These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
258 related articles for article (PubMed ID: 23024054)
21. The Relation Between Optical Coherence Tomography-Detected Layered Pattern and Acute Side Branch Occlusion after Provisional Stenting of Coronary Bifurcation Lesions. Cao Y; Mintz GS; Matsumura M; Zhang W; Lin Y; Wang X; Fujino A; Lee T; Murai T; Hoshino M; Usui E; Kanaji Y; Yonetsu T; Kakuta T; Maehara A Cardiovasc Revasc Med; 2019 Nov; 20(11):1007-1013. PubMed ID: 30683562 [TBL] [Abstract][Full Text] [Related]
22. Predictors of stent strut malapposition in calcified vessels using frequency-domain optical coherence tomography. Lindsay AC; Paulo M; Kadriye K; Tejeiro R; Alegría-Barrero E; Chan PH; Foin N; Syrseloudis D; Di Mario C J Invasive Cardiol; 2013 Sep; 25(9):429-34. PubMed ID: 23995714 [TBL] [Abstract][Full Text] [Related]
24. Optical coherence tomography (OCT) strut-level analysis of drug-eluting stents (DES) in human coronary bifurcations. Kyono H; Guagliumi G; Sirbu V; Rosenthal N; Tahara S; Musumeci G; Trivisonno A; Bezerra HG; Costa MA EuroIntervention; 2010 May; 6(1):69-77. PubMed ID: 20542800 [TBL] [Abstract][Full Text] [Related]
25. Optical coherence tomography assessment of a new dedicated bifurcation stent. Tyczynski P; Ferrante G; Kukreja N; Moreno-Ambroj C; Barlis P; Ramasami N; De Silva R; Beatt K; Di Mario C EuroIntervention; 2009 Nov; 5(5):544-51. PubMed ID: 20142174 [TBL] [Abstract][Full Text] [Related]
26. Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial. Kim JS; Jang IK; Fan C; Kim TH; Kim JS; Park SM; Choi EY; Lee SH; Ko YG; Choi D; Hong MK; Jang Y JACC Cardiovasc Interv; 2009 Dec; 2(12):1240-7. PubMed ID: 20129551 [TBL] [Abstract][Full Text] [Related]
30. Feasibility and usefulness of three-dimensional optical coherence tomography guidance for optimal side branch treatment in coronary bifurcation stenting. Nagoshi R; Okamura T; Murasato Y; Fujimura T; Yamawaki M; Ono S; Serikawa T; Hikichi Y; Nakao F; Sakamoto T; Shinke T; Kijima Y; Kozuki A; Shibata H; Shite J Int J Cardiol; 2018 Jan; 250():270-274. PubMed ID: 29030141 [TBL] [Abstract][Full Text] [Related]
31. Serial intravascular ultrasound analysis of complex bifurcation coronary lesions treated with the Tryton Bifurcation Stent in conjunction with an everolimus-eluting stent: IUVANT (Intravascular Ultrasound Evaluation of Tryton Stent) study. Bartorelli AL; Trabattoni D; Almonacid A; Fabbiocchi F; Montorsi P; Galli S; Grancini L; Ravagnani P; Mintz GS; Kaplan AV; Popma JJ; Maehara A Catheter Cardiovasc Interv; 2015 Mar; 85(4):544-53. PubMed ID: 25115944 [TBL] [Abstract][Full Text] [Related]
32. Optical coherence tomography guidance for the management of angiographically intermediate left main bifurcation lesions: Early clinical experience. Dato I; Burzotta F; Trani C; Romano A; Paraggio L; Aurigemma C; Porto I; Leone AM; Niccoli G; Crea F Int J Cardiol; 2017 Dec; 248():108-113. PubMed ID: 28709701 [TBL] [Abstract][Full Text] [Related]
33. Serial intravascular ultrasound analysis of the main and side branches in bifurcation lesions treated with the T-stenting technique. Hahn JY; Song YB; Lee SY; Choi JH; Choi SH; Kim DK; Lee SH; Gwon HC J Am Coll Cardiol; 2009 Jul; 54(2):110-7. PubMed ID: 19573726 [TBL] [Abstract][Full Text] [Related]
34. Final proximal post-dilatation is necessary after kissing balloon in bifurcation stenting. Foin N; Secco GG; Ghilencea L; Krams R; Di Mario C EuroIntervention; 2011 Sep; 7(5):597-604. PubMed ID: 21930464 [TBL] [Abstract][Full Text] [Related]
35. Angiographic and clinical outcomes after implantation of drug eluting stents in bifurcation lesions with crush or kissing stent technique. Cheema AN; Jolly SS; Burstein JM; Sharieff W; Mohammad A; Yeoh E; Mancini GB; Cantor WJ; Kutryk MJ; Strauss BH; Chisholm RJ J Interv Cardiol; 2013 Apr; 26(2):145-52. PubMed ID: 23406435 [TBL] [Abstract][Full Text] [Related]
36. Three-Dimensional Optical Coherence Tomographic Analysis of Eccentric Morphology of the Jailed Side-Branch Ostium in Coronary Bifurcation Lesions. Cho S; Kim JS; Ha J; Shin DH; Kim BK; Ko YG; Choi D; Jang Y; Hong MK Can J Cardiol; 2016 Feb; 32(2):234-9. PubMed ID: 26341304 [TBL] [Abstract][Full Text] [Related]
37. Procedural findings and early healing response after implantation of a self-apposing bioresorbable scaffold in coronary bifurcation lesions. Holck EN; Fox-Maule C; Barkholt TØ; Jakobsen L; Tu S; Maeng M; Dijkstra J; Christiansen EH; Holm NR Int J Cardiovasc Imaging; 2019 Jul; 35(7):1199-1210. PubMed ID: 31053981 [TBL] [Abstract][Full Text] [Related]
38. Clinical and angiographic predictors of major side branch occlusion after main vessel stenting in coronary bifurcation lesions. Zhang D; Xu B; Yin D; Li YP; He Y; You SJ; Qiao SB; Wu YJ; Yan HB; Yang YJ; Gao RL; Dou KF Chin Med J (Engl); 2015 Jun; 128(11):1471-8. PubMed ID: 26021503 [TBL] [Abstract][Full Text] [Related]
39. Dedicated bifurcation stents - Mechanistic, hardware, and technical aspects. Mishra S Indian Heart J; 2016; 68(6):841-850. PubMed ID: 27931557 [TBL] [Abstract][Full Text] [Related]
40. The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Tanigawa J; Barlis P; Dimopoulos K; Dalby M; Moore P; Di Mario C Int J Cardiol; 2009 May; 134(2):180-8. PubMed ID: 18775576 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]