BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 22975040)

  • 21. Evaluation of Coupling Efficiency in Round Window Vibroplasty With a New Handheld Probe.
    Schwarz D; Pazen D; Gostian AO; Lüers JC; Hüttenbrink KB
    Otol Neurotol; 2019 Jan; 40(1):e40-e47. PubMed ID: 30531640
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Noninvasive in vivo imaging reveals differences between tectorial membrane and basilar membrane traveling waves in the mouse cochlea.
    Lee HY; Raphael PD; Park J; Ellerbee AK; Applegate BE; Oghalai JS
    Proc Natl Acad Sci U S A; 2015 Mar; 112(10):3128-33. PubMed ID: 25737536
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Fast reverse propagation of sound in the living cochlea.
    He W; Fridberger A; Porsov E; Ren T
    Biophys J; 2010 Jun; 98(11):2497-505. PubMed ID: 20513393
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of forward (ear-canal) and reverse (round-window) sound stimulation of the cochlea.
    Stieger C; Rosowski JJ; Nakajima HH
    Hear Res; 2013 Jul; 301():105-14. PubMed ID: 23159918
    [TBL] [Abstract][Full Text] [Related]  

  • 25. In vivo impedance of the gerbil cochlear partition at auditory frequencies.
    Dong W; Olson ES
    Biophys J; 2009 Sep; 97(5):1233-43. PubMed ID: 19720011
    [TBL] [Abstract][Full Text] [Related]  

  • 26. No effect of prolonged pulsed high frequency ultrasound imaging of the basilar membrane on cochlear function or hair cell survival found in an initial study.
    Landry TG; Bance ML; Adamson RB; Brown JA
    Hear Res; 2018 Jun; 363():28-38. PubMed ID: 29605168
    [TBL] [Abstract][Full Text] [Related]  

  • 27. High-frequency sensitivity of the mature gerbil cochlea and its development.
    Overstreet EH; Richter CP; Temchin AN; Cheatham MA; Ruggero MA
    Audiol Neurootol; 2003; 8(1):19-27. PubMed ID: 12566689
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Direct measurement of intra-cochlear pressure waves.
    Olson ES
    Nature; 1999 Dec; 402(6761):526-9. PubMed ID: 10591211
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A self-mixing laser-diode interferometer for measuring basilar membrane vibrations without opening the cochlea.
    Lukashkin AN; Bashtanov ME; Russell IJ
    J Neurosci Methods; 2005 Oct; 148(2):122-9. PubMed ID: 15978669
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Timing of cochlear feedback: spatial and temporal representation of a tone across the basilar membrane.
    Nilsen KE; Russell IJ
    Nat Neurosci; 1999 Jul; 2(7):642-8. PubMed ID: 10404197
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Round window membrane motion with air conduction and bone conduction stimulation.
    Stenfelt S; Hato N; Goode RL
    Hear Res; 2004 Dec; 198(1-2):10-24. PubMed ID: 15567598
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Reflections on the role of a traveling wave along the basilar membrane in view of clinical and experimental findings.
    Sohmer H
    Eur Arch Otorhinolaryngol; 2015 Mar; 272(3):531-5. PubMed ID: 24740735
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Histological evaluation of damage in cat cochleas used for measurement of basilar membrane mechanics.
    Leonard DG; Khanna SM
    J Acoust Soc Am; 1984 Feb; 75(2):515-27. PubMed ID: 6699289
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Oscillations of the internal ear basilar membrane in the sonic and ultrasonic range from the data of mathematical analysis of the hydrodynamic model of the cochlea].
    Sagalovich BM; Krasil'nikov IuI; Burov AV
    Biofizika; 1990; 35(1):124-7. PubMed ID: 2346755
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Input impedance of the cochlea in cat.
    Lynch TJ; Nedzelnitsky V; Peake WT
    J Acoust Soc Am; 1982 Jul; 72(1):108-30. PubMed ID: 7108034
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Electrocochleographic and mechanical assessment of round window stimulation with an active middle ear prosthesis.
    Koka K; Holland NJ; Lupo JE; Jenkins HA; Tollin DJ
    Hear Res; 2010 May; 263(1-2):128-37. PubMed ID: 19720125
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Laser Doppler vibrometric assessment of middle ear motion in Thiel-embalmed heads.
    Stieger C; Candreia C; Kompis M; Herrmann G; Pfiffner F; Widmer D; Arnold A
    Otol Neurotol; 2012 Apr; 33(3):311-8. PubMed ID: 22377645
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Performance of the round window soft coupler for the backward stimulation of the cochlea in a temporal bone model.
    Gostian AO; Schwarz D; Mandt P; Anagiotos A; Ortmann M; Pazen D; Beutner D; Hüttenbrink KB
    Eur Arch Otorhinolaryngol; 2016 Nov; 273(11):3651-3661. PubMed ID: 27020274
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The reticular lamina and basilar membrane vibrations in the transverse direction in the basal turn of the living gerbil cochlea.
    He W; Burwood G; Porsov EV; Fridberger A; Nuttall AL; Ren T
    Sci Rep; 2022 Nov; 12(1):19810. PubMed ID: 36396720
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Third-window vibroplasty with an active middle ear implant: assessment of physiologic responses in a model of stapes fixation in Chinchilla lanigera.
    Lupo JE; Koka K; Jenkins HA; Tollin DJ
    Otol Neurotol; 2012 Apr; 33(3):425-31. PubMed ID: 22334156
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.