These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 23044739)

  • 21. Effects of flow amplitudes on intraprong pressures during bubble versus ventilator-generated nasal continuous positive airway pressure in premature infants.
    Kahn DJ; Habib RH; Courtney SE
    Pediatrics; 2008 Nov; 122(5):1009-13. PubMed ID: 18977980
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Mechanical ventilator design and function: the trigger variable.
    Sassoon CS
    Respir Care; 1992 Sep; 37(9):1056-69. PubMed ID: 10145700
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Accuracy of automatic tube compensation in new-generation mechanical ventilators.
    Elsasser S; Guttmann J; Stocker R; Mols G; Priebe HJ; Haberthür C
    Crit Care Med; 2003 Nov; 31(11):2619-26. PubMed ID: 14605533
    [TBL] [Abstract][Full Text] [Related]  

  • 24. When pressure is positive: a literature review of the prehospital use of continuous positive airway pressure.
    Williams B; Boyle M; Robertson N; Giddings C
    Prehosp Disaster Med; 2013 Feb; 28(1):52-60. PubMed ID: 23140660
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Comparative studies of CPAP systems using a respiration simulator. I. Evaluation criteria].
    Brandl M; Lang M; Obermayer A
    Anaesthesist; 1986 Feb; 35(2):73-9. PubMed ID: 3516002
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Noninvasive respiratory support in neonates: a brief review.
    Sankaran K; Adegbite M
    Zhongguo Dang Dai Er Ke Za Zhi; 2012 Sep; 14(9):643-52. PubMed ID: 22989430
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Seven Ventilators Challenged With Leaks During Neonatal Nasal CPAP: An Experimental Pilot Study.
    Drevhammar T; Nilsson K; Zetterström H; Jonsson B
    Respir Care; 2015 Jul; 60(7):1000-6. PubMed ID: 25715346
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Pressure stability with CPAP devices: A bench evaluation.
    Louis B; Leroux K; Boucherie M; Isabey D; Grillier-Lanoir V; Fauroux B; Lofaso F
    Sleep Med; 2010 Jan; 11(1):96-9. PubMed ID: 19892594
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Delivery room continuous positive airway pressure/positive end-expiratory pressure in extremely low birth weight infants: a feasibility trial.
    Finer NN; Carlo WA; Duara S; Fanaroff AA; Donovan EF; Wright LL; Kandefer S; Poole WK;
    Pediatrics; 2004 Sep; 114(3):651-7. PubMed ID: 15342835
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Extubation outcome following a spontaneous breathing trial with automatic tube compensation versus continuous positive airway pressure.
    Cohen JD; Shapiro M; Grozovski E; Lev S; Fisher H; Singer P
    Crit Care Med; 2006 Mar; 34(3):682-6. PubMed ID: 16505653
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Randomised controlled cross-over comparison of continuous positive airway pressure through the Hamilton Galileo ventilator with a Dräger CF 800 device.
    Sutton PJ; Perkins CL; Giles SP; McAuley DF; Gao F
    Anaesthesia; 2005 Jan; 60(1):72-6. PubMed ID: 15601276
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Update on one-lung ventilation: the use of continuous positive airway pressure ventilation and positive end-expiratory pressure ventilation--clinical application.
    Grichnik KP; Shaw A
    Curr Opin Anaesthesiol; 2009 Feb; 22(1):23-30. PubMed ID: 19295290
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A comparison of the oxygen cost of breathing between a continuous-flow CPAP system and a demand-flow CPAP system.
    Henry WC; West GA; Wilson RS
    Respir Care; 1983 Oct; 28(10):1273-81. PubMed ID: 10315455
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Understanding the use of continuous oscillating positive airway pressure (bubble CPAP) to treat neonatal respiratory disease: an engineering approach.
    Manilal-Reddy PI; Al-Jumaily AM
    J Med Eng Technol; 2009; 33(3):214-22. PubMed ID: 19340692
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Biphasic positive airway pressure (BIPAP)--a new form of augmented ventilation].
    Baum M; Benzer H; Putensen C; Koller W; Putz G
    Anaesthesist; 1989 Sep; 38(9):452-8. PubMed ID: 2686487
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Very early surfactant without mandatory ventilation in premature infants treated with early continuous positive airway pressure: a randomized, controlled trial.
    Rojas MA; Lozano JM; Rojas MX; Laughon M; Bose CL; Rondon MA; Charry L; Bastidas JA; Perez LA; Rojas C; Ovalle O; Celis LA; Garcia-Harker J; Jaramillo ML;
    Pediatrics; 2009 Jan; 123(1):137-42. PubMed ID: 19117872
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The impact of imposed expiratory resistance in neonatal mechanical ventilation: a laboratory evaluation.
    DiBlasi RM; Salyer JW; Zignego JC; Redding GJ; Richardson CP
    Respir Care; 2008 Nov; 53(11):1450-60. PubMed ID: 18957147
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effects of expiratory flow resistance on inspiratory work of breathing.
    Banner MJ; Downs JB; Kirby RR; Smith RA; Boysen PG; Lampotang S
    Chest; 1988 Apr; 93(4):795-9. PubMed ID: 3280260
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Jet flow-regulated expiratory resistance to maintain constant CPAP during the entire respiratory phase.
    Nishimura M; Takezawa J; Imanaka H; Taenaka N; Yoshiya I
    Chest; 1989 Apr; 95(4):876-80. PubMed ID: 2647423
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Dangerous Pressurization and Inappropriate Alarms during Water Occlusion of the Expiratory Circuit of Commonly Used Infant Ventilators.
    Hinder M; Perdomo A; Tracy M
    PLoS One; 2016; 11(4):e0154034. PubMed ID: 27116224
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.