These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

195 related articles for article (PubMed ID: 23026855)

  • 21. A sensitive and selective colorimetric method for detection of copper ions based on anti-aggregation of unmodified gold nanoparticles.
    Hormozi-Nezhad MR; Abbasi-Moayed S
    Talanta; 2014 Nov; 129():227-32. PubMed ID: 25127588
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A surface enhanced Raman scattering quantitative analytical platform for detection of trace Cu coupled the catalytic reaction and gold nanoparticle aggregation with label-free Victoria blue B molecular probe.
    Li C; Ouyang H; Tang X; Wen G; Liang A; Jiang Z
    Biosens Bioelectron; 2017 Jan; 87():888-893. PubMed ID: 27662583
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Solid phase extraction of trace amounts of Ag, Cd, Cu, and Zn in environmental samples using magnetic nanoparticles coated by 3-(trimethoxysilyl)-1-propantiol and modified with 2-amino-5-mercapto-1,3,4-thiadiazole and their determination by ICP-OES.
    Mashhadizadeh MH; Karami Z
    J Hazard Mater; 2011 Jun; 190(1-3):1023-9. PubMed ID: 21561711
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Colorimetric detection of trace copper ions based on catalytic leaching of silver-coated gold nanoparticles.
    Lou T; Chen L; Chen Z; Wang Y; Chen L; Li J
    ACS Appl Mater Interfaces; 2011 Nov; 3(11):4215-20. PubMed ID: 21970438
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Controlled fabrication of polyethylenimine-functionalized magnetic nanoparticles for the sequestration and quantification of free Cu2+.
    Goon IY; Zhang C; Lim M; Gooding JJ; Amal R
    Langmuir; 2010 Jul; 26(14):12247-52. PubMed ID: 20527930
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Core-shell Fe
    Yavuz E; Tokalıoğlu Ş; Patat Ş
    Food Chem; 2018 Oct; 263():232-239. PubMed ID: 29784312
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Separation/preconcentration of trace amounts of Cr, Cu and Pb in environmental samples by magnetic solid-phase extraction with Bismuthiol-II-immobilized magnetic nanoparticles and their determination by ICP-OES.
    Suleiman JS; Hu B; Peng H; Huang C
    Talanta; 2009 Mar; 77(5):1579-83. PubMed ID: 19159767
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Colorimetric detection of mercury, lead and copper ions simultaneously using protein-functionalized gold nanoparticles.
    Guo Y; Wang Z; Qu W; Shao H; Jiang X
    Biosens Bioelectron; 2011 Jun; 26(10):4064-9. PubMed ID: 21543219
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Ligand-free gold nanoparticles as colorimetric probes for the non-destructive determination of total dithiocarbamate pesticides after solid phase extraction.
    Giannoulis KM; Giokas DL; Tsogas GZ; Vlessidis AG
    Talanta; 2014 Feb; 119():276-83. PubMed ID: 24401415
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Synthesis and application of surface-imprinted activated carbon sorbent for solid-phase extraction and determination of copper (II).
    Li Z; Li J; Wang Y; Wei Y
    Spectrochim Acta A Mol Biomol Spectrosc; 2014 Jan; 117():422-7. PubMed ID: 24012981
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Determination of triazine herbicides in environmental water samples by high-performance liquid chromatography using graphene-coated magnetic nanoparticles as adsorbent.
    Zhao G; Song S; Wang C; Wu Q; Wang Z
    Anal Chim Acta; 2011 Dec; 708(1-2):155-9. PubMed ID: 22093359
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A ligation DNAzyme-induced magnetic nanoparticles assembly for ultrasensitive detection of copper ions.
    Yin H; Kuang H; Liu L; Xu L; Ma W; Wang L; Xu C
    ACS Appl Mater Interfaces; 2014 Apr; 6(7):4752-7. PubMed ID: 24611502
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Preparation and characterization of magnetic nanocomposite of Schiff base/silica/magnetite as a preconcentration phase for the trace determination of heavy metal ions in water, food and biological samples using atomic absorption spectrometry.
    Bagheri H; Afkhami A; Saber-Tehrani M; Khoshsafar H
    Talanta; 2012 Aug; 97():87-95. PubMed ID: 22841051
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Highly sensitive visual detection of copper (II) using water-soluble azide-functionalized gold nanoparticles and silver enhancement.
    Zhang Z; Li W; Zhao Q; Cheng M; Xu L; Fang X
    Biosens Bioelectron; 2014 Sep; 59():40-4. PubMed ID: 24690560
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Chemically modified activated carbon with 1-acylthiosemicarbazide for selective solid-phase extraction and preconcentration of trace Cu(II), Hg(II) and Pb(II) from water samples.
    Gao R; Hu Z; Chang X; He Q; Zhang L; Tu Z; Shi J
    J Hazard Mater; 2009 Dec; 172(1):324-9. PubMed ID: 19643535
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Selective and eco-friendly method for determination of mercury(II) ions in aqueous samples using an on-line AuNPs-PDMS composite microfluidic device/ICP-MS system.
    Hsu KC; Lee CF; Tseng WC; Chao YY; Huang YL
    Talanta; 2014 Oct; 128():408-13. PubMed ID: 25059179
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A sensitive plasmonic copper(II) sensor based on gold nanoparticles deposited on ITO glass substrate.
    Ding L; Gao Y; Di J
    Biosens Bioelectron; 2016 Sep; 83():9-14. PubMed ID: 27093484
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Gold nanoparticle-sensitized quartz crystal microbalance sensor for rapid and highly selective determination of Cu(II) ions.
    Jin Y; Huang Y; Liu G; Zhao R
    Analyst; 2013 Sep; 138(18):5479-85. PubMed ID: 23888301
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The use of graphene-based magnetic nanoparticles as adsorbent for the extraction of triazole fungicides from environmental water.
    Wang W; Ma X; Wu Q; Wang C; Zang X; Wang Z
    J Sep Sci; 2012 Sep; 35(17):2266-72. PubMed ID: 22715113
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Europium(III) complex-functionalized magnetic nanoparticle as a chemosensor for ultrasensitive detection and removal of copper(II) from aqueous solution.
    Liu J; Zuo W; Zhang W; Liu J; Wang Z; Yang Z; Wang B
    Nanoscale; 2014 Oct; 6(19):11473-8. PubMed ID: 25155471
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.