945 related articles for article (PubMed ID: 23040577)
1. Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve.
Urena M; Mok M; Serra V; Dumont E; Nombela-Franco L; DeLarochellière R; Doyle D; Igual A; Larose E; Amat-Santos I; Côté M; Cuéllar H; Pibarot P; de Jaegere P; Philippon F; Garcia del Blanco B; Rodés-Cabau J
J Am Coll Cardiol; 2012 Oct; 60(18):1743-52. PubMed ID: 23040577
[TBL] [Abstract][Full Text] [Related]
2. Impact of new-onset persistent left bundle branch block on late clinical outcomes in patients undergoing transcatheter aortic valve implantation with a balloon-expandable valve.
Urena M; Webb JG; Cheema A; Serra V; Toggweiler S; Barbanti M; Cheung A; Ye J; Dumont E; DeLarochellière R; Doyle D; Al Lawati HA; Peterson M; Chisholm R; Igual A; Ribeiro HB; Nombela-Franco L; Philippon F; Garcia Del Blanco B; Rodés-Cabau J
JACC Cardiovasc Interv; 2014 Feb; 7(2):128-136. PubMed ID: 24440024
[TBL] [Abstract][Full Text] [Related]
3. Conduction disturbances and permanent cardiac pacing after transcatheter implantation of the CoreValve aortic bioprosthesis: initial single centre experience.
Czerwińska K; Hryniewiecki T; Oręziak A; Dąbrowski M; Michałowska I; Witkowski A; Demkow M; Stępińska J; Orłowska Baranowska E; Rużyłło W
Kardiol Pol; 2012; 70(2):121-8. PubMed ID: 22427074
[TBL] [Abstract][Full Text] [Related]
4. The incidence of transcatheter aortic valve implantation-related heart block in self-expandable Medtronic CoreValve and balloon-expandable Edwards valves.
Liang M; Devlin G; Pasupati S
J Invasive Cardiol; 2012 Apr; 24(4):173-6. PubMed ID: 22477754
[TBL] [Abstract][Full Text] [Related]
5. Electrocardiographic changes and clinical outcomes after transapical aortic valve implantation.
Gutiérrez M; Rodés-Cabau J; Bagur R; Doyle D; DeLarochellière R; Bergeron S; Lemieux J; Villeneuve J; Côté M; Bertrand OF; Poirier P; Clavel MA; Pibarot P; Dumont E
Am Heart J; 2009 Aug; 158(2):302-8. PubMed ID: 19619709
[TBL] [Abstract][Full Text] [Related]
6. Occurrence, fate and consequences of ventricular conduction abnormalities after transcatheter aortic valve implantation.
Houthuizen P; van der Boon RM; Urena M; Van Mieghem N; Brueren GB; Poels TT; Van Garsse LA; Rodés-Cabau J; Prinzen FW; de Jaegere P
EuroIntervention; 2014 Feb; 9(10):1142-50. PubMed ID: 24273252
[TBL] [Abstract][Full Text] [Related]
7. Comparison of incidence and predictors of left bundle branch block after transcatheter aortic valve implantation using the CoreValve versus the Edwards valve.
Franzoni I; Latib A; Maisano F; Costopoulos C; Testa L; Figini F; Giannini F; Basavarajaiah S; Mussardo M; Slavich M; Taramasso M; Cioni M; Longoni M; Ferrarello S; Radinovic A; Sala S; Ajello S; Sticchi A; Giglio M; Agricola E; Chieffo A; Montorfano M; Alfieri O; Colombo A
Am J Cardiol; 2013 Aug; 112(4):554-9. PubMed ID: 23726173
[TBL] [Abstract][Full Text] [Related]
8. Clinical implications of new-onset left bundle branch block after transcatheter aortic valve replacement: analysis of the PARTNER experience.
Nazif TM; Williams MR; Hahn RT; Kapadia S; Babaliaros V; Rodés-Cabau J; Szeto WY; Jilaihawi H; Fearon WF; Dvir D; Dewey TM; Makkar RR; Xu K; Dizon JM; Smith CR; Leon MB; Kodali SK
Eur Heart J; 2014 Jun; 35(24):1599-607. PubMed ID: 24179072
[TBL] [Abstract][Full Text] [Related]
9. Need for permanent pacemaker as a complication of transcatheter aortic valve implantation and surgical aortic valve replacement in elderly patients with severe aortic stenosis and similar baseline electrocardiographic findings.
Bagur R; Rodés-Cabau J; Gurvitch R; Dumont É; Velianou JL; Manazzoni J; Toggweiler S; Cheung A; Ye J; Natarajan MK; Bainey KR; DeLarochellière R; Doyle D; Pibarot P; Voisine P; Côté M; Philippon F; Webb JG
JACC Cardiovasc Interv; 2012 May; 5(5):540-551. PubMed ID: 22625193
[TBL] [Abstract][Full Text] [Related]
10. Impact of a new conduction defect after transcatheter aortic valve implantation on left ventricular function.
Hoffmann R; Herpertz R; Lotfipour S; Aktug Ö; Brehmer K; Lehmacher W; Autschbach R; Marx N; Lotfi S
JACC Cardiovasc Interv; 2012 Dec; 5(12):1257-63. PubMed ID: 23257374
[TBL] [Abstract][Full Text] [Related]
11. Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis.
