313 related articles for article (PubMed ID: 22955870)
1. On the effect of body capacitance to ground in tetrapolar bioimpedance measurements.
Aliau-Bonet C; Pallas-Areny R
IEEE Trans Biomed Eng; 2012 Dec; 59(12):3405-11. PubMed ID: 22955870
[TBL] [Abstract][Full Text] [Related]
2. Body composition modeling in the calf using an equivalent circuit model of multi-frequency bioimpedance analysis.
Zhu F; Leonard EF; Levin NW
Physiol Meas; 2005 Apr; 26(2):S133-43. PubMed ID: 15798226
[TBL] [Abstract][Full Text] [Related]
3. An instrumentation amplifier as a front-end for a four-electrode bioimpedance measurement.
Zagar T; Krizaj D
Physiol Meas; 2007 Aug; 28(8):N57-65. PubMed ID: 17664668
[TBL] [Abstract][Full Text] [Related]
4. A model of artefacts produced by stray capacitance during whole body or segmental bioimpedance spectroscopy.
Scharfetter H; Hartinger P; Hinghofer-Szalkay H; Hutten H
Physiol Meas; 1998 May; 19(2):247-61. PubMed ID: 9626689
[TBL] [Abstract][Full Text] [Related]
5. Effects of stray capacitance to ground in three electrode monopolar needle bioimpedance measurements.
Kalvoy H; Aliau-Bonet C; Pallas-Areny R; Martinsen OG
Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():7542-5. PubMed ID: 26738037
[TBL] [Abstract][Full Text] [Related]
6. Electrical impedance myography at frequencies up to 2 MHz.
Shiffman CA; Kashuri H; Aaron R
Physiol Meas; 2008 Jun; 29(6):S345-63. PubMed ID: 18544820
[TBL] [Abstract][Full Text] [Related]
7. Experimental determination of Cm measurement related hardware parameters of the patch-clamp amplifier.
Zhang H; Xiong J; Luo J; Qu A
J Neurosci Methods; 2009 Jan; 176(2):246-53. PubMed ID: 18789969
[TBL] [Abstract][Full Text] [Related]
8. Characterization and Correction of Low Frequency Artifacts in Segmental Bioimpedance Measurements.
Scagliusi SF; Delano M
Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-5. PubMed ID: 38082581
[TBL] [Abstract][Full Text] [Related]
9. A Two-Wired Ultra-High Input Impedance Active Electrode.
Guerrero FN; Spinelli EM
IEEE Trans Biomed Circuits Syst; 2018 Apr; 12(2):437-445. PubMed ID: 29570069
[TBL] [Abstract][Full Text] [Related]
10. Reduction of electrode polarization capacitance in low-frequency impedance spectroscopy by using mesh electrodes.
Padmaraj D; Miller JH; Wosik J; Zagozdzon-Wosik W
Biosens Bioelectron; 2011 Nov; 29(1):13-7. PubMed ID: 21872464
[TBL] [Abstract][Full Text] [Related]
11. Measurement errors in multifrequency bioelectrical impedance analyzers with and without impedance electrode mismatch.
Bogónez-Franco P; Nescolarde L; Bragós R; Rosell-Ferrer J; Yandiola I
Physiol Meas; 2009 Jul; 30(7):573-87. PubMed ID: 19491458
[TBL] [Abstract][Full Text] [Related]
12. Influence of electrode impedance changes on the common-mode rejection ratio in bioimpedance measurements.
Petrova GI
Physiol Meas; 1999 Nov; 20(4):N11-9. PubMed ID: 10593234
[TBL] [Abstract][Full Text] [Related]
13. Derivation of Bioimpedance Model Data Utilizing a Compact Analyzer and Two Capacitive Electrodes: A Forearm Example.
Ojarand J; Priidel E; Min M
IEEE Trans Biomed Circuits Syst; 2022 Oct; 16(5):891-901. PubMed ID: 36103451
[TBL] [Abstract][Full Text] [Related]
14. A review of errors in multi-frequency EIT instrumentation.
McEwan A; Cusick G; Holder DS
Physiol Meas; 2007 Jul; 28(7):S197-215. PubMed ID: 17664636
[TBL] [Abstract][Full Text] [Related]
15. New equivalent-electrical circuit model and a practical measurement method for human body impedance.
Chinen K; Kinjo I; Zamami A; Irei K; Nagayama K
Biomed Mater Eng; 2015; 26 Suppl 1():S779-86. PubMed ID: 26406074
[TBL] [Abstract][Full Text] [Related]
16. Non-contact electrocardiogram measuring method based on capacitance coupling electrodes with ultra-high input impedance.
Li J; Wang Y; Li C; Xu Z; Zhao Z; Raza SA; Wang Y
Rev Sci Instrum; 2022 Mar; 93(3):034101. PubMed ID: 35365001
[TBL] [Abstract][Full Text] [Related]
17. Impedance spectroscopy of changes in skin-electrode impedance induced by motion.
Cömert A; Hyttinen J
Biomed Eng Online; 2014 Nov; 13():149. PubMed ID: 25404355
[TBL] [Abstract][Full Text] [Related]
18. Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods.
Jaffrin MY; Morel H
Med Eng Phys; 2008 Dec; 30(10):1257-69. PubMed ID: 18676172
[TBL] [Abstract][Full Text] [Related]
19. Assessment of human body impedance for safety requirements against contact currents for frequencies up to 110 MHz.
De Santis V; Beeckman PA; Lampasi DA; Feliziani M
IEEE Trans Biomed Eng; 2011 Feb; 58(2):390-6. PubMed ID: 20709636
[TBL] [Abstract][Full Text] [Related]
20. Measurement of corneal endothelial impedance with non-invasive external electrodes--a theoretical study.
Mandel Y; Laufer S; Rubinsky B
Med Eng Phys; 2012 Mar; 34(2):195-201. PubMed ID: 21835678
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]