These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

162 related articles for article (PubMed ID: 23039654)

  • 21. Determination of the modulation transfer function using the edge method: influence of scattered radiation.
    Neitzel U; Buhr E; Hilgers G; Granfors PR
    Med Phys; 2004 Dec; 31(12):3485-91. PubMed ID: 15651631
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Measuring the presampled MTF from a reduced number of flat-field images using the Noise Response (NR) method.
    Kuhls-Gilcrist A; Jain A; Bednarek DR; Rudin S
    Proc SPIE Int Soc Opt Eng; 2011 Mar; 7961(79614G):. PubMed ID: 21731401
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Use of a slit camera for MTF measurements.
    Bradford CD; Peppler WW; Waidelich JM
    Med Phys; 1999 Nov; 26(11):2286-94. PubMed ID: 10587209
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A comprehensive model for quantum noise characterization in digital mammography.
    Monnin P; Bosmans H; Verdun FR; Marshall NW
    Phys Med Biol; 2016 Mar; 61(5):2083-108. PubMed ID: 26895467
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A method for the determination of the two-dimensional MTF of digital radiography systems using only the noise response.
    Kuhls-Gilcrist A; Bednarek DR; Rudin S
    Proc SPIE Int Soc Opt Eng; 2010 Mar; 7622(76224W):76224W-76244W9. PubMed ID: 21170177
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Comparison of noise characteristics of direct and indirect conversion flat panel detectors].
    Murai M; Kishimoto K; Tanaka K; Oota K; Ienaga A
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2010 Nov; 66(11):1443-8. PubMed ID: 21099174
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Application of a variable filter for presampled modulation transfer function analysis with the edge method.
    Higashide R; Ichikawa K; Kunitomo H; Ohashi K
    Radiol Phys Technol; 2015 Jul; 8(2):320-30. PubMed ID: 26088943
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Analysis of the precision of modulation transfer function measurements with a circular edge: influence of object circularity.
    Maruyama S
    J Med Imaging (Bellingham); 2023 Jul; 10(4):043503. PubMed ID: 37654978
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Measurement of the modulation transfer function of digital X-ray detectors with an opaque edge-test device.
    Illers H; Buhr E; Günther-Kohfahl S; Neitzel U
    Radiat Prot Dosimetry; 2005; 114(1-3):214-9. PubMed ID: 15933111
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Technical Note: Impact on detective quantum efficiency of edge angle determination method by International Electrotechnical Commission methodology for cardiac x-ray image detectors.
    Gislason-Lee AJ; Tunstall CM; Kengyelics SK; Cowen AR; Davies AG
    Med Phys; 2015 Aug; 42(8):4423-7. PubMed ID: 26233172
    [TBL] [Abstract][Full Text] [Related]  

  • 31. An experimental comparison of flat-panel detector performance for direct and indirect systems (initial experiences and physical evaluation).
    Gomi T; Koshida K; Miyati T; Miyagawa J; Hirano H
    J Digit Imaging; 2006 Dec; 19(4):362-70. PubMed ID: 16763929
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Oblique reconstructions in tomosynthesis. I. Linear systems theory.
    Acciavatti RJ; Maidment AD
    Med Phys; 2013 Nov; 40(11):111911. PubMed ID: 24320444
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Towards task-based assessment of CT performance: system and object MTF across different reconstruction algorithms.
    Richard S; Husarik DB; Yadava G; Murphy SN; Samei E
    Med Phys; 2012 Jul; 39(7):4115-22. PubMed ID: 22830744
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Determination of the two-dimensional detective quantum efficiency of a computed radiography system.
    Båth M; Håkansson M; Månsson LG
    Med Phys; 2003 Dec; 30(12):3172-82. PubMed ID: 14713084
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of noise on MTF calculations using different phantoms.
    González-López A
    Med Phys; 2018 May; 45(5):1889-1898. PubMed ID: 29500817
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Singular value description of a digital radiographic detector: theory and measurements.
    Kyprianou IS; Badano A; Gallas BD; Myers KJ
    Med Phys; 2008 Oct; 35(10):4744-56. PubMed ID: 18975719
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Simulation Analysis on the Performance of a Circular-Edge Technique in Measurements of the Modulation Transfer Function.
    Maruyama S
    J Med Phys; 2023; 48(1):90-97. PubMed ID: 37342601
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Monotone spline regression for accurate MTF measurement at low frequencies.
    Zhou Z; Gao F; Zhao H; Zhang L; Ren L; Li Z; Ghani MU; Liu H
    Opt Express; 2014 Sep; 22(19):22446-55. PubMed ID: 25321715
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The effects of scattered radiation from a semitransparent edge on MTF measurement: verification of several factors by Monte Carlo simulation.
    Maruyama S; Shimosegawa M
    Phys Eng Sci Med; 2020 Jun; 43(2):547-556. PubMed ID: 32524439
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Determining the MTF of medical imaging displays using edge techniques.
    Chawla AS; Roehrig H; Rodriguez JJ; Fan J
    J Digit Imaging; 2005 Dec; 18(4):296-310. PubMed ID: 16132485
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.