BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

217 related articles for article (PubMed ID: 23001515)

  • 1. Limits on the spatial resolution of monolithic scintillators read out by APD arrays.
    van der Laan DJ; Maas MC; Bruyndonckx P; Schaart DR
    Phys Med Biol; 2012 Oct; 57(20):6479-96. PubMed ID: 23001515
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Performance of long rectangular semi-monolithic scintillator PET detectors.
    Zhang X; Wang X; Ren N; Hu B; Ding B; Kuang Z; Wu S; Sang Z; Hu Z; Du J; Liang D; Liu X; Zheng H; Yang Y
    Med Phys; 2019 Apr; 46(4):1608-1619. PubMed ID: 30723932
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Towards monolithic scintillator based TOF-PET systems: practical methods for detector calibration and operation.
    Borghi G; Tabacchini V; Schaart DR
    Phys Med Biol; 2016 Jul; 61(13):4904-28. PubMed ID: 27285955
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Model of the point spread function of monolithic scintillator PET detectors for perpendicular incidence.
    Maas MC; van der Laan DJ; van Eijk CW; Schaart DR; Beekman FJ; Bruyndonckx P; Lemaître C
    Med Phys; 2010 Apr; 37(4):1904-13. PubMed ID: 20443512
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Performance of a SiPM based semi-monolithic scintillator PET detector.
    Zhang X; Wang X; Ren N; Kuang Z; Deng X; Fu X; Wu S; Sang Z; Hu Z; Liang D; Liu X; Zheng H; Yang Y
    Phys Med Biol; 2017 Sep; 62(19):7889-7904. PubMed ID: 28858853
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A novel, SiPM-array-based, monolithic scintillator detector for PET.
    Schaart DR; van Dam HT; Seifert S; Vinke R; Dendooven P; Löhner H; Beekman FJ
    Phys Med Biol; 2009 Jun; 54(11):3501-12. PubMed ID: 19443953
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Time-based position estimation in monolithic scintillator detectors.
    Tabacchini V; Borghi G; Schaart DR
    Phys Med Biol; 2015 Jul; 60(14):5513-25. PubMed ID: 26133784
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An edge-readout, multilayer detector for positron emission tomography.
    Li X; Ruiz-Gonzalez M; Furenlid LR
    Med Phys; 2018 Jun; 45(6):2425-2438. PubMed ID: 29635734
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction.
    Maas MC; Schaart DR; van der Laan DJ; Bruyndonckx P; Lemaître C; Beekman FJ; van Eijk CW
    Phys Med Biol; 2009 Apr; 54(7):1893-908. PubMed ID: 19265203
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analytical calculation of the lower bound on timing resolution for PET scintillation detectors comprising high-aspect-ratio crystal elements.
    Cates JW; Vinke R; Levin CS
    Phys Med Biol; 2015 Jul; 60(13):5141-61. PubMed ID: 26083559
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance evaluation of side-by-side optically coupled monolithic LYSO crystals.
    Freire M; Echegoyen S; Gonzalez-Montoro A; Sanchez F; Gonzalez AJ
    Med Phys; 2022 Aug; 49(8):5616-5626. PubMed ID: 35689501
    [TBL] [Abstract][Full Text] [Related]  

  • 12. First characterization of a digital SiPM based time-of-flight PET detector with 1 mm spatial resolution.
    Seifert S; van der Lei G; van Dam HT; Schaart DR
    Phys Med Biol; 2013 May; 58(9):3061-74. PubMed ID: 23587636
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A method to achieve spatial linearity and uniform resolution at the edges of monolithic scintillation crystal detectors.
    Vinke R; Levin CS
    Phys Med Biol; 2014 Jun; 59(12):2975-95. PubMed ID: 24841984
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Sub-200 ps CRT in monolithic scintillator PET detectors using digital SiPM arrays and maximum likelihood interaction time estimation.
    van Dam HT; Borghi G; Seifert S; Schaart DR
    Phys Med Biol; 2013 May; 58(10):3243-57. PubMed ID: 23611889
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optical simulation study on the spatial resolution of a thick monolithic PET detector.
    Stockhoff M; Van Holen R; Vandenberghe S
    Phys Med Biol; 2019 Sep; 64(19):195003. PubMed ID: 31416055
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The lower bound on the timing resolution of scintillation detectors.
    Seifert S; van Dam HT; Schaart DR
    Phys Med Biol; 2012 Apr; 57(7):1797-814. PubMed ID: 22410975
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A semi-monolithic detector providing intrinsic DOI-encoding and sub-200 ps CRT TOF-capabilities for clinical PET applications.
    Mueller F; Naunheim S; Kuhl Y; Schug D; Solf T; Schulz V
    Med Phys; 2022 Dec; 49(12):7469-7488. PubMed ID: 36259245
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET.
    Yeom JY; Vinke R; Levin CS
    Med Phys; 2014 Dec; 41(12):122501. PubMed ID: 25471979
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A high resolution SPECT detector based on thin continuous LYSO.
    Deprez K; Van Holen R; Vandenberghe S
    Phys Med Biol; 2014 Jan; 59(1):153-71. PubMed ID: 24334315
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development of a dual-ended readout detector with segmented crystal bars made using a subsurface laser engraving technique.
    Mohammadi A; Yoshida E; Nishikido F; Nitta M; Shimizu K; Sakai T; Yamaya T
    Phys Med Biol; 2018 Jan; 63(2):025019. PubMed ID: 29176052
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.