BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

266 related articles for article (PubMed ID: 22986896)

  • 1. Inter-individual variance and cardiac cycle dependency of aortic root dimensions and shape as assessed by ECG-gated multi-slice computed tomography in patients with severe aortic stenosis prior to transcatheter aortic valve implantation: is it crucial for correct sizing?
    Lehmkuhl L; Foldyna B; Von Aspern K; Lücke C; Grothoff M; Nitzsche S; Kempfert J; Haensig M; Rastan A; Walther T; Mohr FW; Gutberlet M
    Int J Cardiovasc Imaging; 2013 Mar; 29(3):693-703. PubMed ID: 22986896
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effective diameter of the aortic annulus prior to transcatheter aortic valve implantation: influence of area-based versus perimeter-based calculation.
    von Aspern K; Foldyna B; Etz CD; Hoyer A; Girrbach F; Holzhey D; Lücke C; Grothoff M; Linke A; Mohr FW; Gutberlet M; Lehmkuhl L
    Int J Cardiovasc Imaging; 2015 Jan; 31(1):163-9. PubMed ID: 25165022
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Conformational pulsatile changes of the aortic annulus: impact on prosthesis sizing by computed tomography for transcatheter aortic valve replacement.
    Blanke P; Russe M; Leipsic J; Reinöhl J; Ebersberger U; Suranyi P; Siepe M; Pache G; Langer M; Schoepf UJ
    JACC Cardiovasc Interv; 2012 Sep; 5(9):984-94. PubMed ID: 22995887
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Aortic root dimensions among patients with severe aortic stenosis undergoing transcatheter aortic valve replacement.
    Buellesfeld L; Stortecky S; Kalesan B; Gloekler S; Khattab AA; Nietlispach F; Delfine V; Huber C; Eberle B; Meier B; Wenaweser P; Windecker S
    JACC Cardiovasc Interv; 2013 Jan; 6(1):72-83. PubMed ID: 23347864
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimal prosthesis sizing in transcatheter aortic valve implantation by exclusive use of three-dimensional transoesophageal echocardiography.
    Kretzschmar D; Lauten A; Goebel B; Doenst T; Poerner TC; Ferrari M; Figulla HR; Hamadanchi A
    Clin Physiol Funct Imaging; 2016 Mar; 36(2):99-105. PubMed ID: 25316588
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Aortic annulus and root characteristics in severe aortic stenosis due to bicuspid aortic valve and tricuspid aortic valves: implications for transcatheter aortic valve therapies.
    Philip F; Faza NN; Schoenhagen P; Desai MY; Tuzcu EM; Svensson LG; Kapadia SR
    Catheter Cardiovasc Interv; 2015 Aug; 86(2):E88-98. PubMed ID: 25914355
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation.
    Sherif MA; Ince H; Maniuc O; Reiter T; Voelker W; Ertl G; Öner A
    BMC Cardiovasc Disord; 2015 Dec; 15():181. PubMed ID: 26715337
    [TBL] [Abstract][Full Text] [Related]  

