BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

266 related articles for article (PubMed ID: 22971570)

  • 1. Serum testosterone quantitation by liquid chromatography-tandem mass spectrometry: interference from blood collection tubes.
    Shi RZ; van Rossum HH; Bowen RA
    Clin Biochem; 2012 Dec; 45(18):1706-9. PubMed ID: 22971570
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development and validation of a serum total testosterone liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay calibrated to NIST SRM 971.
    French D
    Clin Chim Acta; 2013 Jan; 415():109-17. PubMed ID: 23085208
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of a high throughput method for serum/plasma testosterone using liquid chromatography tandem mass spectrometry (LC-MS/MS).
    Singh RJ
    Steroids; 2008 Dec; 73(13):1339-44. PubMed ID: 18703076
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sex steroid hormone stability in serum tubes with and without separator gels.
    Hepburn S; Wright MJ; Boyder C; Sahertian RC; Lu B; Zhang R; White CP; Horvath AR
    Clin Chem Lab Med; 2016 Sep; 54(9):1451-9. PubMed ID: 26872314
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Direct total and free testosterone measurement by liquid chromatography tandem mass spectrometry across two different platforms.
    Rhea JM; French D; Molinaro RJ
    Clin Biochem; 2013 May; 46(7-8):656-64. PubMed ID: 23353132
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Simultaneous determination of androstenedione and testosterone in human serum by liquid chromatography-tandem mass spectrometry.
    Gallagher LM; Owen LJ; Keevil BG
    Ann Clin Biochem; 2007 Jan; 44(Pt 1):48-56. PubMed ID: 17270092
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Low serum testosterone assayed by liquid chromatography-tandem mass spectrometry. Comparison with five immunoassay techniques.
    Moal V; Mathieu E; Reynier P; Malthièry Y; Gallois Y
    Clin Chim Acta; 2007; 386(1-2):12-9. PubMed ID: 17706625
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Serum testosterone levels measured by isotope dilution-liquid chromatography-tandem mass spectrometry in postmenopausal women versus those in women who underwent bilateral oophorectomy.
    Bui HN; Struys EA; Martens F; de Ronde W; Thienpont LM; Kenemans P; Verhoeven MO; Jakobs C; Dijstelbloem HM; Blankenstein MA
    Ann Clin Biochem; 2010 May; 47(Pt 3):248-52. PubMed ID: 20406776
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Is calibration the cause of variation in liquid chromatography tandem mass spectrometry testosterone measurement?
    Owen LJ; MacDonald PR; Keevil BG
    Ann Clin Biochem; 2013 Jul; 50(Pt 4):368-70. PubMed ID: 23761381
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Direct measurement of serum free testosterone by ultrafiltration followed by liquid chromatography tandem mass spectrometry.
    Chen Y; Yazdanpanah M; Wang XY; Hoffman BR; Diamandis EP; Wong PY
    Clin Biochem; 2010 Mar; 43(4-5):490-6. PubMed ID: 20026023
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new rapid micromethod for the assay of phenobarbital from dried blood spots by LC-tandem mass spectrometry.
    la Marca G; Malvagia S; Filippi L; Luceri F; Moneti G; Guerrini R
    Epilepsia; 2009 Dec; 50(12):2658-62. PubMed ID: 19682026
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of a testosterone and dihydrotestosterone liquid chromatography tandem mass spectrometry assay: Interference and comparison with established methods.
    Wang C; Shiraishi S; Leung A; Baravarian S; Hull L; Goh V; Lee PW; Swerdloff RS
    Steroids; 2008 Dec; 73(13):1345-52. PubMed ID: 18579171
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry.
    Turpeinen U; Linko S; Itkonen O; Hämäläinen E
    Scand J Clin Lab Invest; 2008; 68(1):50-7. PubMed ID: 17852804
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluating and defining sample preparation procedures for DBS LC-MS/MS assays.
    Liu G; Patrone L; Snapp HM; Batog A; Valentine J; Cosma G; Tymiak A; Ji QC; Arnold ME
    Bioanalysis; 2010 Aug; 2(8):1405-14. PubMed ID: 21083341
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of salivary testosterone and androstendione by liquid chromatography-tandem mass spectrometry.
    Turpeinen U; Hämäläinen E; Haanpää M; Dunkel L
    Clin Chim Acta; 2012 Mar; 413(5-6):594-9. PubMed ID: 22178818
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Study of dried blood spots technique for the determination of dextromethorphan and its metabolite dextrorphan in human whole blood by LC-MS/MS.
    Liang X; Li Y; Barfield M; Ji QC
    J Chromatogr B Analyt Technol Biomed Life Sci; 2009 Mar; 877(8-9):799-806. PubMed ID: 19237324
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simultaneous quantitation of testosterone and estradiol in human cell line (H295R) by liquid chromatography/positive atmospheric pressure photoionization tandem mass spectrometry.
    Zhang F; Rick DL; Kan LH; Perala AW; Geter DR; LeBaron MJ; Bartels MJ
    Rapid Commun Mass Spectrom; 2011 Oct; 25(20):3123-30. PubMed ID: 21953968
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of a total testosterone assay using high-turbulence liquid chromatography tandem mass spectrometry: total and free testosterone reference ranges.
    Salameh WA; Redor-Goldman MM; Clarke NJ; Reitz RE; Caulfield MP
    Steroids; 2010 Feb; 75(2):169-75. PubMed ID: 19925815
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simultaneous determination of a selective adenosine 2A agonist, BMS-068645, and its acid metabolite in human plasma by liquid chromatography-tandem mass spectrometry--evaluation of the esterase inhibitor, diisopropyl fluorophosphate, in the stabilization of a labile ester-containing drug.
    Zeng J; Onthank D; Crane P; Unger S; Zheng N; Pasas-Farmer S; Arnold M
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jun; 852(1-2):77-84. PubMed ID: 17280881
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Rapid determination of serum testosterone by liquid chromatography-isotope dilution tandem mass spectrometry and a split sample comparison with three automated immunoassays.
    Chen Y; Yazdanpanah M; Hoffman BR; Diamandis EP; Wong PY
    Clin Biochem; 2009 Apr; 42(6):484-90. PubMed ID: 19109939
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.