BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 23035773)

  • 1. ECG criteria for accurate localization of left anterolateral and posterolateral accessory pathways.
    Moss JD; Gerstenfeld EP; Deo R; Hutchinson MD; Callans DJ; Marchlinski FE; Dixit S
    Pacing Clin Electrophysiol; 2012 Dec; 35(12):1444-50. PubMed ID: 23035773
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Positive QRS complex in limb lead 2 with negative QRS in lead 3 on surface electrocardiogram: A novel predictor for anterior location of right-sided accessory pathways (10-1 o'clock on tricuspid annulus).
    Bera D; Mukherjee SS; Majumder S; Sikdar S; Dasgupta K; Kar A; Kathuria S; Sarkar R
    J Cardiovasc Electrophysiol; 2022 May; 33(5):953-961. PubMed ID: 35175685
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-Catheter Technique for Ablation of Left-Sided Accessory Pathways in Wolff-Parkinson-White is Less Expensive and Equally Successful When Compared to a Five-Catheter Technique.
    Capone CA; Ceresnak SR; Nappo L; Gates GJ; Schechter CB; Pass RH
    Pacing Clin Electrophysiol; 2015 Dec; 38(12):1405-11. PubMed ID: 26400468
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Non-contact mapping system accurately localizes right-sided accessory pathways in type B Wolff-Parkinson-White syndrome.
    Nishida T; Nakajima T; Kaitani K; Takitsume A; Soeda T; Okayama S; Somekawa S; Takeda Y; Ishigami K; Kawata H; Kawakami R; Horii M; Uemura S; Saito Y
    Europace; 2012 May; 14(5):752-60. PubMed ID: 22135318
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Increased preexcitation on electrocardiography improves accuracy of algorithms for accessory pathway localization in Wolff-Parkinson-White syndrome.
    Moskal P; Bednarski A; Kiełbasa G; Czarnecka D; Jastrzębski M
    Kardiol Pol; 2020 Jun; 78(6):567-573. PubMed ID: 32438794
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Delta wave notching time is associated with accessory pathway localization in patients with Wolff-Parkinson-White syndrome.
    Icen YK; Donmez Y; Koca H; Kaypaklı O; Koc M
    J Interv Card Electrophysiol; 2018 Oct; 53(1):73-79. PubMed ID: 30014371
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Vectorcardiography shows cardiac memory and repolarization heterogeneity after ablation of accessory pathways not apparent on ECG.
    Wecke L; Poçi D; Schwieler J; Johansson B; Edvardsson N; Lundahl G; Bergfeldt L
    Int J Cardiol; 2013 Jun; 166(1):152-7. PubMed ID: 22078977
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Is the 12-lead electrocardiogram during antidromic circus movement tachycardia helpful in predicting the ablation site in atriofascicular pathways?
    Sternick EB; Lokhandwala Y; Bohora S; Timmermans C; Martins PR; Dias LV; Correia FS; Wellens HJ
    Europace; 2014 Nov; 16(11):1610-8. PubMed ID: 24681762
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Localization of Accessory Pathways in Pediatric Patients With Wolff-Parkinson-White Syndrome Using 3D-Rendered Electromechanical Wave Imaging.
    Melki L; Grubb CS; Weber R; Nauleau P; Garan H; Wan E; Silver ES; Liberman L; Konofagou EE
    JACC Clin Electrophysiol; 2019 Apr; 5(4):427-437. PubMed ID: 31000096
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Atrioventricular reciprocating tachycardia with QRS type left branch block in patients undergoing radiofrequency catheter ablation: analysis of the substrate and mechanism of tachycardia].
    De Ponti R; Storti C; Salerno-Uriarte JA; Stanke A; Longobardi M; Ferrari AA; Zardini M
    G Ital Cardiol; 1994 Jun; 24(6):707-21. PubMed ID: 8088470
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ablation of left-sided accessory pathways with atrial insertion away from the mitral annulus using an electroanatomical mapping system.
    Long DY; Dong JZ; Sang CH; Jiang CX; Tang RB; Yan Q; Yu RH; Li SN; Salim M; Yao Y; Lin T; Ning M; Ma CS
    J Cardiovasc Electrophysiol; 2013 Jul; 24(7):788-92. PubMed ID: 23581615
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A case for ambidextrous doctors.
    Duthoit G; Frank R; Aouate P; Lacotte J; Hidden-Lucet F
    Europace; 2010 Nov; 12(11):1645-7. PubMed ID: 20682555
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ablation of a left lateral accessory pathway in a patient with dextroposition of the heart.
    Baranchuk A; Somani R; Simpson CS; Michael KA; Redfearn DP
    Cardiol J; 2012; 19(4):439-40. PubMed ID: 22825909
    [No Abstract]   [Full Text] [Related]  

  • 14. Noninvasive Localization of Accessory Pathways in Wolff-Parkinson-White Syndrome by Three-Dimensional Speckle Tracking Echocardiography.
    Ishizu T; Seo Y; Igarashi M; Sekiguchi Y; Machino-Ohtsuka T; Ogawa K; Kuroki K; Yamamoto M; Nogami A; Kawakami Y; Aonuma K
    Circ Cardiovasc Imaging; 2016 Jun; 9(6):. PubMed ID: 27307551
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrocardiographic and electrophysiologic predictors of successful ablation site in patients with manifest posteroseptal accessory pathway.
    Haghjoo M; Mahmoodi E; Fazelifar AF; Alizadeh A; Hashemi MJ; Emkanjoo Z; Sadr-Ameli MA
    Pacing Clin Electrophysiol; 2008 Jan; 31(1):103-11. PubMed ID: 18181918
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accessory pathway localization by QRS polarity in children with Wolff-Parkinson-White syndrome.
    Boersma L; García-Moran E; Mont L; Brugada J
    J Cardiovasc Electrophysiol; 2002 Dec; 13(12):1222-6. PubMed ID: 12521337
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Localization of accessory pathways in the Wolff-Parkinson-White pattern--physician versus computer interpretation of the same algorithm.
    McGavigan AD; Clark E; Quinn FR; Rankin AC; Macfarlane PW
    Pacing Clin Electrophysiol; 2007 Aug; 30(8):998-1002. PubMed ID: 17669083
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Limited fluoroscopy catheter ablation of accessory pathways in children.
    Swissa M; Birk E; Dagan T; Abby Naimer S; Fogelman M; Einbinder T; Bruckheimer E; Fogelman R
    J Cardiol; 2017 Oct; 70(4):382-386. PubMed ID: 28274505
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Zero-Fluoroscopy Ablation of Accessory Pathways in Children and Adolescents: CARTO3 Electroanatomic Mapping Combined with RF and Cryoenergy.
    Scaglione M; Ebrille E; Caponi D; Siboldi A; Bertero G; Di Donna P; Gabbarini F; Raimondo C; Di Clemente F; Ferrato P; Marasini M; Gaita F
    Pacing Clin Electrophysiol; 2015 Jun; 38(6):675-81. PubMed ID: 25727697
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of the Electrocardiogram in Localizing the Accessory Pathway in Patients with Wolff-Parkinson-White Pattern.
    Teixeira CM; Pereira TA; Lebreiro AM; Carvalho SA
    Arq Bras Cardiol; 2016 Oct; 107(4):331-338. PubMed ID: 27627222
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.