155 related articles for article (PubMed ID: 23032437)
1. Genipin crosslinking elevates the strength of electrochemically aligned collagen to the level of tendons.
Alfredo Uquillas J; Kishore V; Akkus O
J Mech Behav Biomed Mater; 2012 Nov; 15():176-89. PubMed ID: 23032437
[TBL] [Abstract][Full Text] [Related]
2. Bioglass incorporation improves mechanical properties and enhances cell-mediated mineralization on electrochemically aligned collagen threads.
Nijsure MP; Pastakia M; Spano J; Fenn MB; Kishore V
J Biomed Mater Res A; 2017 Sep; 105(9):2429-2440. PubMed ID: 28470671
[TBL] [Abstract][Full Text] [Related]
3. Tenogenic differentiation of human MSCs induced by the topography of electrochemically aligned collagen threads.
Kishore V; Bullock W; Sun X; Van Dyke WS; Akkus O
Biomaterials; 2012 Mar; 33(7):2137-44. PubMed ID: 22177622
[TBL] [Abstract][Full Text] [Related]
4. Effects of phosphate-buffered saline concentration and incubation time on the mechanical and structural properties of electrochemically aligned collagen threads.
Uquillas JA; Kishore V; Akkus O
Biomed Mater; 2011 Jun; 6(3):035008. PubMed ID: 21540522
[TBL] [Abstract][Full Text] [Related]
5. Incorporation of a decorin biomimetic enhances the mechanical properties of electrochemically aligned collagen threads.
Kishore V; Paderi JE; Akkus A; Smith KM; Balachandran D; Beaudoin S; Panitch A; Akkus O
Acta Biomater; 2011 Jun; 7(6):2428-36. PubMed ID: 21356334
[TBL] [Abstract][Full Text] [Related]
6. In vitro evaluation of Ficoll-enriched and genipin-stabilised collagen scaffolds.
Satyam A; Subramanian GS; Raghunath M; Pandit A; Zeugolis DI
J Tissue Eng Regen Med; 2014 Mar; 8(3):233-41. PubMed ID: 22552937
[TBL] [Abstract][Full Text] [Related]
7. Biologically active and biomimetic dual gelatin scaffolds for tissue engineering.
Sánchez P; Pedraz JL; Orive G
Int J Biol Macromol; 2017 May; 98():486-494. PubMed ID: 28185928
[TBL] [Abstract][Full Text] [Related]
8. Biocompatible fibrous networks of cellulose nanofibres and collagen crosslinked using genipin: potential as artificial ligament/tendons.
Mathew AP; Oksman K; Pierron D; Harmand MF
Macromol Biosci; 2013 Mar; 13(3):289-98. PubMed ID: 23225770
[TBL] [Abstract][Full Text] [Related]
9. In vitro characterization of electrochemically compacted collagen matrices for corneal applications.
Kishore V; Iyer R; Frandsen A; Nguyen TU
Biomed Mater; 2016 Oct; 11(5):055008. PubMed ID: 27710923
[TBL] [Abstract][Full Text] [Related]
10. In vivo response to electrochemically aligned collagen bioscaffolds.
Kishore V; Uquillas JA; Dubikovsky A; Alshehabat MA; Snyder PW; Breur GJ; Akkus O
J Biomed Mater Res B Appl Biomater; 2012 Feb; 100(2):400-8. PubMed ID: 22179969
[TBL] [Abstract][Full Text] [Related]
11. Genipin-induced changes in collagen gels: correlation of mechanical properties to fluorescence.
Sundararaghavan HG; Monteiro GA; Lapin NA; Chabal YJ; Miksan JR; Shreiber DI
J Biomed Mater Res A; 2008 Nov; 87(2):308-20. PubMed ID: 18181104
[TBL] [Abstract][Full Text] [Related]
12. Genipin-cross-linked electrospun collagen fibers.
Mekhail M; Wong KK; Padavan DT; Wu Y; O'Gorman DB; Wan W
J Biomater Sci Polym Ed; 2011; 22(17):2241-59. PubMed ID: 21083975
[TBL] [Abstract][Full Text] [Related]
13. An investigation of common crosslinking agents on the stability of electrospun collagen scaffolds.
Huang GP; Shanmugasundaram S; Masih P; Pandya D; Amara S; Collins G; Arinzeh TL
J Biomed Mater Res A; 2015 Feb; 103(2):762-71. PubMed ID: 24828818
[TBL] [Abstract][Full Text] [Related]
14. Tuning the Mechanical and Geometric Properties of Electrochemically Aligned Collagen Threads Toward Applications in Biohybrid Robotics.
Sun W; Paulovich J; Webster-Wood V
J Biomech Eng; 2021 May; 143(5):. PubMed ID: 33513225
[TBL] [Abstract][Full Text] [Related]
15. Preparation and characterization of genipin-crosslinked rat acellular spinal cord scaffolds.
Jiang T; Ren XJ; Tang JL; Yin H; Wang KJ; Zhou CL
Mater Sci Eng C Mater Biol Appl; 2013 Aug; 33(6):3514-21. PubMed ID: 23706241
[TBL] [Abstract][Full Text] [Related]
16. Comparison of morphology, orientation, and migration of tendon derived fibroblasts and bone marrow stromal cells on electrochemically aligned collagen constructs.
Gurkan UA; Cheng X; Kishore V; Uquillas JA; Akkus O
J Biomed Mater Res A; 2010 Sep; 94(4):1070-9. PubMed ID: 20694974
[TBL] [Abstract][Full Text] [Related]
17. Assessing the effects of intratendinous genipin injections: Mechanical augmentation and spatial distribution in an ex vivo degenerative tendon model.
Tondelli T; Götschi T; Camenzind RS; Snedeker JG
PLoS One; 2020; 15(4):e0231619. PubMed ID: 32294117
[TBL] [Abstract][Full Text] [Related]
18. The effects of different cross-linking conditions on collagen-based nanocomposite scaffolds-an in vitro evaluation using mesenchymal stem cells.
Suchý T; Šupová M; Sauerová P; Verdánová M; Sucharda Z; Rýglová Š; Žaloudková M; Sedláček R; Kalbáčová MH
Biomed Mater; 2015 Nov; 10(6):065008. PubMed ID: 26586611
[TBL] [Abstract][Full Text] [Related]
19. Collagen-gelatin-genipin-hydroxyapatite composite scaffolds colonized by human primary osteoblasts are suitable for bone tissue engineering applications: in vitro evidences.
Vozzi G; Corallo C; Carta S; Fortina M; Gattazzo F; Galletti M; Giordano N
J Biomed Mater Res A; 2014 May; 102(5):1415-21. PubMed ID: 23775901
[TBL] [Abstract][Full Text] [Related]
20. Is quercetin an alternative natural crosslinking agent to genipin for long-term dermal scaffolds implantation?
Greco KV; Francis L; Huang H; Ploeg R; Boccaccini AR; Ansari T
J Tissue Eng Regen Med; 2018 Mar; 12(3):e1716-e1724. PubMed ID: 27717209
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]