These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 22959843)

  • 1. Accidental, unintentional reprogramming of a temporary external pacemaker leading to R-on-T and cardiac arrest.
    Schulman PM; Merkel MJ; Rozner MA
    J Cardiothorac Vasc Anesth; 2013 Oct; 27(5):944-8. PubMed ID: 22959843
    [No Abstract]   [Full Text] [Related]  

  • 2. R-on-T and cardiac arrest from dual-chamber pacing without an atrial lead.
    Schulman PM; Stecker EC; Rozner MA
    Heart Rhythm; 2012 Jun; 9(6):970-3. PubMed ID: 22300663
    [No Abstract]   [Full Text] [Related]  

  • 3. Cardiac arrest caused by undersensing of a temporary epicardial pacemaker.
    Chemello D; Subramanian A; Kumaraswamy N
    Can J Cardiol; 2010 Jan; 26(1):e13-4. PubMed ID: 20101359
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Malignant ventricular tachycardia and cardiac arrest induced by a micra™ leadless pacemaker.
    Olsen FJ; Højlund S; Jacobsen MD
    J Electrocardiol; 2018; 51(6):1053-1054. PubMed ID: 30497729
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Accidental insertion of a temporary pacemaker electrode in the left ventricle: radiological and electrocardiographic diagnosis].
    Rickenbacher P; Stettler R; Osswald S
    Schweiz Med Wochenschr; 1996 Oct; 126(40):1688-92. PubMed ID: 8966502
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Asystole caused by vegetation and abscess of right ventricle attached to a tip of pacemaker lead.
    Yamaoka M; Noda T; Nagasawa H; Naganuma M; Otsubo R; Okamura H; Ishibashi-Ueda H; Kamakura S
    Pacing Clin Electrophysiol; 2008 Aug; 31(8):1083-4. PubMed ID: 18684271
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pacemaker-induced arrhythmias.
    Chung EK
    Cardiovasc Clin; 1974; 6(1):199-208. PubMed ID: 4611613
    [No Abstract]   [Full Text] [Related]  

  • 8. An alternate form of endless loop arrhythmia: what are the mechanism and potential solutions?
    Latchamsetty R; Chugh A; Morady F; Jongnarangsin K
    J Cardiovasc Electrophysiol; 2011 Mar; 22(3):352-3. PubMed ID: 20812927
    [No Abstract]   [Full Text] [Related]  

  • 9. Under-sensing by a temporary pacemaker after cardiac surgery and ventricular fibrillation.
    Theodoropoulos KC; Liakopoulou A; Tsagkaropoulos S; Kassimis G; Antonitsis P; Anastasiadis K
    Lancet; 2022 Feb; 399(10325):677. PubMed ID: 35151398
    [No Abstract]   [Full Text] [Related]  

  • 10. A fatal device-device interaction between a wearable automated defibrillator and a unipolar ventricular pacemaker.
    LaPage MJ; Canter CE; Rhee EK
    Pacing Clin Electrophysiol; 2008 Jul; 31(7):912-5. PubMed ID: 18684292
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cardiac arrest: it's all in the head.
    Dinan A; de Toffol B; Pallix M; Breard G; Babuty D
    Lancet; 2008 Apr; 371(9622):1476. PubMed ID: 18440430
    [No Abstract]   [Full Text] [Related]  

  • 12. [Auricular paralysis].
    Bensaid J
    Ann Cardiol Angeiol (Paris); 1975; 24(6):509-17. PubMed ID: 1211826
    [No Abstract]   [Full Text] [Related]  

  • 13. Cardiac arrest from the use of diathermy during total hip arthroplasty in a patient with an external pacemaker.
    Andrade AJ; Grover ML
    Ann R Coll Surg Engl; 1997 Jan; 79(1):69-70. PubMed ID: 9038499
    [No Abstract]   [Full Text] [Related]  

  • 14. Sudden falls due to seizure-induced cardiac asystole in drug-resistant focal epilepsy.
    Rubboli G; Bisulli F; Michelucci R; Meletti S; Ribani MA; Cortelli P; Naldi I; Riguzzi P; Tassinari CA; Tinuper P
    Neurology; 2008 May; 70(20):1933-5. PubMed ID: 18256369
    [No Abstract]   [Full Text] [Related]  

  • 15. Markedly prolonged atrioventricular block with ventricular asystole during sleep.
    Korantzopoulos P; Grekas G; Sioros L; Goudevenos JA
    South Med J; 2009 Aug; 102(8):872-3. PubMed ID: 19593280
    [No Abstract]   [Full Text] [Related]  

  • 16. An unusual cause of asystole during a routine pacemaker generator change.
    Can I; Tholakanahalli V; Li JM
    Pacing Clin Electrophysiol; 2009 Jul; 32(7):949-51. PubMed ID: 19572876
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Dependability of stimulators. Apropos of 2 fatal accidents].
    Gauthier M; Hussonnois JL
    Cah Anesthesiol; 1972; 20(4):451-5. PubMed ID: 5079426
    [No Abstract]   [Full Text] [Related]  

  • 18. [Cardiac arrest secondary to pacemaker dysfunction during general anesthesia in a young adult patient].
    Gayot J; Saint-Pol AL; Degryse C; Sztark F
    Ann Fr Anesth Reanim; 2014 Apr; 33(4):266-8. PubMed ID: 24631007
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a 'modern' pacemaker.
    Gimbel JR
    Europace; 2009 Sep; 11(9):1241-2. PubMed ID: 19556252
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cardiac tamponade after removal of temporary pacer wires.
    Mahon L; Bena JF; Morrison SM; Albert NM
    Am J Crit Care; 2012 Nov; 21(6):432-40. PubMed ID: 23117906
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.