches to optimal dosing of vitamin K antagonists.
    Witt DM
    Semin Thromb Hemost; 2012 Oct; 38(7):667-72. PubMed ID: 22893509
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Point-of-care monitoring of oral anticoagulation therapy in children. Comparison of the CoaguChek XS system with venous INR and venous INR using an International Reference Thromboplastin preparation (rTF/95).
    Greenway A; Ignjatovic V; Summerhayes R; Newall F; Burgess J; DeRosa L; Monagle P
    Thromb Haemost; 2009 Jul; 102(1):159-65. PubMed ID: 19572081
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of a portable international normalized ratio monitor for patients receiving a low molecular weight heparin as a bridge pending full oral anticoagulant efficacy.
    Meurin P; Tabet JY; Monchi M; Weber H; Fabre C; Gibier B; Renaud N; Driss AB
    Thromb Res; 2010 Feb; 125(2):192-5. PubMed ID: 19942256
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quality of life in children participating in a non-selective INR self-monitoring VKA-education programme.
    Amedro P; Bajolle F; Bertet H; Cheurfi R; Lasne D; Nogue E; Auquier P; Picot MC; Bonnet D
    Arch Cardiovasc Dis; 2018 Mar; 111(3):180-188. PubMed ID: 29100908
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Improving the management of warfarin in aged-care facilities utilising innovative technology: a proof-of-concept study.
    Bereznicki LR; Jackson SL; Kromdijk W; Gee P; Fitzmaurice K; Bereznicki BJ; Peterson GM
    Int J Pharm Pract; 2014 Feb; 22(1):84-91. PubMed ID: 23581399
    [TBL] [Abstract][Full Text] [Related]  

  • 9. KIDCLOT: the importance of validated educational intervention for optimal long term warfarin management in children.
    Bauman ME; Black K; Kuhle S; Wang L; Legge L; Callen-Wicks D; Mitchell L; Bajzar L; Massicotte MP;
    Thromb Res; 2009 Mar; 123(5):707-9. PubMed ID: 18786700
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Feasibility, cost-effectiveness and patients' acceptance of point-of-care INR testing in a hospital-based anticoagulation clinic.
    Kong MC; Lim TG; Ng HJ; Chan YH; Lee LH
    Ann Hematol; 2008 Nov; 87(11):905-10. PubMed ID: 18604535
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of the CoaguChek XS for point-of-care international normalized ratio (INR) measurement in children requiring warfarin.
    Bauman ME; Black KL; Massicotte MP; Bauman ML; Kuhle S; Howlett-Clyne S; Cembrowski GS; Bajzar L
    Thromb Haemost; 2008 Jun; 99(6):1097-103. PubMed ID: 18521514
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Safety and efficacy of warfarin in paediatric patients with prosthetic cardiac valves: a retrospective audit.
    Wong CS; Batchelor K; Bua J; Newall F
    Thromb Res; 2011 Oct; 128(4):331-4. PubMed ID: 21620442
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In-patient international normalized ratio self-testing instruction after mechanical heart valve implantation.
    Thompson JL; Sundt TM; Sarano ME; Santrach PJ; Schaff HV
    Ann Thorac Surg; 2008 Jun; 85(6):2046-50. PubMed ID: 18498817
    [TBL] [Abstract][Full Text] [Related]  

  • 14. International normalized ratio monitoring of vitamin K antagonist therapy: comparative performance of point-of-care and laboratory-derived testing.
    Bonar R; Mohammed S; Favaloro EJ
    Semin Thromb Hemost; 2015 Apr; 41(3):279-86. PubMed ID: 25839866
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quality of life assessment in children commencing home INR self-testing.
    Jones S; Monagle P; Manias E; Bruce AA; Newall F
    Thromb Res; 2013 Jul; 132(1):37-43. PubMed ID: 23726963
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of point-of-care international normalized ratio monitoring on quality of treatment with vitamin K antagonists in non-self-monitoring patients: a cohort study.
    Biedermann JS; van Rein N; van den Besselaar AM; Buhre PN; de Maat MP; van der Meer FJ; Leebeek FW; Kruip MJ
    J Thromb Haemost; 2016 Apr; 14(4):695-703. PubMed ID: 26806724
    [TBL] [Abstract][Full Text] [Related]  

  • 17. iPod™ technology for teaching patients about anticoagulation: a pilot study of mobile computer-assisted patient education.
    Denizard-Thompson NR; Singh S; Stevens SR; Miller DP; Wofford JL
    Prim Health Care Res Dev; 2012 Jan; 13(1):42-7. PubMed ID: 21854695
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Vitamin K antagonist overdose induced blindness in an infant: an argument for a therapeutic educational program].
    Bui Quoc E; Bonnet D; Bajolle F
    Arch Pediatr; 2012 Jan; 19(1):22-6. PubMed ID: 22169573
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Point-of-care monitoring of vitamin K-antagonists: validation of CoaguChek XS test strips with International Standard thromboplastin.
    van den Besselaar AM; Péquériaux NC; Ebben M; van der Feest J; de Jong K; Ganzeboom MB; van Ooijen J; Postema F; Witteveen E; van der Meer FJ
    J Clin Pathol; 2012 Nov; 65(11):1031-5. PubMed ID: 22859395
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The clinical significance of differences between point-of-care and laboratory INR methods in over-anticoagulated patients.
    Lawrie AS; Hills J; Longair I; Green L; Gardiner C; Machin SJ; Cohen H
    Thromb Res; 2012 Jul; 130(1):110-4. PubMed ID: 21937093
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.