These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 23047141)

  • 21. MR angiography for detecting the artery of Adamkiewicz and its branching level from the aorta.
    Hyodoh H; Shirase R; Kawaharada N; Hyodoh K; Sato T; Onodera M; Aratani K; Hareyama M
    Magn Reson Med Sci; 2009; 8(4):159-64. PubMed ID: 20035124
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Microsurgical anatomy of the Adamkiewicz artery-anterior spinal artery junction.
    N'da HA; Chenin L; Capel C; Havet E; Le Gars D; Peltier J
    Surg Radiol Anat; 2016 Jul; 38(5):563-7. PubMed ID: 26627692
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Identifying the Adamkiewicz artery using 3-T time-resolved magnetic resonance angiography: its role in addition to multidetector computed tomography angiography.
    Takagi H; Ota H; Natsuaki Y; Komori Y; Ito K; Saiki Y; Takase K
    Jpn J Radiol; 2015 Dec; 33(12):749-56. PubMed ID: 26497024
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Novel strategy for thoracoabdomianl aortic aneurysm repair; intraoperative selective perfusion of the Adamkiewicz artery].
    Ohtsubo S; Furukawa K; Rikitake K; Okazaki Y; Sato M; Natsuaki M; Matsumoto K; Kato A; Kudo S; Itoh T
    Kyobu Geka; 2004 Apr; 57(4):285-90. PubMed ID: 15071861
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Spinal cord feeding arteries at MR angiography for thoracoscopic spinal surgery: feasibility study and implications for surgical approach.
    Nijenhuis RJ; Leiner T; Cornips EM; Wilmink JT; Jacobs MJ; van Engelshoven JM; Backes WH
    Radiology; 2004 Nov; 233(2):541-7. PubMed ID: 15358852
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Magnetic resonance angiography and neuromonitoring to assess spinal cord blood supply in thoracic and thoracoabdominal aortic aneurysm surgery.
    Nijenhuis RJ; Jacobs MJ; Schurink GW; Kessels AG; van Engelshoven JM; Backes WH
    J Vasc Surg; 2007 Jan; 45(1):71-7; discussion 77-8. PubMed ID: 17210385
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Combined use of adamkiewicz artery demonstration and motor-evoked potentials in descending and thoracoabdominal repair.
    Ogino H; Sasaki H; Minatoya K; Matsuda H; Yamada N; Kitamura S
    Ann Thorac Surg; 2006 Aug; 82(2):592-6. PubMed ID: 16863770
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Preoperative spinal cord arteriography in aneurysmal disease of the descending thoracic and thoracoabdominal aorta: preliminary results in 45 patients.
    Kieffer E; Richard T; Chiras J; Godet G; Cormier E
    Ann Vasc Surg; 1989 Jan; 3(1):34-46. PubMed ID: 2713230
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparison of magnetic resonance with computed tomography angiography for preoperative localization of the Adamkiewicz artery in thoracoabdominal aortic aneurysm patients.
    Nijenhuis RJ; Jacobs MJ; Jaspers K; Reinders M; van Engelshoven JM; Leiner T; Backes WH
    J Vasc Surg; 2007 Apr; 45(4):677-85. PubMed ID: 17306951
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Low-tube-voltage CT assessment of Adamkiewicz artery: Precise comparison between 100-kVp- and 120-kVp protocols.
    Kubota Y; Yokota H; Mukai H; Horikoshi T; Ota J; Okafuji Y; Ueda H; Matsumiya G; Uno T
    Eur J Radiol; 2019 Feb; 111():56-61. PubMed ID: 30691665
    [TBL] [Abstract][Full Text] [Related]  

  • 31. The Initial Exploration of Adamkiewicz Artery Computed Tomographic Angiography With Monochromatic Reconstruction of Gemstone Spectral Imaging.
    Yin XR; Xia W; Yao ZW; He HJ; Feng XY
    J Comput Assist Tomogr; 2016; 40(5):820-6. PubMed ID: 27224228
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Thoracoabdominal or descending aortic aneurysm repair after preoperative demonstration of the Adamkiewicz artery by magnetic resonance angiography.
    Kawaharada N; Morishita K; Fukada J; Yamada A; Muraki S; Hyodoh H; Abe T
    Eur J Cardiothorac Surg; 2002 Jun; 21(6):970-4. PubMed ID: 12048072
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Multidetector CT angiography using a dual-head power injector and bolus tracking for the diagnosis of aortic aneurysms at reduced contrast material dosage.
    Hirai N; Imakita S; Tanaka R; Higashi M; Nishino T; Naito H; Ito K
    Acad Radiol; 2006 Jun; 13(6):694-700. PubMed ID: 16679271
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Detectability of the artery of Adamkiewicz on computed tomography angiography of the aorta by using ultra-high-resolution computed tomography.
    Hino T; Kamitani T; Sagiyama K; Yamasaki Y; Matsuura Y; Tsutsui S; Sakai Y; Furuyama T; Yabuuchi H
    Jpn J Radiol; 2020 Jul; 38(7):658-665. PubMed ID: 32170567
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Systematic evaluation of collateral pathways to the artery of Adamkiewicz using computed tomography.
    Yoshioka K; Tanaka R; Takagi H; Ueyama Y; Sugawara T; Chiba T; Arakita K; Schuijf JD
    Eur J Cardiothorac Surg; 2018 Jul; 54(1):19-25. PubMed ID: 29370354
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Three-dimensional image of Adamkiewicz artery detected by using multidetector CT: preoperative assessment of thoraco-abdominal aortic aneurysm].
    Yokoyama H; Sanada S; Doi H; Ohno T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2006 May; 62(5):715-7. PubMed ID: 16767830
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Presurgical localization of the artery of Adamkiewicz with time-resolved 3.0-T MR angiography.
    Bley TA; Duffek CC; François CJ; Schiebler ML; Acher CW; Mell M; Grist TM; Reeder SB
    Radiology; 2010 Jun; 255(3):873-81. PubMed ID: 20501724
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Demonstration of the artery of Adamkiewicz at multi- detector row helical CT.
    Takase K; Sawamura Y; Igarashi K; Chiba Y; Haga K; Saito H; Takahashi S
    Radiology; 2002 Apr; 223(1):39-45. PubMed ID: 11930046
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of Slow-Infusion Magnetic Resonance Angiography with Sequential K-Space Filling and Computed Tomography Angiography to Detect the Adamkiewicz Artery.
    Mizushima S; Mine T; Abe M; Sekine T; Fujii M; Hayashi H; Ikeda S; Happoh S; Takashi Y; Kumita SI
    Ann Vasc Surg; 2023 Aug; 94():369-377. PubMed ID: 36868460
    [TBL] [Abstract][Full Text] [Related]  

  • 40. MDCT angiography of the spinal vasculature and the artery of Adamkiewicz.
    Boll DT; Bulow H; Blackham KA; Aschoff AJ; Schmitz BL
    AJR Am J Roentgenol; 2006 Oct; 187(4):1054-60. PubMed ID: 16985157
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.