BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

470 related articles for article (PubMed ID: 22997004)

  • 21. Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation.
    Takagi K; Latib A; Al-Lamee R; Mussardo M; Montorfano M; Maisano F; Godino C; Chieffo A; Alfieri O; Colombo A
    Catheter Cardiovasc Interv; 2011 Sep; 78(3):432-43. PubMed ID: 21793168
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Percutaneous Transvenous Transseptal Transcatheter Valve Implantation in Failed Bioprosthetic Mitral Valves, Ring Annuloplasty, and Severe Mitral Annular Calcification.
    Eleid MF; Cabalka AK; Williams MR; Whisenant BK; Alli OO; Fam N; Pollak PM; Barrow F; Malouf JF; Nishimura RA; Joyce LD; Dearani JA; Rihal CS
    JACC Cardiovasc Interv; 2016 Jun; 9(11):1161-74. PubMed ID: 27085576
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Impact of patient-prosthesis mismatch after transcatheter aortic valve-in-valve implantation in degenerated bioprostheses.
    Seiffert M; Conradi L; Baldus S; Knap M; Schirmer J; Franzen O; Koschyk D; Meinertz T; Reichenspurner H; Treede H
    J Thorac Cardiovasc Surg; 2012 Mar; 143(3):617-24. PubMed ID: 22169448
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of severe left ventricular systolic dysfunction on hospital outcome after transcatheter aortic valve implantation or surgical aortic valve replacement: results from a propensity-matched population of the Italian OBSERVANT multicenter study.
    Onorati F; D'Errigo P; Grossi C; Barbanti M; Ranucci M; Covello DR; Rosato S; Maraschini A; Santoro G; Tamburino C; Seccareccia F; Santini F; Menicanti L;
    J Thorac Cardiovasc Surg; 2014 Feb; 147(2):568-75. PubMed ID: 24263007
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A prospective "oversizing" strategy of the Edwards SAPIEN bioprosthesis: results and impact on aortic regurgitation.
    Samim M; Stella PR; Agostoni P; Kluin J; Ramjankhan F; Sieswerda G; Budde R; van der Linden M; Juthier F; Banfi C; Hurt C; Samim M; Hillaert M; van Herwerden L; Bertrand ME; Doevendans PA; Van Belle E
    J Thorac Cardiovasc Surg; 2013 Feb; 145(2):398-405. PubMed ID: 22377664
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Transcatheter aortic valve implantation for pure severe native aortic valve regurgitation.
    Roy DA; Schaefer U; Guetta V; Hildick-Smith D; Möllmann H; Dumonteil N; Modine T; Bosmans J; Petronio AS; Moat N; Linke A; Moris C; Champagnac D; Parma R; Ochala A; Medvedofsky D; Patterson T; Woitek F; Jahangiri M; Laborde JC; Brecker SJ
    J Am Coll Cardiol; 2013 Apr; 61(15):1577-84. PubMed ID: 23433565
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves.
    Dvir D; Webb JG; Bleiziffer S; Pasic M; Waksman R; Kodali S; Barbanti M; Latib A; Schaefer U; Rodés-Cabau J; Treede H; Piazza N; Hildick-Smith D; Himbert D; Walther T; Hengstenberg C; Nissen H; Bekeredjian R; Presbitero P; Ferrari E; Segev A; de Weger A; Windecker S; Moat NE; Napodano M; Wilbring M; Cerillo AG; Brecker S; Tchetche D; Lefèvre T; De Marco F; Fiorina C; Petronio AS; Teles RC; Testa L; Laborde JC; Leon MB; Kornowski R;
    JAMA; 2014 Jul; 312(2):162-70. PubMed ID: 25005653
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Direct transcatheter aortic valve implantation with self-expandable bioprosthesis: feasibility and safety.
    Fiorina C; Maffeo D; Curello S; Lipartiti F; Chizzola G; D'Aloia A; Adamo M; Mastropierro R; Gavazzi E; Ciccarese C; Chiari E; Ettori F
    Cardiovasc Revasc Med; 2014 Jun; 15(4):200-3. PubMed ID: 24746865
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Transfemoral implantation of transcatheter heart valves after deterioration of mitral bioprosthesis or previous ring annuloplasty.
    Bouleti C; Fassa AA; Himbert D; Brochet E; Ducrocq G; Nejjari M; Ghodbane W; Depoix JP; Nataf P; Vahanian A
    JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt A):83-91. PubMed ID: 25616821
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Transcatheter Aortic and Mitral Valve-in-Valve Implantation for Failed Surgical Bioprosthetic Valves: An 8-Year Single-Center Experience.
    Ye J; Cheung A; Yamashita M; Wood D; Peng D; Gao M; Thompson CR; Munt B; Moss RR; Blanke P; Leipsic J; Dvir D; Webb JG
    JACC Cardiovasc Interv; 2015 Nov; 8(13):1735-44. PubMed ID: 26476608
    [TBL] [Abstract][Full Text] [Related]  