Nuis RJ; Van Mieghem NM; Schultz CJ; Tzikas A; Van der Boon RM; Maugenest AM; Cheng J; Piazza N; van Domburg RT; Serruys PW; de Jaegere PP
Eur Heart J; 2011 Aug; 32(16):2067-74. PubMed ID: 21622979
[TBL] [Abstract][Full Text] [Related]
12. Incidence and predictors of left bundle branch block after transcatheter aortic valve implantation.
Aktug Ö; Dohmen G; Brehmer K; Koos R; Altiok E; Deserno V; Herpertz R; Autschbach R; Marx N; Hoffmann R
Int J Cardiol; 2012 Sep; 160(1):26-30. PubMed ID: 21458085
[TBL] [Abstract][Full Text] [Related]
13. Clinical impact of persistent left bundle-branch block after transcatheter aortic valve implantation with CoreValve Revalving System.
Testa L; Latib A; De Marco F; De Carlo M; Agnifili M; Latini RA; Petronio AS; Ettori F; Poli A; De Servi S; Ramondo A; Napodano M; Klugmann S; Ussia GP; Tamburino C; Brambilla N; Colombo A; Bedogni F
Circulation; 2013 Mar; 127(12):1300-7. PubMed ID: 23443735
[TBL] [Abstract][Full Text] [Related]
14. Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve implantation.
Fraccaro C; Buja G; Tarantini G; Gasparetto V; Leoni L; Razzolini R; Corrado D; Bonato R; Basso C; Thiene G; Gerosa G; Isabella G; Iliceto S; Napodano M
Am J Cardiol; 2011 Mar; 107(5):747-54. PubMed ID: 21247519
[TBL] [Abstract][Full Text] [Related]
15. Trends in the occurrence of new conduction abnormalities after transcatheter aortic valve implantation.
van der Boon RM; Houthuizen P; Urena M; Poels TT; van Mieghem NM; Brueren GR; Altintas S; Nuis RJ; Serruys PW; van Garsse LA; van Domburg RT; Cabau JR; de Jaegere PP; Prinzen FW
Catheter Cardiovasc Interv; 2015 Apr; 85(5):E144-52. PubMed ID: 25504891
[TBL] [Abstract][Full Text] [Related]
16. Severe conduction defects requiring permanent pacemaker implantation in patients with a new-onset left bundle branch block after transcatheter aortic valve implantation.
Nijenhuis VJ; Van Dijk VF; Chaldoupi SM; Balt JC; Ten Berg JM
Europace; 2017 Jun; 19(6):1015-1021. PubMed ID: 28340150
[TBL] [Abstract][Full Text] [Related]
17. Late Electrocardiographic Changes in Patients With New-Onset Left Bundle Branch Block Following Transcatheter Aortic Valve Implantation.
Faroux L; Muntané-Carol G; Urena M; Nombela-Franco L; Amat-Santos I; Kleiman N; Munoz-Garcia A; Atienza F; Serra V; Deyell MW; Veiga-Fernandez G; Masson JB; Canadas-Godoy V; Himbert D; Fischer Q; Castrodeza J; Elizaga J; Pascual JF; Webb JG; de la Torre JM; Asmarats L; Pelletier-Beaumont E; Alméndarez M; Couture T; Philippon F; Rodes-Cabau J
Am J Cardiol; 2020 Mar; 125(5):795-802. PubMed ID: 31889524
[TBL] [Abstract][Full Text] [Related]
18. Patients without prolonged QRS after TAVI with CoreValve device do not experience high-degree atrio-ventricular block.
Mouillet G; Lellouche N; Lim P; Meguro K; Yamamoto M; Deux JF; Monin JL; Bergoënd E; Dubois-Randé JL; Teiger E
Catheter Cardiovasc Interv; 2013 Apr; 81(5):882-7. PubMed ID: 22972678
[TBL] [Abstract][Full Text] [Related]
19. Long-term clinical outcome of persistent left bundle branch block after transfemoral aortic valve implantation.
Keßler M; Gonska B; Seeger J; Rottbauer W; Wöhrle J
Catheter Cardiovasc Interv; 2019 Feb; 93(3):538-544. PubMed ID: 30298700
[TBL] [Abstract][Full Text] [Related]
20. Pacemaker dependency after transcatheter aortic valve implantation with the self-expanding Medtronic CoreValve System.
van der Boon RM; Van Mieghem NM; Theuns DA; Nuis RJ; Nauta ST; Serruys PW; Jordaens L; van Domburg RT; de Jaegere PP
Int J Cardiol; 2013 Sep; 168(2):1269-73. PubMed ID: 23295037
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]