These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 22996992)

  • 1. On- and off-pump coronary artery bypass surgery. The heart surgeon should master both techniques.
    Gomes WJ
    Rev Bras Cir Cardiovasc; 2012; 27(2):v-viii. PubMed ID: 22996992
    [No Abstract]   [Full Text] [Related]  

  • 2. Coronary artery surgery and extracorporeal circulation: the search for a new standard.
    Pillai JB; Suri RM
    J Cardiothorac Vasc Anesth; 2008 Aug; 22(4):594-610. PubMed ID: 18662641
    [No Abstract]   [Full Text] [Related]  

  • 3. Minimal extracorporeal circulation is a promising alternative for off-pump revascularization in adults.
    Puehler T; Philipp A; Schmid C
    J Thorac Cardiovasc Surg; 2010 Jan; 139(1):233; author reply 233-4. PubMed ID: 20106368
    [No Abstract]   [Full Text] [Related]  

  • 4. [Coronary revascularization with extracorporeal circulation, aortic clamping or OPCAB: does the method's choice influence the results?].
    Coelho P; Gomes V; Silva ND; Fragata I; Ramos JS; Fragata J
    Rev Port Cir Cardiotorac Vasc; 2005; 12(1):15-9. PubMed ID: 15895122
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Systemic and myocardial inflammatory response in coronary artery bypass graft surgery with miniaturized extracorporeal circulation: differences with a standard circuit and off-pump technique in a randomized clinical trial.
    Formica F; Mariani S; Broccolo F; Caruso R; Corti F; D'Alessandro S; Amigoni P; Sangalli F; Paolini G
    ASAIO J; 2013; 59(6):600-6. PubMed ID: 24172265
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Myocardial revascularization with miniaturized extracorporeal circulation versus off pump: Evaluation of systemic and myocardial inflammatory response in a prospective randomized study.
    Formica F; Broccolo F; Martino A; Sciucchetti J; Giordano V; Avalli L; Radaelli G; Ferro O; Corti F; Cocuzza C; Paolini G
    J Thorac Cardiovasc Surg; 2009 May; 137(5):1206-12. PubMed ID: 19379993
    [TBL] [Abstract][Full Text] [Related]  

  • 7. How minimalized extracorporeal circulation compares with the off-pump technique in coronary artery bypass grafting.
    Harling L; Warren OJ; Rogers PL; Watret AL; Choong AM; Darzi A; Angelini GD; Athanasiou T
    ASAIO J; 2010; 56(5):446-56. PubMed ID: 20613493
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Flowmetry of left internal thoracic artery graft to left anterior descending artery: comparison between on-pump and off-pump surgery.
    Cerqueira Neto FM; Guedes MA; Soares LE; Almeida GS; Guimarães AR; Barreto MA; Porto EC; Rabelo Júnior A
    Rev Bras Cir Cardiovasc; 2012; 27(2):283-9. PubMed ID: 22996980
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Miniaturized extracorporeal circulation vs. off-pump coronary artery bypass grafting: what the evidence shows?
    Harling L; Punjabi PP; Athanasiou T
    Perfusion; 2011 Sep; 26 Suppl 1():40-7. PubMed ID: 21933821
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A differential release of matrix metalloproteinases 9 and 2 during coronary artery bypass grafting and off-pump coronary artery bypass surgery.
    Sokal A; Zembala M; Radomski A; Kocher A; Pacholewicz J; Los J; Jedrzejczyk E; Zembala M; Radomski M
    J Thorac Cardiovasc Surg; 2009 May; 137(5):1218-24. PubMed ID: 19379995
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Minimal extracorporeal circulation: an alternative for on-pump and off-pump coronary revascularization.
    Puehler T; Haneya A; Philipp A; Wiebe K; Keyser A; Rupprecht L; Hirt S; Kobuch R; Diez C; Hilker M; Schmid C
    Ann Thorac Surg; 2009 Mar; 87(3):766-72. PubMed ID: 19231386
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Minimally Invasive Extracorporeal Circulation Circuit Is Not Inferior to Off-Pump Coronary Artery Bypass Grafting: Meta-Analysis Using the Bayesian Method.
    Winkler B; Heinisch PP; Gahl B; Aghlmandi S; Jenni HJ; Carrel TP
    Ann Thorac Surg; 2017 Jan; 103(1):342-350. PubMed ID: 27780561
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Beating-heart coronary artery bypass surgery with the help of mini extracorporeal circulation for very high-risk patients.
    Munos E; Calderon J; Pillois X; Lafitte S; Ouattara A; Labrousse L; Roques X; Barandon L
    Perfusion; 2011 Mar; 26(2):123-31. PubMed ID: 21242193
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Risk factors for conversion to cardiopulmonary bypass during off-pump coronary artery bypass surgery.
    Chowdhury R; White D; Kilgo P; Puskas JD; Thourani VH; Chen EP; Lattouf OM; Cooper WA; Myung RJ; Guyton RA; Halkos ME
    Ann Thorac Surg; 2012 Jun; 93(6):1936-41; discussion 1942. PubMed ID: 22503849
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In-hospital outcomes of off-pump multivessel total arterial and conventional coronary artery bypass grafting: single surgeon, single center experience.
    Raja SG; Siddiqui H; Ilsley CD; Amrani M
    Ann Thorac Surg; 2009 Jul; 88(1):47-52. PubMed ID: 19559187
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effects of on-pump and off-pump coronary artery bypass grafting on intraoperative graft flow in arterial and venous conduits defined by a flow/pressure ratio.
    Balacumaraswami L; Abu-Omar Y; Selvanayagam J; Pigott D; Taggart DP
    J Thorac Cardiovasc Surg; 2008 Mar; 135(3):533-9. PubMed ID: 18329465
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Metabolomic profiling in patients undergoing Off-Pump or On-Pump coronary artery bypass surgery.
    Kirov H; Schwarzer M; Neugebauer S; Faerber G; Diab M; Doenst T
    BMC Cardiovasc Disord; 2017 Apr; 17(1):93. PubMed ID: 28381258
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prospective randomized comparison of coronary bypass grafting with minimal extracorporeal circulation system (MECC) versus off-pump coronary surgery.
    Mazzei V; Nasso G; Salamone G; Castorino F; Tommasini A; Anselmi A
    Circulation; 2007 Oct; 116(16):1761-7. PubMed ID: 17875971
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Perioperative Outcomes, Transfusion Requirements, and Inflammatory Response After Coronary Artery Bypass Grafting With Off-Pump, Mini-Extracorporeal, and On-Pump Circulation Techniques.
    Brinkman WT; Squiers JJ; Filardo G; Arsalan M; Smith RL; Moore D; Mack MJ; DiMaio JM
    J Investig Med; 2015 Dec; 63(8):916-20. PubMed ID: 26448506
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Safety and efficacy of miniaturized extracorporeal circulation when compared with off-pump and conventional coronary artery bypass grafting: evidence synthesis from a comprehensive Bayesian-framework network meta-analysis of 134 randomized controlled trials involving 22 778 patients.
    Kowalewski M; Pawliszak W; Raffa GM; Malvindi PG; Kowalkowska ME; Zaborowska K; Kowalewski J; Tarelli G; Taggart DP; Anisimowicz L
    Eur J Cardiothorac Surg; 2016 May; 49(5):1428-40. PubMed ID: 26537755
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.