These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

87 related articles for article (PubMed ID: 22978437)

  • 1. Editorial: Lateral mass screws.
    Arnold PM
    J Neurosurg Spine; 2012 Nov; 17(5):388-9; author respnse 388-9. PubMed ID: 22978437
    [No Abstract]   [Full Text] [Related]  

  • 2. Computed tomography morphometric analysis for lateral mass screw placement in the pediatric subaxial cervical spine.
    Al-Shamy G; Cherian J; Mata JA; Patel AJ; Hwang SW; Jea A
    J Neurosurg Spine; 2012 Nov; 17(5):390-6. PubMed ID: 22978436
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Techniques and pitfalls of cervical lateral mass plate fixation.
    Muffoletto AJ; Hadjipavlou AG; Jensen RE; Nauta HJ; Necessary JT; Norcross-Nechay K
    Am J Orthop (Belle Mead NJ); 2000 Nov; 29(11):897-903. PubMed ID: 11079110
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of pedicle perforation by the cervical pedicle screw placement using plain radiographs: a comparison with computed tomography.
    Lee SH; Kim KT; Suk KS; Lee JH; Son ES; Kwack YH; Oh HS
    Spine (Phila Pa 1976); 2012 Feb; 37(4):280-5. PubMed ID: 21629168
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Considerations for the use of C7 crossing laminar screws in subaxial and cervicothoracic instrumentation.
    Ilgenfritz RM; Gandhi AA; Fredericks DC; Grosland NM; Smucker JD
    Spine (Phila Pa 1976); 2013 Feb; 38(4):E199-204. PubMed ID: 23169075
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cervicothoracic fusion performed using dual-diameter rods and polyaxial lateral mass screws. Case illustration.
    Deen HG
    J Neurosurg; 2002 Jul; 97(1 Suppl):148. PubMed ID: 12120640
    [No Abstract]   [Full Text] [Related]  

  • 7. Pedicle versus lateral mass screws.
    Vaccaro AR
    J Neurosurg Spine; 2010 Dec; 13(6):686; discussion 686-7. PubMed ID: 21121744
    [No Abstract]   [Full Text] [Related]  

  • 8. Feasibility of intralaminar, lateral mass, or pedicle axis vertebra screws in children under 10 years of age: a tomographic study.
    Cristante AF; Torelli AG; Kohlmann RB; Dias da Rocha I; Biraghi OL; Iutaka AS; Marcon RM; Oliveira RP; Pessoa de Barros Filho TE
    Neurosurgery; 2012 Apr; 70(4):835-8; discussion 838-9. PubMed ID: 21937932
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Radiographic evaluation of the technique for C1 lateral mass and C2 pedicle screw fixation in three hundred nineteen cases.
    Wang S; Wang C; Wood KB; Yan M; Zhou H
    Spine (Phila Pa 1976); 2011 Jan; 36(1):3-8. PubMed ID: 20693942
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cost effectiveness of subaxial fusion--lateral mass screws versus transarticular facet screws.
    Ray WZ; Ravindra VM; Jost GF; Bisson EF; Schmidt MH
    Neurosurg Focus; 2012 Jul; 33(1):E14. PubMed ID: 22746231
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a new technique for pedicle screw and Magerl screw insertion using a 3-dimensional image guide.
    Kawaguchi Y; Nakano M; Yasuda T; Seki S; Hori T; Kimura T
    Spine (Phila Pa 1976); 2012 Nov; 37(23):1983-8. PubMed ID: 22531473
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Placement of unilateral lag screw through the lateral mass of C-1: description of a novel technique.
    Tabbosha M; Dowdy J; Pait TG
    J Neurosurg Spine; 2013 Jul; 19(1):128-32. PubMed ID: 23662885
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anatomical considerations for cervical pedicle screw insertion: the use of multiplanar computerized tomography measurements in 122 consecutive clinical cases.
    Onibokun A; Khoo LT; Bistazzoni S; Chen NF; Sassi M
    Spine J; 2009 Sep; 9(9):729-34. PubMed ID: 19699462
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The feasibility of microscope-assisted "free-hand" C1 lateral mass screw insertion without fluoroscopy.
    Liu G; Buchowski JM; Shen H; Yeom JS; Riew KD
    Spine (Phila Pa 1976); 2008 Apr; 33(9):1042-9. PubMed ID: 18427327
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Subaxial cervical and cervicothoracic fixation techniques--indications, techniques, and outcomes.
    Pelton MA; Schwartz J; Singh K
    Orthop Clin North Am; 2012 Jan; 43(1):19-28, vii. PubMed ID: 22082626
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Complex pediatric cervical spine surgery using smaller nonspinal screws and plates and intraoperative computed tomography.
    Karandikar M; Mirza SK; Song K; Yang T; Krengel WF; Spratt KF; Avellino AM
    J Neurosurg Pediatr; 2012 Jun; 9(6):594-601. PubMed ID: 22656248
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Morphological characteristics of cervical spine in patients with athetoid cerebral palsy and the accuracy of pedicle screw placement.
    Kato S; Shoda N; Chikuda H; Seichi A; Takeshita K
    Spine (Phila Pa 1976); 2014 Apr; 39(8):E508-13. PubMed ID: 24480949
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Posterior C1-2 fusion with C1 lateral mass and C2 isthmic screws: accuracy of screw position, alignment and patient outcome.
    Ringel F; Reinke A; Stüer C; Meyer B; Stoffel M
    Acta Neurochir (Wien); 2012 Feb; 154(2):305-12. PubMed ID: 22200812
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Screw fixation of the upper cervical spine in the pediatric population. Clinical article.
    Haque A; Price AV; Sklar FH; Swift DM; Weprin BE; Sacco DJ
    J Neurosurg Pediatr; 2009 Jun; 3(6):529-33. PubMed ID: 19485741
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A novel screw guiding method with a screw guide template system for posterior C-2 fixation: clinical article.
    Kaneyama S; Sugawara T; Sumi M; Higashiyama N; Takabatake M; Mizoi K
    J Neurosurg Spine; 2014 Aug; 21(2):231-8. PubMed ID: 24785974
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.