  • 31. What is the best approach in a patient with a failed aortic bioprosthetic valve: transcatheter aortic valve replacement or redo aortic valve replacement?
    Tourmousoglou C; Rao V; Lalos S; Dougenis D
    Interact Cardiovasc Thorac Surg; 2015 Jun; 20(6):837-43. PubMed ID: 25754372
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Performance of valve-in-valve for severe para-prosthetic leaks due to inadequate transcatheter aortic valve implantation.
    Napodano M; Gasparetto V; Tarantini G; Fraccaro C; Yzeiraj E; Gerosa G; Isabella G; Iliceto S
    Catheter Cardiovasc Interv; 2011 Dec; 78(7):996-1003. PubMed ID: 22114036
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Direct aortic access for transcatheter self-expanding aortic bioprosthetic valves implantation.
    Bruschi G; de Marco F; Botta L; Cannata A; Oreglia J; Colombo P; Barosi A; Colombo T; Nonini S; Paino R; Klugmann S; Martinelli L
    Ann Thorac Surg; 2012 Aug; 94(2):497-503. PubMed ID: 22633495
    [TBL] [Abstract][Full Text] [Related]  

  • 34. CoreValve degeneration with severe transvalvular aortic regurgitation treated with valve-in-valve implantation.
    Sinning JM; Vasa-Nicotera M; Werner N; Zimmer S; Mellert F; Welz A; Grube E; Nickenig G; Hammerstingl C
    JACC Cardiovasc Interv; 2014 Jul; 7(7):e71-2. PubMed ID: 24954574
    [No Abstract]   [Full Text] [Related]  

  • 35. Transcatheter aortic valve implantation for treatment of failing homograft with preexisting mechanical mitral prosthesis.
    Attia R; Bapat V
    Catheter Cardiovasc Interv; 2013 Aug; 82(2):324-7. PubMed ID: 22120953
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Treatment and prevention of aortic regurgitation after transcatheter aortic valve implantation.
    Hayashida K; Lefèvre T
    EuroIntervention; 2012 Sep; 8 Suppl Q():Q34-40. PubMed ID: 22995110
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Management of paravalvular regurgitation after Edwards SAPIEN transcatheter aortic valve replacement: management of paravalvular regurgitation after TAVR.
    Martinez CA; Singh V; O'Neill BP; Alfonso CE; Bilsker MS; Martinez Clark P; Williams D; Cohen MG; Heldman AW; O'Neill WW
    Catheter Cardiovasc Interv; 2013 Aug; 82(2):300-11. PubMed ID: 23580318
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Balloon valuloplasty prior to transcatheter valve-in-valve implantation in a degenerated Mitroflow aortic bioprosthesis.
    Cerillo AG; Berti S; Glauber M
    Catheter Cardiovasc Interv; 2013 May; 81(6):1075-8. PubMed ID: 22744728
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Transapical transcatheter aortic valve for severe aortic regurgitation: expanding the limits.
    Wendt D; Kahlert P; Pasa S; El-Chilali K; Al-Rashid F; Tsagakis K; Dohle DS; Erbel R; Jakob H; Thielmann M
    JACC Cardiovasc Interv; 2014 Oct; 7(10):1159-67. PubMed ID: 25129668
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Transcatheter aortic valve implantation for high risk patients with severe aortic stenosis using the Edwards Sapien balloon-expandable bioprosthesis: a single centre study with immediate and medium-term outcomes.
    Osten MD; Feindel C; Greutmann M; Chamberlain K; Meineri M; Rubin B; Mezody M; Ivanov J; Butany J; Horlick EM
    Catheter Cardiovasc Interv; 2010 Mar; 75(4):475-85. PubMed ID: 19937781
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 24.