These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 22967096)

  • 1. Detection of total and A1c-glycosylated hemoglobin in human whole blood using sandwich immunoassays on polydimethylsiloxane-based antibody microarrays.
    Chen HH; Wu CH; Tsai ML; Huang YJ; Chen SH
    Anal Chem; 2012 Oct; 84(20):8635-41. PubMed ID: 22967096
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Functional fluorinated modifications on a polyelectrolyte coated polydimethylsiloxane substrate for fabricating antibody microarrays.
    Chen HH; Sung WC; Liang SS; Chen SH
    Anal Chem; 2010 Sep; 82(18):7804-13. PubMed ID: 20799714
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood.
    Eissa S; Zourob M
    Sci Rep; 2017 Apr; 7(1):1016. PubMed ID: 28432344
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Multiple chemiluminescence immunoassay detection of the concentration ratio of glycosylated hemoglobin A1c to total hemoglobin in whole blood samples.
    Zhao H; Qiu X; Su E; Huang L; Zai Y; Liu Y; Chen H; Wang Z; Chen Z; Li S; Jin L; Deng Y; He N
    Anal Chim Acta; 2022 Feb; 1192():339379. PubMed ID: 35057955
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A hemoglobin A1C immunoassay method not affected by carbamylated hemoglobin.
    Rose AM; Tongate C; Valdes R
    Ann Clin Lab Sci; 1995; 25(1):13-9. PubMed ID: 7762964
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improved porous silicon microarray based prostate specific antigen immunoassay by optimized surface density of the capture antibody.
    Lee S; Kim S; Malm J; Jeong OC; Lilja H; Laurell T
    Anal Chim Acta; 2013 Sep; 796():108-14. PubMed ID: 24016590
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quality specifications for glycated hemoglobin A1c.
    Penttilä IM; Gävert J; Julkunen A; Rantanen T
    Ups J Med Sci; 1993; 98(3):395-9. PubMed ID: 7974871
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The relationship of plasma glucose and glycosylated hemoglobin A1C levels among nondiabetic trauma patients.
    Kopelman TR; O'Neill PJ; Kanneganti SR; Davis KM; Drachman DA
    J Trauma; 2008 Jan; 64(1):30-3; discussion 33-4. PubMed ID: 18188095
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Antibody-microarrays on hybrid polymeric thin film-coated slides for multiple-protein immunoassays.
    Zhou X; Zhou J
    Methods Mol Biol; 2007; 382():259-71. PubMed ID: 18220237
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An integrated microfluidic system for measurement of glycated hemoglobin levels by using an aptamer-antibody assay on magnetic beads.
    Chang KW; Li J; Yang CH; Shiesh SC; Lee GB
    Biosens Bioelectron; 2015 Jun; 68():397-403. PubMed ID: 25618372
    [TBL] [Abstract][Full Text] [Related]  

  • 11. "Macromolecules to PDMS transfer" as a general route for PDMS biochips.
    Heyries KA; Mandon CA; Ceriotti L; Ponti J; Colpo P; Blum LJ; Marquette CA
    Biosens Bioelectron; 2009 Jan; 24(5):1146-52. PubMed ID: 18676139
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation and interference study of hemoglobin A1c measured by turbidimetric inhibition immunoassay.
    Chang J; Hoke C; Ettinger B; Penerian G
    Am J Clin Pathol; 1998 Mar; 109(3):274-8. PubMed ID: 9495198
    [TBL] [Abstract][Full Text] [Related]  

  • 13. On-chip type cation-exchange chromatography with ferrocene-labeled anti-hemoglobin antibody and electrochemical detector for determination of hemoglobin A1c level.
    Tanaka T; Izawa K; Okochi M; Lim TK; Watanabe S; Harada M; Matsunaga T
    Anal Chim Acta; 2009 Apr; 638(2):186-90. PubMed ID: 19327458
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A lateral flow immunosensor for direct, sensitive, and highly selective detection of hemoglobin A1c in whole blood.
    Ang SH; Thevarajah TM; Woi PM; Alias YB; Khor SM
    J Chromatogr B Analyt Technol Biomed Life Sci; 2016 Mar; 1015-1016():157-165. PubMed ID: 26927875
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gold nanoparticles-coated magnetic microspheres as affinity matrix for detection of hemoglobin A1c in blood by microfluidic immunoassay.
    Chen SP; Yu XD; Xu JJ; Chen HY
    Biosens Bioelectron; 2011 Aug; 26(12):4779-84. PubMed ID: 21719268
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Production and characterization of monoclonal antibodies against non-A1c glycated hemoglobin.
    Steward LA; Wu VY; Shea E; Cohen MP
    J Immunol Methods; 1991 Jul; 140(2):145-51. PubMed ID: 2066560
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Toward one-step point-of-care immunodiagnostics using capillary-driven microfluidics and PDMS substrates.
    Gervais L; Delamarche E
    Lab Chip; 2009 Dec; 9(23):3330-7. PubMed ID: 19904397
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bead-based microarray immunoassay for lung cancer biomarkers using quantum dots as labels.
    Liu L; Wu S; Jing F; Zhou H; Jia C; Li G; Cong H; Jin Q; Zhao J
    Biosens Bioelectron; 2016 Jun; 80():300-306. PubMed ID: 26852198
    [TBL] [Abstract][Full Text] [Related]  

  • 19. PDMS microfluidic capillary systems for patterning proteins on surfaces and performing miniaturized immunoassays.
    Pla-Roca M; Juncker D
    Methods Mol Biol; 2011; 671():177-94. PubMed ID: 20967630
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Immunoturbidimetric assay of glycated hemoglobin.
    Metus P; Ruzzante N; Bonvicini P; Meneghetti M; Zaninotto M; Plebani M
    J Clin Lab Anal; 1999; 13(1):5-8. PubMed ID: 10025731
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.