  • 8. CT predictors of post-procedural aortic regurgitation in patients referred for transcatheter aortic valve implantation: an analysis of 105 patients.
    Marwan M; Achenbach S; Ensminger SM; Pflederer T; Ropers D; Ludwig J; Weyand M; Daniel WG; Arnold M
    Int J Cardiovasc Imaging; 2013 Jun; 29(5):1191-8. PubMed ID: 23420354
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation.
    Watanabe Y; Morice MC; Bouvier E; Leong T; Hayashida K; Lefèvre T; Hovasse T; Romano M; Chevalier B; Donzeau-Gouge P; Farge A; Cormier B; Garot P
    JACC Cardiovasc Interv; 2013 Sep; 6(9):955-64. PubMed ID: 23954060
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determinants of aortic regurgitation after transcatheter aortic valve implantation. An observational study using multi-slice computed tomography-guided sizing.
    Rahhab Z; El Faquir N; Rodríguez-Olivares R; Ren C; van Mieghem N; Geleijnse ML; Schultz C; van Domburg R; de Jaegere PP
    J Cardiovasc Surg (Torino); 2017 Aug; 58(4):598-605. PubMed ID: 28128540
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Incidence and severity of paravalvular aortic regurgitation with multidetector computed tomography nominal area oversizing or undersizing after transcatheter heart valve replacement with the Sapien 3: a comparison with the Sapien XT.
    Yang TH; Webb JG; Blanke P; Dvir D; Hansson NC; Nørgaard BL; Thompson CR; Thomas M; Wendler O; Vahanian A; Himbert D; Kodali SK; Hahn RT; Thourani VH; Schymik G; Precious B; Berger A; Wood DA; Pibarot P; Rodés-Cabau J; Jaber WA; Leon MB; Walther T; Leipsic J
    JACC Cardiovasc Interv; 2015 Mar; 8(3):462-471. PubMed ID: 25790764
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of aortic root measurements in patients undergoing transapical aortic valve implantation (TA-AVI) using three-dimensional rotational angiography (3D-RA) and multislice computed tomography (MSCT): differences and variability.
    Lehmkuhl LH; von Aspern K; Foldyna B; Grothoff M; Nitzsche S; Kempfert J; Rastan A; Linke A; Mohr FW; Noettling A; Walther T; Gutberlet M
    Int J Cardiovasc Imaging; 2013 Feb; 29(2):417-24. PubMed ID: 22710987
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement.
    Freeman M; Webb JG; Willson AB; Wheeler M; Blanke P; Moss RR; Thompson CR; Munt B; Norgaard BL; Yang TH; Min JK; Poulsen S; Hansson NC; Binder RK; Toggweiler S; Hague C; Wood DA; Pibarot P; Leipsic J
    J Cardiovasc Comput Tomogr; 2013; 7(4):248-55. PubMed ID: 24148778
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole.
    Bertaso AG; Wong DT; Liew GY; Cunnington MS; Richardson JD; Thomson VS; Lorraine B; Kourlis G; Leech D; Worthley MI; Worthley SG
    Int J Cardiovasc Imaging; 2012 Dec; 28(8):2091-8. PubMed ID: 22318541
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Inverse Relationship Between Membranous Septal Length and the Risk of Atrioventricular Block in Patients Undergoing Transcatheter Aortic Valve Implantation.
    Hamdan A; Guetta V; Klempfner R; Konen E; Raanani E; Glikson M; Goitein O; Segev A; Barbash I; Fefer P; Spiegelstein D; Goldenberg I; Schwammenthal E
    JACC Cardiovasc Interv; 2015 Aug; 8(9):1218-1228. PubMed ID: 26292585
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Preparatory balloon aortic valvuloplasty during transcatheter aortic valve implantation for improved valve sizing.
    Patsalis PC; Al-Rashid F; Neumann T; Plicht B; Hildebrandt HA; Wendt D; Thielmann M; Jakob HG; Heusch G; Erbel R; Kahlert P
    JACC Cardiovasc Interv; 2013 Sep; 6(9):965-71. PubMed ID: 24050862
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation.
    Bernhardt P; Rodewald C; Seeger J; Gonska B; Buckert D; Radermacher M; Hombach V; Rottbauer W; Wöhrle J
    Clin Res Cardiol; 2016 Mar; 105(3):273-8. PubMed ID: 26395021
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automatic 3D aortic annulus sizing by computed tomography in the planning of transcatheter aortic valve implantation.
    Queirós S; Dubois C; Morais P; Adriaenssens T; Fonseca JC; Vilaça JL; D'hooge J
    J Cardiovasc Comput Tomogr; 2017; 11(1):25-32. PubMed ID: 28063844
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Three-dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on postprocedural paravalvular aortic regurgitation.
    Hansson NC; Thuesen L; Hjortdal VE; Leipsic J; Andersen HR; Poulsen SH; Webb JG; Christiansen EH; Rasmussen LE; Krusell LR; Terp K; Klaaborg KE; Tang M; Lassen JF; Bøtker HE; Nørgaard BL
    Catheter Cardiovasc Interv; 2013 Nov; 82(6):977-86. PubMed ID: 23703899
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Do CTA measurements of annular diameter, perimeter and area result in different TAVI prosthesis sizes?
    Horehledova B; Mihl C; Hendriks BMF; Eijsvoogel NG; Vainer J; Veenstra LF; Wildberger JE; Das M
    Int J Cardiovasc Imaging; 2018 Nov; 34(11):1819-1829. PubMed ID: 29909590
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.