These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 2296162)

  • 1. Wall shear stress distribution along the cusp of a tri-leaflet prosthetic valve.
    Einav S; Stolero D; Avidor JM; Elad D; Talbot L
    J Biomed Eng; 1990 Jan; 12(1):13-8. PubMed ID: 2296162
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Shear stress related blood damage along the cusp of a tri-leaflet prosthetic valve.
    Einav S; Reul H; Rau G; Elad D
    Int J Artif Organs; 1991 Nov; 14(11):716-20. PubMed ID: 1757159
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Two-dimensional color-mapping of turbulent shear stress distribution downstream of two aortic bioprosthetic valves in vitro.
    Nygaard H; Giersiepen M; Hasenkam JM; Reul H; Paulsen PK; Rovsing PE; Westphal D
    J Biomech; 1992 Apr; 25(4):429-40. PubMed ID: 1583021
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement of wall shear stress distal to a tri-leaflet valve in a rigid model of the aortic arch with branch flows.
    Nandy S; Tarbell JM
    J Biomech Eng; 1988 Aug; 110(3):172-9. PubMed ID: 3172735
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vitro pulsatile flow velocity and shear stress measurements in the vicinity of mechanical mitral heart valve prostheses.
    Woo YR; Yoganathan AP
    J Biomech; 1986; 19(1):39-51. PubMed ID: 3949815
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Estimation of the shear stress on the surface of an aortic valve leaflet.
    Weston MW; LaBorde DV; Yoganathan AP
    Ann Biomed Eng; 1999; 27(4):572-9. PubMed ID: 10468241
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Flush mounted hot film anemometer measurement of wall shear stress distal to a tri-leaflet valve for Newtonian and non-Newtonian blood analog fluids.
    Nandy S; Tarbell JM
    Biorheology; 1987; 24(5):483-500. PubMed ID: 2965604
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vitro pulsatile flow measurements in the vicinity of mechanical heart valves in the mitral flow chamber.
    Woo YR; Yoganathan AP
    Life Support Syst; 1986; 4(2):115-39. PubMed ID: 2943945
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Two-component laser Doppler anemometer for measurement of velocity and turbulent shear stress near prosthetic heart valves.
    Woo YR; Yoganathan AP
    Med Instrum; 1985; 19(5):224-31. PubMed ID: 2932625
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An instrument for the measurement of in vitro velocity and turbulent shear stress in the immediate vicinity of prosthetic heart valves.
    Woo YR; Yoganathan AP
    Life Support Syst; 1986; 4(1):47-62. PubMed ID: 2937981
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computational fluid dynamics simulation of transcatheter aortic valve degeneration.
    Dwyer HA; Matthews PB; Azadani A; Jaussaud N; Ge L; Guy TS; Tseng EE
    Interact Cardiovasc Thorac Surg; 2009 Aug; 9(2):301-8. PubMed ID: 19414489
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental technique of measuring dynamic fluid shear stress on the aortic surface of the aortic valve leaflet.
    Yap CH; Saikrishnan N; Tamilselvan G; Yoganathan AP
    J Biomech Eng; 2011 Jun; 133(6):061007. PubMed ID: 21744927
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Numerical and experimental investigations of pulsatile blood flow pattern through a dysfunctional mechanical heart valve.
    Smadi O; Hassan I; Pibarot P; Kadem L
    J Biomech; 2010 May; 43(8):1565-72. PubMed ID: 20188372
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A novel flex-stretch-flow bioreactor for the study of engineered heart valve tissue mechanobiology.
    Engelmayr GC; Soletti L; Vigmostad SC; Budilarto SG; Federspiel WJ; Chandran KB; Vorp DA; Sacks MS
    Ann Biomed Eng; 2008 May; 36(5):700-12. PubMed ID: 18253834
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vitro pulsatile flow velocity and turbulent shear stress measurements in the vicinity of mechanical aortic heart valve prostheses.
    Woo YR; Yoganathan AP
    Life Support Syst; 1985; 3(4):283-312. PubMed ID: 4068753
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mechanical stresses on closed cusps of porcine bioprosthetic valves: correlation with sites of calcification.
    Sabbah HN; Hamid MS; Stein PD
    Ann Thorac Surg; 1986 Jul; 42(1):93-6. PubMed ID: 3729623
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparative computational study of blood flow through prosthetic heart valves using the finite element method.
    Idelsohn SR; Costa LE; Ponso R
    J Biomech; 1985; 18(2):97-115. PubMed ID: 3988789
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Two-dimensional fluid-structure interaction simulation of bileaflet mechanical heart valve flow dynamics.
    Cheng R; Lai YG; Chandran KB
    J Heart Valve Dis; 2003 Nov; 12(6):772-80. PubMed ID: 14658820
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Velocity and shear stress distribution downstream of mechanical heart valves in pulsatile flow.
    Giersiepen M; Krause U; Knott E; Reul H; Rau G
    Int J Artif Organs; 1989 Apr; 12(4):261-9. PubMed ID: 2722280
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Principal stress analysis in LDA measurement of the flow field downstream of 19-mm Sorin Bicarbon heart valve.
    Barbaro V; Grigioni M; Daniele C; D'Avenio G
    Technol Health Care; 1998 Nov; 6(4):259-70. PubMed ID: 9924953
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.