These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 23025621)

  • 1. The resistive bolometer for radiated power measurement on EAST.
    Duan YM; Hu LQ; Mao ST; Chen KY; Lin SY;
    Rev Sci Instrum; 2012 Sep; 83(9):093501. PubMed ID: 23025621
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Operation of bolometer system using Pt foil on SiN substrate detector for EAST tokamak.
    Duan YM; Mao ST; Hu LQ; Xu P; Xu LQ; Zhang JZ; Lin SY
    Rev Sci Instrum; 2016 Nov; 87(11):11D434. PubMed ID: 27910562
    [TBL] [Abstract][Full Text] [Related]  

  • 3. First results of the resistive bolometers on KSTAR.
    Seo D; Peterson BJ; Lee SH
    Rev Sci Instrum; 2010 Oct; 81(10):10E128. PubMed ID: 21033992
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Broad-band efficiency calibration of ITER bolometer prototypes using Pt absorbers on SiN membranes.
    Meister H; Willmeroth M; Zhang D; Gottwald A; Krumrey M; Scholze F
    Rev Sci Instrum; 2013 Dec; 84(12):123501. PubMed ID: 24387428
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optimization of a bolometer detector for ITER based on Pt absorber on SiN membrane.
    Meister H; Eich T; Endstrasser N; Giannone L; Kannamüller M; Kling A; Koll J; Trautmann T; ; Detemple P; Schmitt S
    Rev Sci Instrum; 2010 Oct; 81(10):10E132. PubMed ID: 21061487
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new absolute extreme ultraviolet image system designed for studying the radiated power of the Joint Texas Experimental Tokamak discharges.
    Zhang J; Zhuang G; Wang ZJ; Ding YH; Zhang XQ; Tang YJ
    Rev Sci Instrum; 2010 Jul; 81(7):073509. PubMed ID: 20687724
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Conceptual design for resistive bolometer system with multiple apertures for measurement of total radiated power in JT-60SA.
    Sano R; Fukumoto M; Nakano T; Oyama N
    Rev Sci Instrum; 2018 Oct; 89(10):10E104. PubMed ID: 30399971
    [TBL] [Abstract][Full Text] [Related]  

  • 8. New design techniques of resistive bolometer system for analysis of total radiated power.
    Sano R; Fukumoto M; Nakano T; Oyama N
    Rev Sci Instrum; 2018 Aug; 89(8):083501. PubMed ID: 30184678
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experimental tests of an infrared video bolometer on Alcator C-Mod.
    Reinke ML; Terry JL; van Eden GG; Peterson BJ; Mukai K; Gray TK; Stratton BC
    Rev Sci Instrum; 2018 Oct; 89(10):103507. PubMed ID: 30399930
    [TBL] [Abstract][Full Text] [Related]  

  • 10. First results obtained from the soft x-ray pulse height analyzer on experimental advanced superconducting tokamak.
    Xu P; Lin SY; Hu LQ; Duan YM; Zhang JZ; Chen KY; Zhong GQ
    Rev Sci Instrum; 2010 Jun; 81(6):063501. PubMed ID: 20590235
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Two dimensional radiated power diagnostics on Alcator C-Mod.
    Reinke ML; Hutchinson IH
    Rev Sci Instrum; 2008 Oct; 79(10):10F306. PubMed ID: 19044619
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development of plasma bolometers using fiber-optic temperature sensors.
    Reinke ML; Han M; Liu G; van Eden GG; Evenblij R; Haverdings M; Stratton BC
    Rev Sci Instrum; 2016 Nov; 87(11):11E708. PubMed ID: 27910644
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of a weighted sum estimate of the total radiated power from large helical device plasma.
    van de Giessen PL; Kawamura G; Borling S; Mukai K; Peterson BJ
    Rev Sci Instrum; 2021 Mar; 92(3):033518. PubMed ID: 33820070
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Design and characterization of a prototype divertor viewing infrared video bolometer for NSTX-U.
    van Eden GG; Reinke ML; Peterson BJ; Gray TK; Delgado-Aparicio LF; Jaworski MA; Lore J; Mukai K; Sano R; Pandya SN; Morgan TW
    Rev Sci Instrum; 2016 Nov; 87(11):11D402. PubMed ID: 27910411
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reliability issues for a bolometer detector for ITER at high operating temperatures.
    Meister H; Kannamüller M; Koll J; Pathak A; Penzel F; Trautmann T; Detemple P; Schmitt S; Langer H
    Rev Sci Instrum; 2012 Oct; 83(10):10D724. PubMed ID: 23126898
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Overview and first measurements of the MAST Upgrade bolometer diagnostic.
    Lovell J; Reinke ML; Field AR; Lomanowski BA;
    Rev Sci Instrum; 2023 Feb; 94(2):023509. PubMed ID: 36859004
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Generic approach to assess the measuring performance of total-radiated power quantities by multi-channel resistive bolometer diagnostics on fusion experiments.
    Ingesson LC; Doblas A; Gandhi A; Jahanbakhsh S; Meister H
    Rev Sci Instrum; 2024 Jan; 95(1):. PubMed ID: 38214589
    [TBL] [Abstract][Full Text] [Related]  

  • 18. First demonstration of a fiber optic bolometer on a tokamak plasma (invited).
    Lee S; Shafer M; Reinke M; Uddin N; Sheng Q; Han M; Donovan D; O'Neill R
    Rev Sci Instrum; 2022 Dec; 93(12):123515. PubMed ID: 36586957
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of frequency modulation reflectometer for Korea Superconducting Tokamak Advanced Research tokamak.
    Seo SH; Park J; Wi HM; Lee WR; Kim HS; Lee TG; Kim YS; Kang JS; Bog MG; Yokota Y; Mase A
    Rev Sci Instrum; 2013 Aug; 84(8):084702. PubMed ID: 24007083
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Minimum Fisher regularization of image reconstruction for infrared imaging bolometer on HL-2A.
    Gao JM; Liu Y; Li W; Lu J; Dong YB; Xia ZW; Yi P; Yang QW
    Rev Sci Instrum; 2013 Sep; 84(9):093503. PubMed ID: 24089825
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.