82 related articles for article (PubMed ID: 2300633)
1. The radial forearm flap: a biomechanical study of the osteotomized radius.
Swanson E; Boyd JB; Mulholland RS
Plast Reconstr Surg; 1990 Feb; 85(2):267-72. PubMed ID: 2300633
[TBL] [Abstract][Full Text] [Related]
2. The radial forearm flap: a biomechanical study of donor-site morbidity utilizing sheep tibia.
Meland NB; Maki S; Chao EY; Rademaker B
Plast Reconstr Surg; 1992 Nov; 90(5):763-73. PubMed ID: 1410028
[TBL] [Abstract][Full Text] [Related]
3. The fate of the osteotomized free radial forearm osteocutaneous flap in mandible reconstruction.
Thoma A; Allen M; Tadeson BH; Archibald S; Jackson S; Young JE
J Reconstr Microsurg; 1995 May; 11(3):215-9. PubMed ID: 7650648
[TBL] [Abstract][Full Text] [Related]
4. Osteocutaneous radial forearm free flaps. The necessity of internal fixation of the donor-site defect to prevent pathological fracture.
Bowers KW; Edmonds JL; Girod DA; Jayaraman G; Chua CP; Toby EB
J Bone Joint Surg Am; 2000 May; 82(5):694-704. PubMed ID: 10819280
[TBL] [Abstract][Full Text] [Related]
5. The pronator quadratus muscle flap: coverage of the osteotomized radius following elevation of the radial forearm flap.
Kupfer D; Lister G
Plast Reconstr Surg; 1992 Dec; 90(6):1093-5. PubMed ID: 1448509
[TBL] [Abstract][Full Text] [Related]
6. Biomechanical study of prophylactic internal fixation of the radial osteocutaneous donor site using the sheep tibia model.
Avery CM; Best A; Patterson P; Rolton J; Ponter AR
Br J Oral Maxillofac Surg; 2007 Sep; 45(6):441-6. PubMed ID: 17188407
[TBL] [Abstract][Full Text] [Related]
7. The effects of distal radius fracture malalignment on forearm rotation: a cadaveric study.
Bronstein AJ; Trumble TE; Tencer AF
J Hand Surg Am; 1997 Mar; 22(2):258-62. PubMed ID: 9195423
[TBL] [Abstract][Full Text] [Related]
8. Both-bone forearm osteotomy for supination contracture: a cadaver model.
Hutchinson DT; Wang AA; Ryssman D; Brown NA
J Hand Surg Am; 2006; 31(6):968-72. PubMed ID: 16843157
[TBL] [Abstract][Full Text] [Related]
9. The use of a circular external skeletal fixation device for the management of long bone osteotomies in large ruminants: an experimental study.
Aithal HP; Singh GR; Hoque M; Maiti SK; Kinjavdekar P; Pawde AM; Setia HC;
J Vet Med A Physiol Pathol Clin Med; 2004 Aug; 51(6):284-93. PubMed ID: 15485564
[TBL] [Abstract][Full Text] [Related]
10. Simultaneous radial closing wedge and ulnar shortening osteotomies for distal radius malunion.
Wada T; Isogai S; Kanaya K; Tsukahara T; Yamashita T
J Hand Surg Am; 2004 Mar; 29(2):264-72. PubMed ID: 15043900
[TBL] [Abstract][Full Text] [Related]
11. Percutaneous pinning of distal radius fractures: a biomechanical study.
Naidu SH; Capo JT; Moulton M; Ciccone W; Radin A
J Hand Surg Am; 1997 Mar; 22(2):252-7. PubMed ID: 9195422
[TBL] [Abstract][Full Text] [Related]
12. A novel technique for the prophylactic plating of the osteocutaneous radial forearm flap donor site.
Karamanoukian R; Gupta R; Evans GR
Ann Plast Surg; 2006 Feb; 56(2):200-4. PubMed ID: 16432333
[TBL] [Abstract][Full Text] [Related]
13. The effect of distal radius translation in the coronal plane on forearm rotation: a cadaveric study of distal radius fractures.
Hepper CT; Tsai MA; Parks BG; Dubin NH; Means KR
J Hand Surg Am; 2014 Apr; 39(4):651-5. PubMed ID: 24576752
[TBL] [Abstract][Full Text] [Related]
14. The effect of multiplanar distal radius fractures on forearm rotation: in vitro biomechanical study.
Fraser GS; Ferreira LM; Johnson JA; King GJ
J Hand Surg Am; 2009; 34(5):838-48. PubMed ID: 19410987
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical stability of a volar locking-screw plate versus fragment-specific fixation in a distal radius fracture model.
Cooper EO; Segalman KA; Parks BG; Sharma KM; Nguyen A
Am J Orthop (Belle Mead NJ); 2007 Apr; 36(4):E46-9. PubMed ID: 17703264
[TBL] [Abstract][Full Text] [Related]
16. Comparison of three different plating techniques for the dorsum of the distal radius: a biomechanical study.
Peine R; Rikli DA; Hoffmann R; Duda G; Regazzoni P
J Hand Surg Am; 2000 Jan; 25(1):29-33. PubMed ID: 10642470
[TBL] [Abstract][Full Text] [Related]
17. The hairless osteotomized radial forearm flap.
Moore MH; Sinclair SW; Blake GB
Plast Reconstr Surg; 1985 Aug; 76(2):301-6. PubMed ID: 4023103
[TBL] [Abstract][Full Text] [Related]
18. The effect of delayed internal fixation on healing of the osteotomized dog radius.
Coutts RD; Woo SL; Boyer J; Doty D; Gonsalves M; Amiel D; Akeson WH
Clin Orthop Relat Res; 1982 Mar; (163):254-60. PubMed ID: 7067260
[TBL] [Abstract][Full Text] [Related]
19. Outcomes of the osteocutaneous radial forearm free flap for mandibular reconstruction.
Arganbright JM; Tsue TT; Girod DA; Militsakh ON; Sykes KJ; Markey J; Shnayder Y
JAMA Otolaryngol Head Neck Surg; 2013 Feb; 139(2):168-72. PubMed ID: 23429948
[TBL] [Abstract][Full Text] [Related]
20. [Mechanical strain in the forearm bones].
Opitz A
Wien Klin Wochenschr Suppl; 1983; 141():1-27. PubMed ID: 6579803
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]